GEZE Powerturn (1-leaf) User manual

Powerturn
Valid for variants:
Powerturn (1-leaf/2-leaf)
Powerturn F (1-leaf)
Powerturn F-IS (2-leaf)
Powerturn F/R (1-leaf/2-leaf)
Powerturn IS/TS (2-leaf)
Powerturn F-IS/TS (2-leaf)
Powerturn F/R-IS/TS (2-leaf)
Original operating instructions
EN User manual
156539-03

Powerturn
2
Contents
1 Introduction...............................................................................................................................................................3
1.1 Symbols and illustrations ..............................................................................................................................................................................3
1.2 Product liability .................................................................................................................................................................................................3
1.3 Special cases.......................................................................................................................................................................................................3
1.4 More detailed information............................................................................................................................................................................3
1.5 Terms .....................................................................................................................................................................................................................4
2 Fundamental safety precautions .......................................................................................................................6
3 Description.................................................................................................................................................................7
3.1 Types of installation and versions ..............................................................................................................................................................7
3.2 Set-up....................................................................................................................................................................................................................7
3.3 Overview of the modes of operation........................................................................................................................................................8
3.4 Operating elements.........................................................................................................................................................................................8
3.4.1 Operating modes push button with operating modes display......................................................................................................8
3.4.2 Mechanical programme switch MPS (optional)....................................................................................................................................9
3.4.3 Display program switch (optional).............................................................................................................................................................9
3.5 Door in normal operation .......................................................................................................................................................................... 10
4 Operation .................................................................................................................................................................11
4.1 Selecting the mode of operation.............................................................................................................................................................11
4.1.1 Selecting the mode of operation using the operating modes push button...........................................................................11
4.1.2 Selecting the mode of operation at the mechanical programme switch MPS.......................................................................12
4.1.3 Selecting the mode of operation using the display programme switch...................................................................................12
5 Troubleshooting.....................................................................................................................................................13
6 Cleaning and maintenance................................................................................................................................14
6.1 Cleaning .............................................................................................................................................................................................................14
6.2 Maintenance.....................................................................................................................................................................................................14
6.3 Inspection by an expert ...............................................................................................................................................................................14
7 Technical data .........................................................................................................................................................15

Powerturn
3
Introduction
1 Introduction
1.1 Symbols and illustrations
Warning notices
Warning notices are used in these instructions to warn you of personal injury and property damage.
XAlways read and observe these warning notices.
XObserve all the measures that are marked with the warning symbol and warning word.
Warning
symbol
Warning word Meaning
CAUTION Danger for individuals.
Non-compliance can result in minor to medium injuries.
Further symbols and means of representation
Important information and technical notes are highlighted to explain correct operation.
Symbol Meaning
means “important note”;
information about avoiding property damage
means “additional Information”
The user's attention should be drawn to important addition information. There is no danger to persons or
property, but it is particularly useful to read the additional information carefully.
XSymbol for an action: This means you have to do something.
XIf there are several actions to be taken, keep to the given order.
1.2 Product liability
In compliance with the liability of the manufacturer for his products as dened in the German “Product Liability
Act”, compliance with the information contained in this brochure (product information and intended use, misuse,
product performance, product maintenance, obligations to provide information and instructions) must be en-
sured. Failure to comply releases the manufacturer from his statutory liability.
1.3 Special cases
In certain cases, deviations from the information given in this user manual may occur. Examples:
àspecial wiring
àspecial function settings (parameters)
àspecial software
XPlease contact the service technician responsible for further information.
1.4 More detailed information
Information about commissioning and service can be found in the following documents:
àPowerturn wiring diagram
àPowerturn installation instructions

