GLX GLS-4-MOD User manual

GLX LED STAGE 4 MANUAL
1
GLS-4-MOD
owners manual

GLX LED STAGE 4 MANUAL
2
Thanks for choosing the GLS-4-MOD lighting system. In order to make the best use of your LED
SYSTEM, please read the following carefully.
Important notes
1. Read these instructions.
2. Keep these instructions.
3. Do not use the GLS-4-MOD near water.
4. Clean only with dry cloth.
5. Install in accordance with the manufacturer’s instructions.
6. Do not block any ventilation openings.
7. To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.
8. Protect the power cord from being walked on or being pinched.
9. Unplug this apparatus when unused for long periods of time.
There are no user serviceable parts inside. All servicing has to be done by qualified service personnel.
Servicing is required when the GLS-4-MOD has been damaged in any way, such as when the power
supply cord or plug is damaged, when objects have fallen onto the GLS-4-MOD, when it has been
exposed to rain or moisture, or when the GLS-4-MOD does not operate normally.
Warning: damages caused by the disregard of this user manual are not subject to warranty.
Installation of the GLS-4-MOD
The GLX Lighting LED stage 4 modular led system holds:
4 seperate spots
1 PCB module with display
1 controller
Connect the spots and the controller to the module and plug in the power cord. The GLS-4-MOD starts
running in automatic mode. The spots and the module can be placed on a crossbar, lighting stand or
truss. Please note: for overhead rigging in public or industrial areas, a series of safety instructions have
to be followed that this manual can only give in part.
Main connection
The device must only be connected in compliance with the IEC standards. The electric installation must
be equipped with a Residual Current Device (RCD) with a maximum fault current of 30mA. Lighting
effects must never be connected to dimming packs.
Operation
After you power up the GLS-4-MOD, the LED’s start running and the display lights up. The device has
two operating modes; it can be operated in sound controlled or in DMX-controlled mode.
You can choose the desired mode via the button MENU, UP and DOWN:
When the display shows A*** you can choose the desired DMX address via the UP or DOWN buttons.
When the display shows *512 the device is in DMX mode. To switch to sound controlled mode, press
the DOWN button.
When the display shows *SND the device is in sound controlled mode. To switch to DMX mode, press
the UP button.
When the display shows S** you can choose the desired speed of the internal programs. Default is 51;
for increasing speed press the DOWN button, for decreasing speed press the UP button.

GLX LED STAGE 4 MANUAL
3
DMX controlled operation
You can control the spots individually via your DMX controller.
DMX-512 connection
Only use a stereo shielded cable with 3-pin XLR-connectors in order to connect the controller with the
fixture or one fixture with another.
Master - slave operation
The Master - slave operation enables several devices to be synchronized and controlled by one master
device. On the rear panel of the GLS-4-MOD module you can find an XLR socket, which can be used
for connecting several devices. Choose the device which is to control the effects (master). Connect the
OUT jack with the IN of the next device. Set the master device to SOUND mode and set each slave
device to the same DMX address.
Operation via controller
Connect the controller with the GLS-4-MOD via the 5-pin connection cable with plug.
Controller functions
Switch 1 Preset:
1 X press = white
2 X press = red
3 X press = green
4 X press = blue
5 X press = cyan
6 X press = yellow
7 X press = violet
8 X press = color change every second in a continuous loop
9 X press = color fade every 3 seconds in a continuous loop
Switch 2 Sound
Switch 3 Freeze
Switch 4 Blackout
To discontinue operation of the controller, press switch 1 and 4 simultaneously, then release both
switches simultaneously.
Cleaning and maintenance
Make sure that:
1. All screws used for installing the devices or parts of the device have to be tightly connected and must
not be corroded.
2. There must not be any deformations of the housings, fixations and installation spots (ceiling,
suspension, trussing)
3. The electric power supply cable must not show any damages, (e.g. porous cables) or sediments.
Further instructions depending on the installation spot and usage have to be adhered by a skilled
installer and any safety problems have to be removed. Disconnect from mains before starting
maintenance operation.
We recommend frequent cleaning of the device. Please use a soft lint-free and moistened cloth. Never
use alcohol or solvents!

GLX LED STAGE 4 MANUAL
4
Replacing the fuse
Only replace the fuse by a fuse of the same type and rating.
Step 1: Open the fuse holder on the rear panel of the module with a fitting screw driver.
Step 2: Remove the old fuse from the fuseholder.
Step 3: Install the new fuse in the fuseholder
Step 4: Remount the fuseholder in the housing
Before replacing the fuse, unplug the GLS-4-MOD.
Technical specifications
Power supply: 220-250V AC, 50-60 Hz~
Power consumption: 70W
Number of DMX channels: 15
DMX-512 connection: 3 pin XLR
Number of 10mm LEDs: 432
Beam angle: 25º
Sound-control: Via built-in microphone
Maximum ambient temperature Ta: 45ºC
Maximum housing temperature TB (steady state) 60ºC
Min.distance from flammable surfaces: 0.50m
Min.distance to lighted object: 0.10m
Fuse: F 2A, 250V
Packing Dimensions (LxWxH): 136 X 41 X 19,5
Weight: 8,5kg

GLX LED STAGE 4 MANUAL
5
Channels
Channel 1 - Internal programs, auto mode and sound controlled mode
Value Function
000-009 Off
010-029 Program 1
030-049 Program 2
050-059 Program 3
070-089 Program 4
090-109 Program 5
110-129 Program 6
130-149 Program 7
150-169 Program 8
170-189 Program 9
190-209 Program 10
210-229 Program 11
230-249 Auto Mode: Internal Programs
250-255 Sound controlled Mode
Channel 2 - Master Dimmer Channel 3 - Strobe
Value Function Value Function
000-009 Off 000-009 Off
010-255 Dimming from 0 – 100% 010-255 Flash with increasing speed
Channel 4 – spot 1 RED Channel 5 – spot 1 GREEN
Value Function Value Function
000-255 Dimming from 0 - 100 % 000-255 Dimming from 0 - 100 %
Channel 6 – spot 1 BLUE Channel 7 – spot 2 RED
Value Function Value Function
000-255 Dimming from 0 - 100 % 000-255 Dimming from 0 - 100 %
Channel 8 – spot 2 GREEN Channel 9 – spot 2 BLUE
Value Function Value Function
000-255 Dimming from 0 - 100 % 000-255 Dimming from 0 - 100 %
Channel 10 – spot 3 RED Channel 11 – spot 3 GREEN
Value Function Value Function
000-255 Dimming from 0 - 100 % 000-255 Dimming from 0 - 100 %
Channel 12 – spot 3 BLUE Channel 13 – spot 4 RED
Value Function Value Function
000-255 Dimming from 0 - 100 % 000-255 Dimming from 0 - 100 %
Channel 14 – spot 4 GREEN Channel 15 – spot 4 BLUE
Value Function Value Function
000-255 Dimming from 0 - 100 % 000-255 Dimming from 0 - 100 %
Table of contents
Other GLX Floodlight manuals
Popular Floodlight manuals by other brands

Acclaim Lighting
Acclaim Lighting LFL2M Installation and wiring instructions

Lightmaxx
Lightmaxx STARDUST user manual

Bayco
Bayco Night Stick NSR-2482 operating instructions

Sealey
Sealey LED18WFL instructions

Flex
Flex Hosedown Series installation instructions

WE-EF
WE-EF FLC250 Installation and maintenance instructions