Giga-tronics GT-1000A User manual

Giga-tronics GT-1000A Microwave Power Amplifier
Operation Manual, Part Number 34672, Rev. C, March 2011
Operation Manual
GT-1000A Microwave Power Amplifier

Giga-tronics GT-1000A Microwave Power Amplifier
Page ii Operation Manual, Part Number 34672, Rev. C, March 2011
All technical data and specifications in this publication are subject to change without prior notice and do not
represent a commitment on the part of Giga-tronics, Incorporated.
© 2011 Giga-tronics Incorporated. All rights reserved. Printed in the U.S.A.
CONTACT INFORMATION
Giga-tronics, Incorporated
4650 Norris Canyon Road
San Ramon, California 94583
Telephone: 800.726.4442 (only within the United States)
925.328.4650
Fax: 925.328.4700
On the Internet: www.gigatronics.com
Warranty
Giga-tronics GT-1000A Series instruments are warranted against
defective materials and workmanship for one year from date of
shipment. Giga-tronics will at its option repair or replace
products that are proven defective during the warranty period.
This warranty DOES NOT cover damage resulting from improper
use, nor workmanship other than Giga-tronics service. There is
no implied warranty of fitness for a particular purpose, nor is
Giga-tronics liable for any consequential damages. Specification
and price change privileges are reserved by Giga-tronics.

Giga-tronics GT-1000A Microwave Power Amplifier
Operation Manual, Part Number 34672, Rev. C, March 2011 Page iii
Regulatory Compliance Information
This product complies with the essential requirements of the following applicable European Directives,
and carries the CE mark accordingly.
89/336/EEC and 73/23/EEC EMC Directive and Low Voltage Directive
EN61010-1 (1993) Electrical Safety
EN61326-1 (1997) EMC –Emissions and Immunity
Manufacturer’s Name: Manufacturer’s Address
Giga-tronics, Incorporated 4650 Norris Canyon Road
San Ramon, California 94583
U.S.A.
Type of Equipment: Model Series Number
Microwave Power Amplifier GT-1000A
Model Numbers:
Not applicable
Declaration of Conformity on file. Contact Giga-tronics at the following;
Giga-tronics, Incorporated
4650 Norris Canyon Road
San Ramon, California 94583
Telephone: 800.726.4442 (only within the United States)
925.328.4650
Fax: 925.328.4700

Giga-tronics GT-1000A Microwave Power Amplifier
Page iv Operation Manual, Part Number 34672, Rev. C, March 2011
Record of Changes to This Manual
Use the table below to maintain a permanent record of changes to this document. Replacement pages will be
issued as a TPCI (Technical Publication Change Instruction), and will be
TPCI Number
TPCI Issue Date
Date Entered
Comments

Giga-tronics GT-1000A Microwave Power Amplifier
Operation Manual, Part Number 34672, Rev. C, March 2011 Page v
Table of Contents
CHAPTER 1SAFETY AND MANUAL CONVENTIONS........................................................................................................ 1
1.1 Personal Safety Alert ....................................................................................................................................... 1
1.2 Equipment Safety Alert.................................................................................................................................... 1
1.3 Notes................................................................................................................................................................ 1
1.4 Before Applying Power .................................................................................................................................... 1
1.5 Electrical Safety Precautions ........................................................................................................................... 2
1.6 Important Operating Precautions ................................................................................................................... 2
CHAPTER 2INTRODUCTION .................................................................................................................................... 3
2.1 Overview.......................................................................................................................................................... 3
2.1.1 Features and Benefits of the GT-1000A Microwave Power Amplifier ..................................................... 3
2.3 Controls, Indicators, and Connectors .............................................................................................................. 4
2.3.1 GT-1000A Front Panel Description ........................................................................................................... 5
2.3.2 GT-1000A Rear Panel Description ............................................................................................................ 6
2.3.3 Replace the Fuse ...................................................................................................................................... 7
2.4 Receiving and Inspection................................................................................................................................. 8
2.5 Prepare the GT-1000A for Use ........................................................................................................................ 9
2.5.1 Cooling...................................................................................................................................................... 9
2.5.2 AC Power Requirements........................................................................................................................... 9
2.6 Shipping, Repair, and Calibration .................................................................................................................. 10
2.6.1 Shipping the GT-1000A........................................................................................................................... 10
2.6.2 Repairs.................................................................................................................................................... 10
2.6.3 Calibration .............................................................................................................................................. 10
CHAPTER 3OPERATE THE GT-1000A..................................................................................................................... 11
3.1 Operating Safety and Instructions................................................................................................................. 11
3.2 Operator’s Maintenance ............................................................................................................................... 12
3.2.1 Equipment and Materials ....................................................................................................................... 12
CHAPTER 4PERFORMANCE VERIFICATION................................................................................................................ 13
4.1 Specifications................................................................................................................................................. 13
4.2 Performance Verification .............................................................................................................................. 16
4.2.1 Equipment and Materials ....................................................................................................................... 16
4.2.2 GT-1000A Performance Verification Setup ............................................................................................ 16
APPENDIX AOPTIONS ......................................................................................................................................... 19