Powerturn
4
Introduction
1.5 Terms
Term Explanation
Hinge side The side of the door where the hinges from which the door leaf is suspended are locat-
ed. Usually that side of the door located in the opening direction.
Opposite hinge side The side of the door facing the hinge side. Usually that side of the door located in the
direction of closing movement.
Active leaf The active leaf of a double-leaf door. When someone passes through the door, the
active leaf must open as the rst door leaf and close as the last door leaf.
Passive leaf The secondary leaf of a double-leaf door. When the door is used, the passive leaf may
not open until the active leaf has left the closing position and must close again as the
rst door leaf.
Activation device inside (KI) Push button, switch or movement detector for activating the door drive.
The activation device is located within the room enclosed by the door.
Activation function in the AUTOMATIC and EXIT ONLY modes of operation.
The activation device does not have any function in the NIGHT/OFF mode of operation.
Activation device outside (KA) Push button, switch or movement detector for activating the door drive.
The activation device is located outside the room enclosed by the door.
Activation function in the AUTOMATIC mode of operation. The activation device does
not have any function in the EXIT ONLY and NIGHT/OFF modes of operation.
Activation device
authorised (KB)
Access control function (for example key switch or card reader) used by authorised
persons to activate the door drive.
The activation function is active in the AUTOMATIC, EXIT ONLY and NIGHT/OFF modes
of operation.
Activation device with current
impulse function
Push button for opening and closing the door. Activation function only in the AUTO-
MATIC and EXIT ONLY modes of operation. The door is opened automatically when the
button is rst pressed and closed again automatically when the button is pressed the
second time. The function can be activated during commissioning by setting parame-
ters using the display programme switch, ST 220 or GEZEconnects. If the activation de-
vice is connected to the passive leaf control system by means of the “current impulse”
function, both door leaves open when activated, even when the passive leaf control
system is deactivated.
Push&Go When the door is pressed manually out of the closing position with an activated
Push & Go function in the AUTOMATIC operating mode, the door opens automatically
as soon as a specic adjustable opening angle is exceeded.
Opening safety sensor (SIO) Presence detector (e.g. active infrared light switch) for protecting the swinging range
of the door in the opening direction. As a rule the sensor is located on the hinge side of
the door on the door leaf.
Closing safety sensor (SIS) Presence detector (for example active infrared light switch) for protecting the swinging
range of the door in the closing direction. As a rule the sensor is located on the oppo-
site hinge side of the door leaf.
Emergency stop Self-locking switch with which immediate stopping of the door drive can be triggered
in case of danger. The door drive remains in its current position until the user releases
the emergency stop switch again, thus terminating the emergency stop situation.
Low-energy function The GEZE Powerturn can be used as a low-energy drive.
In low-energy function the force needed for opening and closing the door is reduced
to 67N and the opening and closing time is reduced. This lowers the danger of a per-
son bumping into the moving leaf.
If people who are particularly vulnerable pass through the door, special measures must
be taken to eliminate the contact hazard (e.g. use of open/ closing safety sensor).

Powerturn
5
Introduction
Term Explanation
Closing sequence control Electrical closing sequence control
In normal operation of double-leaf door drives, the closing sequence of the door leaves
is controlled by the control units of the door drives, with the passive leaf being closed
rst. The active leaf remains in the open position until the passive leaf has reached the
closed position, then the active leaf begins to close.
Integrated closing sequence control (-IS)
The closing sequence is controlled mechanically in the case of a power failure at dou-
ble-leaf door systems with Powerturn F-IS and Powerturn F-IS/TS. The door leaves are
closed by means of the power storage device of the drives, with the active leaf being
kept open by the integrated mechanical closing sequence control. When the passive
leaf has reached the closed position, it releases the active leaf by means of the mechan-
ical elements of the closing sequence control so that it can also close completely.
Electric strike Electric strike fail safe
Available as AC or DC electric strike version. When the door drive is activated, the
electric strike is switched on by the control unit of the door drive provided the door is
in the closed position. The electric strike remains activated until the door has left the
closed position.
Electric strike fail secure
DC electric strike version. The electric strike is switched o when the door drive is acti-
vated provided the door is in the closed position. The electric strike remains switched
o until the door has left the closed position.
Bar message feedback The bar message feedback function is a contact integrated in the door catch that is
activated when the door is locked mechanically by the tie bolt of the door lock. It sig-
nals to the control unit that the door is locked mechanically and can therefore not be
opened by the door drive. In this case the control unit ignores the control commands
of all the activation devices.
Reset Button for restarting the drive after the operating voltage has been switched on or
after a re alarm has been terminated. When the button is pressed, the self-retention
integrated in the drive is activated, causing the drive to be activated.
Latching function When the door is closed in a de-energised state, the door leaf is impeded by the lock
latch of the electric strike. To make sure the door can pass the lock latch safely during
closing, an integrated limit switch is actuated in the drive once a specic opening an-
gle has been reached, reducing the braking strength. The door accelerates and closes
into the lock at increased speed. In an energised state, this function is regulated by the
drive control unit.
Door closer mode In automatic mode (normal mode) the automatic swing door automatic drive can
behave like a door closer. This means that closing is torque-controlled. This closing
torque can be adjusted and adapted to the respective passage situation.
Servo operation If servo operation is used, the swing door drive supports manual passage through
moment of force (Siehe Review-Datei von November). The support moment of force
and the support period can be set for this support.

