The 18si boiler is a wall mounted modulating boiler with
electronic ignition providing central heating.
The boiler is of the II2H3+ category for use with Natural Gas
(G20) as distributed in the United Kingdom, or Butane (G30),
Propane (G31) with the appropriate conversion kit.
Theboilerhasafanassistedbalancedfluewhichbothdischarges
the products of combustion to and draws the combustion air
from the outside of the room.
The boiler is suitable for top outlet flue connection only but can
befittedwithhorizontalflue,verticalflueortwin-pipeflue.Refer
toflueoptionsguideforfurtherinformation,thisisavailablefrom
your nearest stockist.
The central heating temperature is user adjustable from the
boiler control panel.
Domestic hot water demand always has priority over heating
demand.
Thepump,expansionvesselandassociatedsafetydevicesare
all fitted within the boiler.
The boiler can be installed against either an external wall or on
anadjacentinside wall,thatis,thefluesystemwill passdirectly
to the rear or to either side to the terminal fitted on the outside
wall face.
The installation must be carried out by a qualified registered
person in accordance with the relevant requirements of The
Building Regulations, The Water Byelaws, The Building
Standards (Scotland) Regulations and any applicable local
regulations.
Theseinstructions shouldbecarefullyfollowedforthesafeand
economical use of your boiler.
Electrical Supply
WARNING: This boiler must be earthed.
All system components shall be of an approved type and shall
be connected in accordance with the current issue of BS7671
and any applicable local regulations.
All external wiring between the appliance and the electrical
supplyandearthingrequirementsshallcomply with the current
IEE Regulations.
Connection of the boiler and system controls to the mains
supply must be through a common isolator and must be fused
3A, maximum. This method of connection must be by a fused
doublepoleisolatingswitch,withaminimumcontactseparation
of3mmonbothpoles. Theswitchshouldbereadilyaccessible
and preferably adjacent to the appliance. It should supply the
Introduction
appliance only and be easily identifiable as so doing.
Alternatively, an unswitched shuttered socket outlet and 3A
fused 3 pin plug, both to the current issue of BS1363 may be
usedprovidedthattheyarenotusedinaroomcontainingabath
or shower.
Wiringto the boilermust bePVC 85oC insulatedcable, not less
than 0.75mm2(24/0.20mm).
Gas safety (Installation and use) Regulations
Inyour interestsandthatofgassafety, itisthelawthatALL gas
appliances are installed and serviced by a qualified registered
person in accordance with the above regulations.
Gas leak or fault
Ifagasleakorfaultexistsorissuspected,turntheboileroffand
consult the local gas supply company or your installation/
service company.
Air in the heating system
Persistent air in the heating system may indicate leaks in the
systemorcorrosiontakingplace.CallyourInstallation/Servicing
company.
Overheating safety
Intheeventofaproblem,theoverheatingsafetydevicescause
safety shutdown of the boiler. If this happens, call your
Installation/Servicing company.
Boiler controls
Thecontrolpanel,locatedatthelowerfrontoftheboilercasing,
see diagram 1, allows the boiler to be started, shut down,
controlled and monitored during use.
Flue
Do not obstruct the outside terminal of the flue.
Ancillary equipment
A range of flue accessories are available including vertical
flues, twin-pipe flues, bends etc.
For further information contact your supplier.
Controls and lighting
Your 18si
boiler has been factory configured to operate at the
heart of an existing installation. However, because many
installations are specially designed, do not hesitate to contact
your installer who will be able to ensure that you get the best
performance from your installation, by adjusting the heating
circuit's maximum output or temperature.
Once these settings have been made, you can still adjust the
temperature to suit your needs.
Central heating adjustment
The selector switch enables you to vary the temperature of the
water in the central heating circuit from the minimum setting
(approx. 38˚C) up to the maximum temperature ( approx.
87˚C)setbyyourinstaller. Mostofthetime,themidpositionwill
meetyourneedsbuttheselectorshouldbemovednearertothe
maximum setting in very cold weather when your home is not
reaching the required temperature.