Giga-tronics GT-1000A Microwave Power Amplifier
Page vi Operation Manual, Part Number 34672, Rev. C, March 2011
List of Tables
Table 1: GT-1000A Front Panel Controls, Indicators, and Connections .................................................................... 5
Table 2: GT-1000A Rear Panel Controls, Indicators, and Connections ..................................................................... 6
Table 3: Replace the GT-1000A Line Fuse ................................................................................................................. 7
Table 4: Receiving and Inspection of the GT-1000A.................................................................................................. 8
Table 5: GT-1000A AC Power Specifications ............................................................................................................. 9
Table 6: Operate the GT-1000A............................................................................................................................... 11
Table 7: Cleaning the GT-1000A .............................................................................................................................. 12
Table 8: General Performance................................................................................................................................. 13
Table 9: GT-1000A RF Output Power ...................................................................................................................... 13
Table 10: Gain Flatness............................................................................................................................................ 14
Table 11: VSWR ....................................................................................................................................................... 14
Table 12: General Specifications ............................................................................................................................. 14
Table 13: AC Fuse .................................................................................................................................................... 15
Table 14: Additional Specifications ......................................................................................................................... 15
Table 15: GT-1000A Performance Verification Procedure...................................................................................... 17
Table 16: GT-1000A Performance Verification Datasheet ...................................................................................... 18
Table 17: GT-1000A Options ................................................................................................................................... 19
List of Figures
Figure 1: GT-1000A Front Panel ................................................................................................................................ 4
Figure 2: Front Panel Indicators ................................................................................................................................ 4
Figure 3: GT-1000A Rear Panel.................................................................................................................................. 4
Figure 4: GT-1000A Fuse Holder................................................................................................................................ 7
Figure 5: GT-1000A Performance Verification Setup .............................................................................................. 16

Giga-tronics GT-1000A Microwave Power Amplifier Safety and Manual Conventions
Operation Manual, Part Number 34672, Rev. C, March 2011 Page 1
Chapter 1 Safety and Manual Conventions
This manual contains conventions regarding safety and equipment usage as described below.
1.1 Personal Safety Alert
WARNING: Indicates a hazardous situation which, if not avoided, could result in death
or serious injury.
1.2 Equipment Safety Alert
CAUTION: Indicates a situation which can damage or adversely affect the GT-1000A or
associated equipment.
1.3 Notes
Notes are denoted and used as follows:
NOTE: Highlights or amplifies an essential operating or maintenance procedure, practice, condition or
statement.
Review this manual to become familiar with the instrument safety markings and instructions before operation.
This product is a Safety Class I instrument (provided with a protective earth terminal).
1.4 Before Applying Power
Verify that the product is set to match the available line voltage and the correct fuse is installed.
See Table 13 on page 15.
WARNING
!
CAUTION