Powerturn
6
Fundamental safety precautions
2 Fundamental safety precautions
For the user
Carefully read and abide by this user manual before commissioning the door. Always observe the following safety
instructions:
àOperating, maintenance and repair conditions specied by GEZE must be observed.
àThe commissioning, prescribed installation, maintenance and repair work must be performed by properly
trained personnel authorised by GEZE.
àThe connection to the mains voltage must be made by a professional electrician.
àNo changes may be made to the system without prior agreement from GEZE.
àGEZE shall assume no liability for damage caused by unauthorised changes to the system.
àThe owner is responsible for safe operation of the system.
àHave a service technician check the safe operation of the system at regular intervals.
àShould safety devices be misaligned, thus preventing them from fullling their intended purpose, further
operation is not permissible. The service technician must be informed without delay.
àMake sure that the safety stickers are attached visibly to any glass leaves and are in a legible state.
àProtect the programme switch against unauthorised access.
àDanger of injury by sharp edges on the drive when removing the cover
àDanger of injury by parts hanging down
àThis appliance can be used by children aged from 8 years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe way and understand the hazards involved.
àChildren shall not play with the appliance.
àCleaning and user maintenance shall not be made by children without supervision.
For the service technician
àGEZE does not accept any warranty for combinations with third-party products.
àOnly combine third-party products with original parts following agreement by GEZE. Furthermore, only origi-
nal GEZE parts may be used for repair and maintenance work.
àThe power connection and safety earth conductor test must be carried out in accordance DIN VDE 0100-610.
àUse a customer-accessible 16-A overload cut-out that disconnects the system from the power supply as the
line-side disconnecting device.

Powerturn
7
Description
3 Description
3.1 Types of installation and versions
àThe door drive unit can be mounted in transom mounting at the lintel or in door leaf installation on the door leaf.
àThe door drive is available as 1-leaf or 2-leaf version.
àThe Powerturn F-IS and Powerturn F-IS/TS systems can only be mounted in transom installation.
3.2 Set-up
The door system shown is only a schematic diagram.
For technical reasons, we cannot show all of the possibilities here.
The operating elements can be arranged individually.
Example: Door drive Powerturn, 1-leaf, transom installation
1 Door drive unit
2 Link arm or roller guide rail
3 Smoke switch control unit 2)
4 Activation device outside (KA) (optional)
5 Activation device authorised (KB) (optional)
6 Smoke switch 2)
7 Activation device inside (KI) (optional)
8 Programme switch (optional)
9 Key switch for enabling the programme switch
(optional)
10 Emergency stop button (optional)
11 Circuit breaker “CLOSE DOOR” 2)
12 Electric strike (optional)
13 Door handle with door lock (on site)
14 Inside building
15 Outside building
16 Closing safety sensor (SIS) (optional)
17 Door transmission cable (optional)
18 Opening safety sensor (SIO) (optional)
19 Reset switch
20 Socket for service adapter ST 220 and Bluetooth adapter
21 Operating modes push button with operating
modes display
2) optional, in conjunction with Powerturn F

