GESTRA TRG 5-6 User manual

1
EN
English
Temperature Sensor
TRG 5-6..
Original Installation Instructions
818597-05

2
Contents
Page
Important notes
Usage for the intended purpose...............................................................................................................4
Function..................................................................................................................................................4
Safety note..............................................................................................................................................4
Directives and standards
Pressure Equipment Directive 2014/34/EU..............................................................................................5
Functional Safety acc. to IEC 61508 ........................................................................................................5
DIN EN 14597 .........................................................................................................................................5
Approvals for Marine Applications ...........................................................................................................5
ATEX (Atmosphère Explosible) .................................................................................................................5
Note on the Declaration of Conformity / Declaration by the Manufacturer ..........................................5
Technical data
TRG 5-63, TRG 5-64, TRG 5-65, TRG 5-66, TRG 5-67 and TRG 5-68........................................................6
TRG 5-63, TRG 5-64, TRG 5-65, TRG 5-66, TRG 5-67 and TRG 5-68........................................................7
Scope of supply ......................................................................................................................................7
Tolerances of the precision resistor according to EN 60751....................................................................8
Name plate / marking .............................................................................................................................8
Installation
Dimensions TRG 5-63 and TRG 5-64.......................................................................................................9
Key .........................................................................................................................................................9
Dimensions TRG 5-65, TRG 5-66, TRG 5-67 and TRG 5-68....................................................................10
Key .......................................................................................................................................................10
TRG 5-63 and TRG 5-64........................................................................................................................11
TRG 5-65, TRG 5-66, TRG 5-67 and TRG 5-68.......................................................................................11
Tools.....................................................................................................................................................11
Examples of installation ........................................................................................................................12
Electrical connection
TRG 5-63, TRG 5-64, TRG 5-65, TRG 5-66, TRG 5-67 and TRG 5-68, terminal box.................................13
Key .......................................................................................................................................................13

3
Contents
Page
Electrical connection
Connecting the temperature sensor.......................................................................................................14
Connecting the measuring element.......................................................................................................14
Wiring diagram for temperature sensor .................................................................................................15
Tools.....................................................................................................................................................15
Key .......................................................................................................................................................15
Troubleshooting
Indication, diagnosis and remedy ..........................................................................................................16
Measure the fluid temperature ..............................................................................................................16
Safety note............................................................................................................................................17
Replacing the temperature measuring element .....................................................................................17
Spare Parts ...........................................................................................................................................17
Removing and disposing of the temperature sensor
Removing and disposing of temperature sensor TRG 5-63 or TRG 5-64.................................................18
- continued -

4
Important notes
Usage for the intended purpose
The temperature sensor TRG 5-6.. in conjunction with temperature switches TRS 5-50, TRS 5-52 or
with temperature transmitter TRV 5-40 are designed for measuring temperatures in steam or hot water.
Danger
The temperature sensors TRG 5-63 or TRG 5-64 are screwed into vessels or pipes. When
loosening the temperature sensor steam or hot water might escape! This presents the risk
of severe scalding all over the body!
It is therefore essential not to dismantle the temperature sensor unless the boiler pressure
is verified to be 0 bar.
The temperature sensor becomes hot during operation.
Risk of severe burns to hands and arms.
Before carrying out installation and maintenance work make sure that the equipment is cold.
Safety note
Safety temperature limiters/monitors
are items of equipment with safety function (PED) and must only be
installed, wired and commissioned by qualified and competent staff.
Retrofitting and maintenance work must only be performed by qualified staff who - through adequate
training - have achieved a recognised level of competence.
The temperature sensors TRG 5-63, TRG 5-65, TRG 5-66 and TRG 5-67 feature one integrated platinum
resistance thermometer Pt 100 to EN 60751 each.
The temperature sensors TRG 5-64 and TRG 5-68 are equipped with two platinum resistance
thermometers Pt 100 for the connection of additional indicating equipment.
The ohmic resistance of the resistance thermometer changes as a function of temperature. If a
constant current is applied, the voltage produced by the change of resistance is measured and further
processed in the temperature switch or temperature transmitter.
The temperature sensor can be used as measuring transducer for
na safety temperature monitor/limiter in conjunction with temperature transmitter TRV 5-40 and
control unit NRS 1-40.1
na temperature monitor/controller in conjunction with temperature transmitter TRV 5-40 and
switching controller TRS 5-40
na safety temperature monitor/limiter in conjunction with temperature switch TRS 5-50
na temperature monitor in conjunction with temperature switch TRS 5-52
Function
Attention
The name plate specifies the technical features of the equipment. Note that any piece of
equipment without its specific name plate must neither be commissioned nor operated.