Safety and Manual Conventions Giga-tronics GT-1000A Microwave Power Amplifier
Page 2 Operation Manual, Part Number 34672, Rev. C, March 2011
1.5 Electrical Safety Precautions
An uninterruptible safety earth ground must be provided from the main power source to the GT-1000A.
Any interruption of the protective ground conductor (internal or external to the instrument) or
disconnecting the protective earth terminal will cause a potential shock hazard that could result in personal
injury.
Grounding a single conductor of a two conductor outlet is insufficient protection. Additionally, verify that a
common ground exists between the unit under test, any additional test equipment, and this instrument
prior to energizing any unit.
Whenever it is likely that the protection has been impaired, the instrument must be removed from service
and secured against unintended operation.
If this instrument is to be energized via an autotransformer (for voltage reduction), ensure that the common
terminal is connected to neutral.
Servicing instructions are for use by service–trained personnel only. To avoid personal injury, do not perform
any service unless qualified to do so.
Adjustments described in the manual are performed with the unit energized and protective covers removed.
Energy available, at many points, may cause personal injury.
For continued protection against fire hazard, replace the line fuse only with a 250V fuse of the same current
rating and type. Do not use repaired fuses or short circuited fuse holders.
1.6 Important Operating Precautions
The GT-1000A Amplifier does not include an enable/disable feature to activate and deactivate the amplifier.
When connecting or disconnecting the output of the amplifier, ensure that the power switch of the amplifier
is in the OFF position.
The amplifier is capable of power output levels greater than 15 Watts. Devices connected to the output of
the amplifier must be rated to handle 25 Watts or higher. Exceeding the rated output power of a device will
result in permanent damage.
When connecting the amplifier to a transmitting device, observe all safety procedures to ensure that the
amplifier isn’t interfering with other systems in the area. High power microwaves can adversely affect power
sensitive instruments in the area of transmission.
Exercise precautions to avoid exposure to radiated microwave energy at all times.
CAUTION
WARNING
!

Giga-tronics GT-1000A Microwave Power Amplifier Introduction
Operation Manual, Part Number 34672, Rev. C, March 2011 Page 3
Chapter 2 Introduction
2.1 Overview
This chapter describes the controls, inputs/outputs, indicators, and basic function of the GT-1000A.
2.1.1 Features and Benefits of the GT-1000A Microwave Power Amplifier
Provides 10 Watts up to 8 GHz, and 5 Watts up to 20 GHz
Provides up to 40 dB of gain over 2 to 20 GHz
Incorporates the CAP Wireless patented Spatium™ spatial combining architecture solid-state amplifier. The
Spatium™ technology amplifier is based on a solid state parallel MMIC design with exceptionally wide
bandwidth and high power. The unique circuit topology is highly reliable, with performance that excels
where extremes of bandwidth and power are demanded.
Provides excellent pulse fidelity
Low intermodulation distortion
High linearity and superior gain flatness without the warm-up time, drift or aging issues of traveling wave
tube amplifiers (TWTA).
Low noise figure
Low harmonics and spurious content
Highly tolerant to load mismatch.

Introduction Giga-tronics GT-1000A Microwave Power Amplifier
Page 4 Operation Manual, Part Number 34672, Rev. C, March 2011
2.3 Controls, Indicators, and Connectors
The following pages describe all of the features shown in the Figure 1, Figure 2, and Figure 3 below.
Figure 1: GT-1000A Front Panel
Figure 2: Front Panel Indicators
Figure 3: GT-1000A Rear Panel