Powerturn
8
Description
3.3 Overview of the modes of operation
The following modes of operation can be set on the Powerturn:
àAutomatic mode
àExit only
àHold open
àNight mode
àOFF
Mode of operation MPS/MPS-ST* DPS** Explanatory notes
Key Display
Automatic aU Door opens and closes again.
The inside and outside activation devices are active.
Refer also to Chapter 3.5.
àOpening of 2 leaves When the keys are pressed simultaneously, the
mode of operation changes between 1-leaf open-
ing and 2-leaf opening.
àOpening of 1 leaf On the DPS the LED is lit in 1-leaf operation.
Exit only ls Door only opens and closes if someone exits.
Only the inside activation devices are active.
Hold open DO Door remains open.
Night mode Na Door opens and closes only when activated using
the key switch The inside and outside activation
devices are inactive.
OFF OFF OFF Of Door is enabled and can be moved by hand. The
inside and outside activation devices are inactive.
* mechanical programme switch (MPS)/mechanical program switch with integrated key switch (MPS-ST)
** display programme switch
3.4 Operating elements
The modes of operation can be set using the following operating elements:
àOperating modes push button (21) on the door drive (refer to chapter 3.4.1)
àMechanical programme switch MPS with/without integrated key switch (optional) (see chapter 3.4.2)
àDisplay programme switch (optional) (see chapter 3.4.3)
3.4.1 Operating modes push button with operating modes display
The operating mode on the door drive can be selected using the operating modes push button (21). The operat-
ing modes display (21) lights up in the colour of the current mode of operation:
Operating modes displays
Mode of operation Colour of the operating modes display (21)
O –
Night mode red
Exit only white
Automatic green
Hold open blue
Information and fault displays
State Colour of the operating modes display (21)
The control has not been taught yellow (light on permanently)
The control has not been initialised yet lights up in the colour of the current mode of operation periodically inter-
rupted by two brief ashing impulses (1Hz)
One or more faults are queued ashes quickly (10Hz) in the colour of the current mode of operation
The operating modes push button is deactivated
operating modes display is switched o
In the O mode of operation, there is no fault display on the operating modes display (21).

Powerturn
9
Description
3.4.2 Mechanical programme switch MPS (optional)
àCan be connected in addition to the operating modes push button (21).
At the mechanical programme switch MPS, the mode of operation for
the system is selected and the corresponding programme is displayed.
The mechanical programme switch is accessible for everyone without
a key switch.
Mechanical programme switch MPS
With the mechanical programme switch MPS-ST, selection of the
modes of operation is disabled if the key provided has been removed.
Mechanical programme switch MPS-ST
with integrated key switch
3.4.3 Display program switch (optional)
àAdditionally, it can be connected to the internal operating modes push button.
If a dot appears in the bottom right-hand part of the display,
maintenance is due.
OFF
Display programme switch
If a dot appears in the middle of the display, the door has not
yet been fully initialised after the mains voltage has been
switched on.
Initialisation is carried out automatically when the drive opens
and closes the door.

Powerturn
10
Description
3.5 Door in normal operation
In normal operation, the door is automatically opened and closed.
When Powerturn IS/TS is used, only the active leaf opens automatically. The passive leaf has to be opened manually.
What happens? What does the door do?
An activation device (push button, switch or movement
detector) is triggered.
Door opens, waits the hold-open time and then closes.
Closing safety sensor (SIS) is triggered when the door is
open (e.g. light switch).
Door remains open.
Closing safety sensor (SIS) is triggered while the door is
closing.
The door immediately opens again or stops depending on
the parameter setting.
Opening safety sensor (SIO) is triggered while door is
opening.
The door stops and remains in position until the end of
activation (door opens) or until the end of the hold-open
time (door closes).
Opening safety sensor (SIO) is triggered when the door is
closed.
Door remains closed.
A person moves toward the opened door and a movement
detector is activated.
Door remains open.
A person moves toward the closing door and a movement
detector is activated.
Door reopens immediately.
Door contacts an obstruction when opening. The opening
safety sensor has not been activated.
Door stops, waits and attempts again to move to the open
position at a reduced speed.
Then the door closes again.
Door contacts an obstruction when closing. The closing
safety sensor has not been activated.
Door reopens immediately, waits the hold-open time and
then closes at a reduced speed.
When door closer mode is used with the closing safety
sensor deactivated, the drive presses against the obstacle
with the force set.
Additional door functions
Which switch/button? What does the switch/button do?
Emergency stop button The door stops immediately (in every mode of operation)
and holds the position until the emergency stop button is
unlocked.
Key switch of the display programme switch If a key-operated switch is connected to the display pro-
gramme switch, the operation of the display programme
switch can be locked or released with it.
Activation device authorised (KB) (e.g. outside key switch) Door opens once and closes after the hold-open time. The
set mode of operation is retained.
Activation device with radio board Door opens once and closes after the hold-open time. The
set mode of operation is retained.
If the key in radio channel 1 is pressed for longer than 5s,
the controller changes to the DO mode of operation. After
the key has been pressed again for at least 5s, the control
changes back to the AU mode of operation.
Switch function The automated door can be activated using the switch
function.
Normal switch function:
àSwitch contact opens the door and the door remains in
the open position.
àSwitch contact closes the door.
Switch function with hold-open time:
àSwitch contact opens the door.
àSwitch contact closes the door or the door starts to
close after the hold-open time.