5
Directives and standards
Pressure Equipment Directive 2014/68/EU
Safety temperature limiters/monitors are safety accessories as defined in the Pressure Equipment
Directive (PED). The temperature switch TRS 5-50 and the temperature transmitter TRV 5-40 (together
with control unit NRS 1-40.1) in conjunction with temperature sensors TRG 5-6.. are EC type approved
according to EN 12952/EN 12953. These Directives state, among other things, the requirements made on
limiting systems and equipment for steam boiler plants and (pressurised) hot-water installations.
Functional Safety acc. to IEC 61508
The temperature switch TRS 5-50 and the temperature transmitter TRV 5-40 (together with control unit
NRS 1-40.1) in conjunction with temperature sensors TRG 5-6.. are certified to IEC 61508.
This standard
describes the functional safety of safety-related electrical/electronic/programmable electronic
systems.
The equipment combination TRG 5-6.. + TRS 5-50 corresponds to a type B subsystem with Safety
Integrity Level (SIL) 3.
The combination TRG 5-6.. + TRV 5-40 (with NRS 1-40.1) corresponds to a type B subsystem with
Safety Integrity Level (SIL) 2.
According to the European Directive 2014/34/EU the equipment must not be used in explosion-risk
areas.
ATEX (Atmosphère Explosible)
DIN EN 14597
The temperature sensor TRG 5-6.. in conjunction with temperature switches TRS 5-50 and TRS 5-52
or in conjunction with temperature transmitter TRV 5-40 (together with control unit NRS 1-40.1)
is type
approved to DIN EN 14597.
DIN EN 14597 describes and specifies the requirements made on (safety) temperature limiters/monitors.
Approvals for Marine Applications
The temperature sensor TRG 5-6.. in conjunction with
temperature switch TRS 5-50
is approved for
marine applications.
Note on the Declaration of Conformity / Declaration by the Manufacturer
For details on the conformity of our equipment according to the European Directives see our Declaration
of Conformity or our Declaration of Manufacturer.
The current Declaration of Conformity / Declaration of Manufacturer are available in the Internet under
www.gestra.com/documents or can be requested from us.

6
Technical data
TRG 5-63, TRG 5-64, TRG 5-65, TRG 5-66, TRG 5-67 and TRG 5-68
Measuring element (3-wire connection)
TRG 5-63
1 x Pt 100 to EN 60751, class A*)
TRG 5-64
2 x Pt 100 to EN 60751, class A*)
TRG 5-65, TRG 5-66
1 x Pt 100 to EN 60751, up to 300°C class A*), > 300°C class B*)
TRG 5-67
1 x Pt 100 to EN 60751, class B*)
TRG 5-68
2 x Pt 100 to EN 60751, class B*)
Service pressure, service temperature
TRG 5-63, TRG 5-64
Nominal length 100, 160, 250 mm
36 bar at 251°C
Nominal length 400 mm
18 bar at 400°C
TRG 5-65, TRG 5-66
160 bar at 345°C
120 bar at 540°C
TRG 5-67, TRG 5-68
150 bar at 600°C
Admissible flow velocity
TRG 5-63, TRG 5-64
Air 25 m/s
Superheated steam 25 m/s
Water 3 m/s
Nominal length 400 mm
Water 2.4 m/s
TRG 5-65, TRG 5-66, TRG 5-67, TRG 5-68
Air 60 m/s
Superheated steam 60 m/s
Water 5 m/s
Mechanical connection
TRG 5-63, TRG 5-64
Thread G ½ A, ISO 228
TRG 5-65, TRG 5-66, TRG 5-67, TRG 5-68
Welding sleeve
Protection tube, welding sleeve
Dimensions see pages 9, 10