Giga-tronics GT-1000A Microwave Power Amplifier Introduction
Operation Manual, Part Number 34672, Rev. C, March 2011 Page 5
2.3.1 GT-1000A Front Panel Description
Table 1 describes the parts and functions of items on the front panel. Refer to Figure 1 on the previous page for
the location of the items on the front panel.
Table 1: GT-1000A Front Panel Controls, Indicators, and Connections
GT-1000A Front Panel Controls, Indicators, and Connections
Name
Function
Power On/Off button
Switches the AC power on and off.
Gain Control
Adjusts the gain of the amplifier.
The gain control has a range of about 10 dB.
RF Output (Option 04 Only; RF Output is
on the rear panel in Option 05)
Option 02: Type N female connector
Option 03: SMA female connector
RF Input (Option 04 Only; RF input is on
the rear panel in Option 05)
Indicators
FAN FAULT 1
Illuminated indicates the exhaust fan has stopped rotating.
The POWER ON LED remains illuminated, and the amplifier is
fully functional until a TEMPERATURE FAULT occurs.
TEMPERATURE FAULT 1
When illuminated, indicates the internal heat sink
temperature exceeds 75 °C.
All amplifier functions are disabled, the POWER ON indicator
extinguishes, and any other fault indicators are disabled. The
amplifier remains non-functional with the TEMPERATURE
FAULT indicator illuminated until the heat sink temperature
drops to less than 50 °C, at which point, the amplifier will
automatically restart.
MODULE FAULT 1
When illuminated, the MODULE FAULT LED indicates that
one or more amplification modules in the final stage of the
power amplifier are malfunctioning. The POWER ON indica-
tor remains illuminated, and the amplifier remains functional
at reduced capability and performance.
POWER ON
When illuminated, indicates AC power is applied and unit is
ready to function
1 If any fault occurs, switch off the instrument’s power at the front panel before investigating the cause
of the failure.

Introduction Giga-tronics GT-1000A Microwave Power Amplifier
Page 6 Operation Manual, Part Number 34672, Rev. C, March 2011
2.3.2 GT-1000A Rear Panel Description
Table 2 describes the parts and functions of items on the rear panel. Refer to Figure 3 on page 4 for the location
of the items on the rear panel.
Table 2: GT-1000A Rear Panel Controls, Indicators, and Connections
GT-1000A Rear Panel Controls, Indicators, and Connections
Name
Function
RF In (Option 05 only; the RF input is
located on the front panel in Option 04)
Option 02: Type N female connectors
Option 03: SMA female connectors
RF Out (Option 05 only; the RF output is
located on the front panel in Option 04)
Detector out (Option 01 only)
The output connector for the internal coupler/detector. This
output can be used for external ALC and power monitoring.
SMA (f), -1 Volt DC nominal detector output at 10 Watts RF
out, and nominally -250 mV at 1 Watt RF out, into high
impedance.
AC Input and fuse
Provides the AC power input and over-current protection for
the amplifier.
For fuse specifications at the AC voltage to be used for the
GT-1000A, see Table 13 on page 15.
NOTE: Instructions for replacing the fuse are located on page 7.
Serial number label
Provides important information about the GT-1000
microwave power amplifier.
A full description of the information on the serial number
label is provided below.
Serial Number Label Description
Descriptor
Type of Information
Code
This is a two-digit manufacturing code
Model
This identifies the model. This line is usually “GT-1000A.”
Serial
This is a seven-digit serial number, and provides a unique
identifier for each GT-1000A.
Options
When options have been included in the GT-1000A, one or
more two-digit numbers are listed on this line of the label.
For more information about options, see Appendix A on
page 19.
Config
Contains important unique configuration information.

Giga-tronics GT-1000A Microwave Power Amplifier Introduction
Operation Manual, Part Number 34672, Rev. C, March 2011 Page 7
2.3.3 Replace the Fuse
Follow the procedure in Table 3 below to replace the fuse.
Table 3: Replace the GT-1000A Line Fuse
Replace the GT-1000A Line Fuse
Step
Action
1.
Use the power switch on the front of the GT-1000A to switch the power OFF.
2.
On the rear of the GT-1000A, disconnect the AC line cord. The fuse compartment is located next to the
AC line cord socket.
3.
Remove the fuse as follows (see Figure below):
A) Use a small flat-blade screwdriver to pry open the fuse compartment.
B) Pull out the white fuse holder.
C) You can now remove the fuse from the fuse holder.
Figure 4: GT-1000A Fuse Holder
4.
Replace the fuse with a new fuse (see Table 13 on page 15 for selecting the fuse type).
Push the fuse holder in, and close the fuse compartment door.
5.
Plug the AC line cord into the rear of the GT-1000A and return the instrument to operation.
NOTE: If the GT-1000A continues to blow fuses, contact your local Giga-tronics sales representative or
the Giga-tronics factory for help to resolve the problem. See the contact information on the inside of the
front cover of this manual (page ii).
End of Procedure