Powerturn
11
Operation
Which switch/button? What does the switch/button do?
Double push button In the case of 2-leaf drives, a button with a double function
can be connected via a congurable push button. This
means that 1-leaf or 2-leaf opening is possible by pressing
the push button.
If the push button is pressed once, only the active leaf
opens and closes after the hold-open time has expired. If
the button is pressed twice within 1.5 s, both leaves open
and close after the double leaf hold-open time has expired.
Emergency lock When the emergency lock is used, a switch can close the
1- or 2-leaf system immediately. The doors close with the
set force and without sensor strips and obstacle detection.
There is an increased risk of injury.
WC control The door opens after the elbow switch on the outside of
the toilet has been pressed, and closes automatically after
the set hold-open time has passed.
When the push button is activated inside the toilet cabin, the
system is switched to the exit only mode of operation, which
means the outer push button no longer opens the door. At
the same time, the lights indicate that the toilet is occupied.
The electric strike is supplied with current, preventing
manual opening of the door from outside.
Activating the “inner” push button again or through manu-
al opening from inside, the WC function (exit only mode of
operation) is cancelled and the drive switched back to the
automatic mode of operation.
The ‘occupied’ displays and lights go out.
4 Operation
The set parameters of the drive functions may only be modied by a service technician.
4.1 Selecting the mode of operation
4.1.1 Selecting the mode of operation using the operating modes push button
The operating modes push button can be deactivated by a service technician.
Changing the mode of operation (with single-leaf doors or active leaf)
XPress the operating modes push button (21) with operating modes
display briey.
The operating modes display (2) immediately switches one mode of op-
eration further. The drive itself does not change the mode of operation to
the new mode of operation until 1s after the last button has been pressed.
Operating modes sequence, with the colour of the operating modes
display in brackets:
… OFF (–) Night mode (red) Exit only (white)
Automatic (green) Hold open (blue) OFF (–) Night mode (red) …
Thanks to the 1s delay it is possible to change the mode of operation
from automatic through hold open to night mode without the door
opening in the hold open setting.
Changing the mode of operation (with passive leaf)
XPress the operating modes push button (21) with operating modes display briey.
The drive on the passive leaf is switched on and o.
If the drive is switched on, the operating modes display lights up in the colour of the mode of operation (see chapter3.4.1).
If the drive is switched o, the operating modes display does not light up.

Powerturn
12
Operation
4.1.2 Selecting the mode of operation at the mechanical programme switch MPS
With the programme switch MPS
XTurn the rotary switch (22) to the required mode of operation.
The mode of operation is set.
22
Mechanical programme switch MPS
With the programme switch MPS-ST (key switch
Operation of the mechanical programme switch MPS-ST is only
possible with the supplied key (23).
XInsert the key (23) into the mechanical programme switch MPS-ST.
XTurn the key rotary switch (24) to the required mode of operation.
The mode of operation is set.
XRemove the key.
The mechanical programme switch MPS-ST locked.
Mechanical programme switch MPS-ST
with integrated key switch
4.1.3 Selecting the mode of operation using the display programme switch
XTouch the required mode of operation on the display
programme switch.
The mode of operation is set and indicated on the display (25).
OFF
25
Display programme switch
Fault messages on the display
If a fault occurs in the door system, it is displayed on the display programme switch about every 10 seconds.
XRead o the number of the fault message, note it down and notify the service technician.