7
Materials
TRG 5-63, TRG 5-64
Protection tube 1.4571, X6CrNiMoTi17122
TRG 5-65, TRG 5-66
Welding sleeve 1.7335
TRG 5-67, TRG 5-68
Welding sleeve 1.4961
Ambient temperature at terminal box
Max. 70°C
Protection
IP 66 to DIN EN 60529
Cable entry / Electrical connection
EMC cable gland with integral cable clamp M 20x1.5
Weight
TRG 5-63, TRG 5-64
approx. 0.5 kg
TRG 5-65, TRG 5-66
approx. 0.6 kg
TRG 5-67, TRG 5-68
approx. 1 kg
Approvals:
EC Type approval PED Pressure Equipment Directive 2014/68/EU,
EN 12952-11, EN 12953-09: Requirements made on limiting equipment
for boilers.
Functional Safety acc. to EN 61508: Functional safety of safety-related electrical/electronic/
SIL 3 programmable/electronic systems
Type approval DIN EN 14597:
Requirements made on safety temperature limiters/monitors
DIN Registration number (see name plate)
TRG 5-6../ TRV 5-40, NRS 1-40.1 DIN safety temp. monitor (/limiter)
STW(STB) 117908
TRG 5-6../ TRV 5-40, NRS 5-40 DIN temp. controller/monitor (TR/TW) 1182
TRG 5-6../ TRS 5-50 DIN safety temp. monitor (/limiter) STW(STB) 1230
TRG 5-6../ TRS 5-52 DIN temp. monitor (TW) 1232
Marine applications In accordance with classification society, GL 47399-12 HH
TRG 5-63, TRG 5-64, TRG 5-65, TRG 5-66, TRG 5-67 and TRG 5-68
Technical data
Scope of supply
TRG 5-63, TRG 5-64, TRG 5-65, TRG 5-66, TRG 5-67 and TRG 5-68
1 Temperature sensor
1 Installation manual
- continued -
- continued -

8
Technical data
Name plate / marking
Fig. 1
Equipment designation
Nominal
length
Application
range
Manufacturer
CE Marking
Material number
*) Class A and B, admissible tolerances of the precision resistor
Tolerances of the precision resistor according to EN 60751
Temperature in °C
Admissible deviation in °C
Admissible deviation in Ω
±2
±1.5
±1
±0.5
±4
±3
±2
±1
-200 -100 0 100 200 300 400 500 600 700 800
Class B °C
Class A °C
Class B Ω
Class A Ω
TRG 5-63
0525
L: 100
36 bar / 251°C
STW-STB 117908,1230;TW 1182,1232
392938
Münchener Str. 77 D-28215 BremenGESTRA AG
1x Pt 100
Klasse A
1.4571 IP 65
G
/
12
Measuring element
DIN Registration number
Material number Protection Mechanical
connection Disposal note
- continued -

9
Installation
Dimensions TRG 5-63 and TRG 5-64
Fig. 2
84120
15
∅26
∅9
∅9
1
[mm]
2
[mm]
100 30
160 30
250 30
400 30
27 mm A. F.
G½ A, ISO 228
Fig. 3
Ra 3.2
Ra 12.5
G½ A, ISO 228
∅26
0.5
1Length of protection tube
2Temperature-sensitive length
Key
3Joint ring ∅ 13 x 26
4Sealing surface
4
4
3
27
1
2

10
5
[mm]
6
[mm]
7
[mm]
8
[mm]
9
[mm]
0
[mm]
TRG 5-65 115 30 25 18 40 9
TRG 5-66 140 30 25 18 65 9
TRG 5-67 200 30 25 24 65 12.5
TRG 5-68 200 30 25 24 65 12.5
Installation
Dimensions TRG 5-65, TRG 5-66, TRG 5-67 and TRG 5-68
Fig. 4
84140
8
∅11
7
6
17/24 A. F.
0
Key
5Length of welding sleeve
6Temperature-sensitive length
7Threaded part
8 Diameter of welding sleeve
9Cone-shaped part
0Tip of cone-shaped part
- continued -
5
9
Table of contents
Popular Temperature Controllers manuals by other brands

SMC Networks
SMC Networks Thermo-con INR-244-639 Operation manual

eltherm
eltherm Ex-TC It Series operating instructions

Omron
Omron C200H-TV Series Operation manual

industrie technik
industrie technik CA1 instructions

KRAL
KRAL EET 32 operating instructions

dixell
dixell XR420C Installing and operating instructions