Introduction Giga-tronics GT-1000A Microwave Power Amplifier
Page 8 Operation Manual, Part Number 34672, Rev. C, March 2011
2.4 Receiving and Inspection
Follow the procedure in Table 4 for receiving and inspecting the GT-1000A.
Table 4: Receiving and Inspection of the GT-1000A
Receiving and Inspection of the GT-1000A
Step
Action
1.
Before opening the shipping container, inspect it for any signs of damage.
If THERE IS evidence of damage; record the location and extent of the damage and contact the
shipper immediately to report the damage.
If there is NO EVIDENCE of damage; continue to the next step.
2.
Open the shipping container and inspect the contents for evidence of damage. The contents
should include any external, loose options and accessories, and the following:
Operation Manual
AC line cord
If any of the contents are damaged or missing, contact Giga-tronics immediately. Refer to the
Contact Information on the inside of the front cover of this manual.
End of procedure

Giga-tronics GT-1000A Microwave Power Amplifier Introduction
Operation Manual, Part Number 34672, Rev. C, March 2011 Page 9
2.5 Prepare the GT-1000A for Use
2.5.1 Cooling
The GT-1000A has an internal cooling fan. The air intake is located on the rear panel of the instrument. When
using the GT-1000A, ensure there are no obstructions to the flow of air into the instrument.
2.5.2 AC Power Requirements
Fuse Specifications: see Table 13 on page 15.
PROTECTIVE EARTH GROUND
This is a Safety Class 1 product (it includes a protective earth terminal). An
uninterruptible safety earth ground must be provided from the main AC power
source to the GT-1000A’s AC input connector. Observe the following:
If it is possible that the safety earth ground has been impaired, make the
GT-1000A inoperative and secure it against unintended operation.
If the GT-1000A will be powered through an autotransformer, verify that
the autotransformer’s common terminal is connected to the neutral
connector (the grounded side of the Mains supply).
MATCH FUSE TO INPUT AC VOLTAGE
Before applying AC power to the GT-1000A, check that the fuse in the rear of
the instrument (see Replace the Fuse on page 7) has a voltage rating that
matches the AC voltage.
AC Line Cord: All GT-1000A microwave synthesizers are supplied with a 6-foot, three-wire power cord with
three-terminal polarized plug with a safety ground. If a different power cord is used, it must not exceed 3 meters
(9 feet) in order to meet safety requirements.
Table 5 below describes the AC power requirements for the GT-1000A.
Table 5: GT-1000A AC Power Specifications
GT-1000A AC Power Specifications
Parameter
Specification
AC line voltage/frequency
85 to 264 Volts/47 to 63 Hz
NOTE: The GT-1000A automatically adjusts to operate at any voltage
within the voltage range above. No adjustment is necessary.
AC line power
450 VA maximum
WARNING
!
CAUTION