Powerturn
13
Troubleshooting
5 Troubleshooting
Problem Cause Remedy
Door only opens and closes
slowly
Obstruction in travel path XRemove obstruction and check door leaf
for ease of movement
XHave the door close completely once;
after detection of an obstruction the door
moves at a safe speed until the complete
closing procedure has been completed.
Closing safety sensor (SIS) soiled XClean the closing safety sensor
XHave the door close completely once;
after detection of an obstruction the door
moves at a safe speed until the complete
closing procedure has been completed.
Closing safety sensor (SIS) misaligned or
defective
XNotify a service technician
Door opens and closes
constantly
Obstruction in travel path XClear the obstruction
Light beams or reections, e.g. reective
oor, falling rain
XCheck detection eld of movement
detector
Misaligned movement detector XCheck detection eld of movement
detector
Door only opens a crack Obstruction in travel path XRemove obstruction and check door leaf
for ease of movement
Door does not open Obstruction in travel path XRemove obstruction and check door leaf
for ease of movement
Movement detector misaligned or defective
(outside)
XCheck the movement detector, notify a
service technician if necessary
Emergency stop activated XUnlock emergency stop
“Night” operating mode XSelect a dierent mode of operation
“Exit only”operating mode XSelect “Automatic” operating mode
Door locked mechanically XUnlock the door
Electric strike does not release XNotify a service technician
Fire alarm active (only Powerturn F) XPress the Reset switch
Drive defective XNotify a service technician
Door does not close
After 4 min. of permanent
activation by the safety
sensor, the Powerturn/
Powerturn F automatically
closes the door
automatically in low-
energy mode)
Closing safety sensor (SIS) soiled XClean the closing safety sensor (SIS)
Closing safety sensor (SIS) misaligned or
defective
XNotify a service technician
Obstruction in travel path XRemove obstruction and check door leaf
for ease of movement
Movement detector triggers constantly XCheck the movement detector, notify a
service technician if necessary
“Hold open” mode of operation XSelect a dierent mode of operation
Current impulse push button function
controls
XTerminate activation by activating the
push button again
Display programme switch
cannot be operated
Display programme switch is disabled XActivate key switch for release
Display programme switch defective XNotify a service technician
Display programme switch
displays 88
Connection between display programme
switch and control unit faulty
XNotify a service technician
Display programme switch or control unit
defective
XNotify a service technician
Display programme switch
is dark
Mains power failure XCheck mains fuse
Connection between display programme
switch and control unit faulty
XNotify a service technician
Display programme switch or control unit
defective
XNotify a service technician
Display of fault messages
on the display programme
switch
Fault in the door system XNote fault messages. Up to 10 dierent
fault messages can occur in succession.
The display changes about every 10seconds.
XNotify a service technician

Powerturn
14
Cleaning and maintenance
6 Cleaning and maintenance
6.1 Cleaning
CAUTION!
Danger of injury due to impact and crushing!
XSet the mode of operation to OFF.
XSecure door leaves against accidental movement before carrying out cleaning work.
What is to be cleaned? How is it to be cleaned?
Closing safety sensor (SIS) (e.g. light switch) XWipe with damp cloth
Glass surfaces XWipe with a cold vinegar/water mixture; then dry.
Stainless surfaces XWipe with soft cloth
Painted surfaces XWipe with water and soap
Anodised surfaces XWipe with non-alkaline potassium soap (pH value 5.5…7)
Display programme switch XWipe with soft cloth. Do not use a cleaning agent
6.2 Maintenance
The owner must ensure that the system is working perfectly. To guarantee perfect operation, the door system
must be serviced regularly by a service technician.
Maintenance must be carried out at least once a year or according to the maintenance display on the display
programme switch.
Installation, maintenance and repair work must be performed by properly trained personnel authorised by GEZE.
If a dot appears in the bottom right-hand part of the display, maintenance is due.
XNotify a service technician.
The maintenance display lights up after the specied calendar period or number of opening cycles, depending
on what occurs rst:
Powerturn (F) 1 year or 500,000 cycles
GEZE oers maintenance contracts with the following services:
àInspection of xing elements for rm t
àPerformance of miscellaneous adjustment work
àPerformance of operational checks
àChecking all the safety and control equipment of the door system
àLubrication of all the moveable parts
6.3 Inspection by an expert
In compliance with the“Guidelines for windows, doors and gates”(ASR A1.7 and GUV 16.10) Section 6, power-operat-
ed doors must be inspected for safety by a trained professional before initial commissioning and at least once a year.
GEZE oers the following services:
Inspection and operational checks of all safety and control equipment in compliance with the requirements in the
test log for power-operated windows, doors and gates; Sliding doors and sliding gates ZH 1/580.2 edition.

Powerturn
15
Technical data
7 Technical data
Opening time: 3 … 25s
Closing time: 5 … 25s
Mains voltage 230 V AC –15 %, +10 %
Frequency 50 Hz
Protection rating I
Capacity rating 200 W
Mains connection Fixed connection (installation cable or drip loop)
Primary fuse –
Secondary fuse 10 A slow-blow, 5×20mm
Secondary voltage (transformer) 33 VAC (46 V DC)
Control voltage for external compo-
nents
24 VDC ±10 %
Output current control voltage 24 V 1200mA permanently
1800mA briey (2s, duty ratio 30%)
Fuse protection <24V 2.5 A; reversible
Temperature range –15…+50 °C
IP rating IP30

Germany
GEZE GmbH
Branch Oce South-West
Tel. +49 (0) 7152 203 594
Email: leonberg.de@geze.com
GEZE GmbH
Branch Oce South-East
Tel. +49 (0) 7152 203 6440
Email: [email protected]
GEZE GmbH
Branch Oce East
Tel. +49 (0) 7152 203 6840
Email: [email protected]
GEZE GmbH
Branch Oce Central/Luxembourg
Tel. +49 (0) 7152 203 6888
Email: [email protected]
GEZE GmbH
Branch Oce West
Tel. +49 (0) 7152 203 6770
Email: duesseldorf[email protected]
GEZE GmbH
Branch Oce North
Tel. +49 (0) 7152 203 6600
Email: hamburg.de@geze.com
GEZE Service GmbH
Tel. +49 (0) 1802 923392
Email: service-info[email protected]
Austria
GEZE Austria
Email: [email protected]
www.geze.at
Baltic States
GEZE GmbH Baltic States oce
Email: o[email protected]
www.geze.com
Benelux
GEZE Benelux B.V.
Email: [email protected]
www.geze.be
www.geze.nl
Bulgaria
GEZE Bulgaria - Trade
Email: o[email protected]
www.geze.bg
China
GEZE Industries (Tianjin) Co., Ltd.
Email: [email protected]
www.geze.com.cn
GEZE Industries (Tianjin) Co., Ltd.
Branch Oce Shanghai
Email: [email protected]
www.geze.com.cn
GEZE Industries (Tianjin) Co., Ltd.
Branch Oce Guangzhou
Email: [email protected]
www.geze.com.cn
GEZE Industries (Tianjin) Co., Ltd.
Branch Oce Beijing
Email: [email protected]
www.geze.com.cn
France
GEZE France S.A.R.L.
Email: france.fr@geze.com
www.geze.fr
Hungary
GEZE Hungary Kft.
Email: oce-hungar[email protected]
www.geze.hu
Iberia
GEZE Iberia S.R.L.
Email: info@geze.es
www.geze.es
India
GEZE India Private Ltd.
Email: o[email protected]
www.geze.in
Italy
GEZE Italia S.r.l
Email: [email protected]
www.geze.it
GEZE Engineering Roma S.r.l
Email: roma@geze.biz
www.geze.it
Poland
GEZE Polska Sp.z o.o.
Email: geze.pl@geze.com
www.geze.pl
Romania
GEZE Romania S.R.L.
Email: o[email protected]
www.geze.ro
Russia
OOO GEZE RUS
Email: o[email protected]
www.geze.ru
Scandinavia – Sweden
GEZE Scandinavia AB
Email: sverige.se@geze.com
www.geze.se
Scandinavia – Norway
GEZE Scandinavia AB avd. Norge
Email: norge.se@geze.com
www.geze.no
Scandinavia – Denmark
GEZE Danmark
Email: [email protected]
www.geze.dk
Singapore
GEZE (Asia Pacic) Pte, Ltd.
Email: [email protected]om.sg
www.geze.com
South Africa
GEZE South Africa (Pty) Ltd.
Email: [email protected].za
www.geze.co.za
Switzerland
GEZE Schweiz AG
Email: schweiz.ch@geze.com
www.geze.ch
Turkey
GEZE Kapı ve Pencere Sistemleri
Email: o[email protected]
www.geze.com
Ukraine
LLC GEZE Ukraine
Email: oce-uk[email protected]om
www.geze.ua
United Arab Emirates/GCC
GEZE Middle East
Email: [email protected]om
www.geze.ae
United Kingdom
GEZE UK Ltd.
Email: info[email protected]
www.geze.com
GEZE GmbH
Reinhold-Vöster-Strasse 21-29
71229 Leonberg
Germany
Tel.: +49 (0) 7152 2030
Fax.: +49 (0) 7152 203310
www.geze.com
This manual suits for next models
8
Table of contents