Introduction Giga-tronics GT-1000A Microwave Power Amplifier
Page 10 Operation Manual, Part Number 34672, Rev. C, March 2011
2.6 Shipping, Repair, and Calibration
2.6.1 Shipping the GT-1000A
If it is necessary to ship the GT-1000A, observe the following:
Use the best packaging materials available. If possible, reuse the original shipping container.
If the original shipping container is not available, use a strong carton (350lbs./sq.in. bursting strength) or a
wooden box.
Wrap the instrument in heavy paper or plastic before placing it into the shipping container.
Completely fill the areas on all sides of the instrument with packaging material. Take extra precaution to
protect the front and rear panels.
Seal the package with strong tape or metal bands. Mark the outside of the package clearly, and in bold type,
as follows:
FRAGILE —DELICATE INSTRUMENT
2.6.2 Repairs
The Giga-tronics GT-1000A microwave synthesizer is a robust instrument that has been designed and built for
years of trouble-free service. However, if you experience problems with the instrument, do the following:
1. Contact your local Giga-tronics sales office, or the factory, and be prepared to provide the model, serial
number, and any included options of your instrument, and a description of the problem. To contact the
factory directly, use the following information:
Contacting Giga-tronics Customer Service
Email
Telephone (within the United States)
800.726.4442
Telephone
925.328.4702
Fax
925.328.4702
2. If it is has been determined that you must ship the GT-1000A to the factory or a service center for
repair, you will be issued a Return Materials Authorization (RMA) number. Use the RMA number in all
correspondence regarding the repair.
3. Pack the GT-1000A for shipment as described in the previous section, and enclose all relevant
information regarding the problem.
4. Ship the GT-1000A to the address provided by Giga-tronics Customer Service.
2.6.3 Calibration
The GT-1000A is not a calibrated instrument. No specific calibration is required. For more information, contact
Giga-tronics.

Giga-tronics GT-1000A Microwave Power Amplifier Operation
Operation Manual, Part Number 34672, Rev. C, March 2011 Page 11
Chapter 3 Operate the GT-1000A
3.1 Operating Safety and Instructions
This section describes how to operate the GT-1000A Microwave Power Amplifier. Equipment and personal
safety information is also provided.
DO NOT EXCEED AN INPUT LEVEL OF 20 dBm INTO THE GT-1000A. EXCEEDING
THIS LEVEL CAN DAMAGE THE GT-1000A MICROWAVE POWER AMPLIFIER.
WHEN ENERGIZED, THE GT-1000A IS CAPABLE OF SUPPLYING POWER THAT
CAN CAUSE DAMAGE OR INJURY. TAKE THE FOLLOWING PRECAUTIONS TO
ENSURE SAFE SETUP AND OPERATION:
Verify that all cables, connectors, and equipment connected to the
GT-1000A are in good condition.
Do not make connections to equipment while the output of any item of
equipment is energized.
Table 6: Operate the GT-1000A
Operate the GT-1000A
Step
Action
1.
Verify that the output of the signal source driving the amplifier is NOT energized before
continuing to the next step.
2.
Connect the equipment to the GT-1000A according to your application.
NOTE: Verify all mating connectors are 50 Ohm, and that they are in good condition.
3.
Apply AC power to the GT-1000A by turning the front panel power switch ON. Observe that the
POWER ON indicator on the front panel illuminates (see Figure 1 on page 4).
4.
Verify that the output level of the signal source is set below 20 dBm.
5.
Energize the output of the signal source.
6.
If desired, adjust the GAIN knob on the front of the GT-1000A (in normal operation, the gain
adjust is set at maximum).
NOTE: Do not exceed the safe limits of the output power from the GT-1000A into the load. The
load should be rated for at least 30 Watts CW.
End of Procedure
CAUTION
WARNING
!

Operation Giga-tronics GT-1000A Microwave Power Amplifier
Page 12 Operation Manual, Part Number 34672, Rev. C, March 2011
3.2 Operator’s Maintenance
The only operator’s maintenance that the GT-1000A requires is regular cleaning of the air exhaust screen and
interior of the instrument. Both are important in order to maintain cooling airflow through the GT-1000A.
3.2.1 Equipment and Materials
Phillips screwdriver, small
Vacuum cleaner
Table 7: Cleaning the GT-1000A
Cleaning the GT-1000A
Step
Action
1.
Use the front panel power switch to de-energize the GT-1000A.
2.
Disconnect the AC power cord from the rear of the GT-1000A.
3.
Use a small Phillips screwdriver to remove the screws that secure both upper and lower covers
of the GT-1000A. Remove both covers.
4.
Use a vacuum cleaner to remove dust from the interior and from the screen in the air exhaust
port on the rear of the instrument.
NOTE: Do not bump the vacuum nozzle against any of the components inside the GT-1000A
during this procedure.
5.
Replace both covers onto the GT-1000A.
6.
Ensure that the GT-1000A operates correctly.
End of Procedure

Giga-tronics GT-1000A Microwave Power Amplifier Performance Verification
Operation Manual, Part Number 34672, Rev. C, March 2011 Page 13
Chapter 4 Performance Verification
This chapter is divided into two sections:
Specifications: this section contains all of the operating specifications that define the performance of
the GT-1000A.
Performance Verification: this section contains the test procedure that ensures that the GT-1000A
meets the specifications.
4.1 Specifications
Table 8: General Performance
General Performance
Parameter
Performance Limits
Conditions
Frequency range
2 GHz to 20 GHz
Gain
> 37 dB typical
Maximum gain adjust condition
Gain adjustment range
> 10 dB typical
Table 9: GT-1000A RF Output Power
GT-1000A RF Output Power
Frequency Range
Specification
2 to 8 GHz
+40 dBm (10 Watts) typical, +38.5 dBm (7 Watts) minimum
8 to 12 GHz
+38.5 dBm (7 Watts) typical, +37 dBm (5 Watts) minimum
12 to 18 GHz
+37 dBm (5 Watts) typical, +36 dBm (4 Watts) minimum
18 to 20 GHz
+37 dBm (5 Watts) typical
NOTES:
Output power is specified as minimum saturated power into a 50 Ohm load with +5 dBm input,
at 23 °C ± 5 °C.
Input power for normal operation should be limited to +20 dBm maximum.
Output power with Option 01 is decreased by 1 dB.
Output power with Option 05 is decreased by 1.25 dB.

Performance Verification Giga-tronics GT-1000A Microwave Power Amplifier
Page 14 Operation Manual, Part Number 34672, Rev. C, March 2011
Table 10: Gain Flatness
Gain Flatness
Frequency Range
Specification
2 GHz to 20 GHz
+/- 3.0 dB maximum
NOTES:
Nominal gain is 40 dB. Gain adjustment range is 10 dB minimum.
Gain flatness is specified as maximum variation with -5 dBm input and 50 Ohm load.
Table 11: VSWR
VSWR
Input
50 Ohms, 2:1 maximum
Output
50 Ohms, 2.7:1 maximum, 2.3:1 typical
Table 12: General Specifications
General Specifications
Parameter
Specification
Line Voltage
85 to 264 VAC, 47 to 63 Hz, Single Phase
Line Power
450 VA maximum
Operating Temperature
0 °C to +50 °C
Storage Temperature
-20 °C to +75 °C
Cooling
Forced air, field replaceable fans
Rack Height
3U (5.25 inches)
Dimensions 1
5.25 in. H x 17 in. W x 20 in. D (134 mm H x 432 mm W x 508 mm D)
Weight
< 35 lbs (< 16 kg)
Environmental
MIL-PRF-28800F, Class 3
Safety
EN61010
Emissions
EN61326
1 Dimensions with rack ears, 5.25 in. H x 19 in. W x 21 in. D (134 mm H x 483 mm W x 534 mm D)
Table of contents
Other Giga-tronics Amplifier manuals

Giga-tronics
Giga-tronics GT-1051B User manual

Giga-tronics
Giga-tronics GT-1050B User manual

Giga-tronics
Giga-tronics GT-1040A User manual

Giga-tronics
Giga-tronics GT-1020A User manual

Giga-tronics
Giga-tronics GT-1000B User manual

Giga-tronics
Giga-tronics GT-1050A User manual

Giga-tronics
Giga-tronics GT-1051A User manual