GO Industries Adam Pumps TECH FLOW 3C Setup guide

Adam Pumps S.p.A.
Soc. con Socio Unico
via della resistenza 46/48 - 41011 Campogalliano (MO) ITALIA
Tel +39 059 528128 - Fax +39 059 528437
UM001
06/2020 - rev. 06
TECH FLOW 3C/4C
MAT FLOW 3C/4C
R-FLOW 3C/4C
ITALIANO
(lingua originale)
ENGLISH
(translation of original instructions)
IT
EN

The undersigned:
ADAM PUMPS S.p.a. Soc. con Socio Unico
Via della Resistenza, 46/48
41011, Campogalliano (MO), ITALY
DECLARES
that the equipment described:
Description: mechanical Meter
Models: TECH FLOW, MAT FLOW, R-FLOW
Year of manufacture: see the production date on the label afxed to the product
It is subjected to the following checks and calibrations: factory calibration, leak test, functional check.
This declaration does not exempt the installer or user from carrying out the appropriate checks and calibration to obtain the
declared precision ± 1% when testing the system.
ADAM PUMPS reserves the right to change the testing process described at any time and without prior notication.
Device not suitable for measuring products for sale to the public, their use in relation to third parties is prohibited
The documentation is available to the relevant authority, against a justied request, from ADAM PUMPS S.p.a. Soc. con Socio
Unico or by sending a request to: info@adampumps.com
The person authorised to compile the technical le and draw up the declaration is Davide Stassi as legal representative
The use and maintenance manual must be carefully stored near the machine in an environment protected
against humidity and heat. The manual must accompany the machine if sold. It is prohibited to damage,
modify or remove any part of the manual.
USE AND MAINTENANCE MANUAL
Machine: DIESEL FUEL METERS
Models: TECH FLOW 3C-4C, MAT FLOW 3C-4C, R-FLOW 3C-4C
Place and date of the document
Campogalliano, 28/05/2020
The legal representative
Month Year
FAC-SIMILE
TABLE OF CONTENTS
1 - GENERAL WARNINGS
2 - SAFETY INSTRUCTIONS
2.1 Safety measures
2.2 First aid
2.3 Protective devices
2.4 Packaging
2.5 Contents
3 - OPERATING CONDITIONS3.1
Environmental conditions
3.2 Allowed fluids / Forbidden fluids
3.3 Meter orientation
4 - INSTALLATION
4.1 General information
4.2 Mechanical
5 - CALIBRATION
5.1 Definitions
5.2 Calibration procedure
6 - TROUBLESHOOTING
7 - MAINTENANCE
7.1 Cleaning
8 - DEMOLITION AND DISPOSAL
9 - WARRANTY
10 - TECHNICAL SUPPORT
EN

EN
2 - SAFETY
2.1 - Safety Measures
1 - GENERAL WARNINGS
IMPORTANT: It is essential to have understood the entire instruction manual before
performing any operation so as to safeguard the operator and to avoid potential product damage.
Storing the manual: This manual must be kept intact and fully legible. The end user and the skilled
technicians authorised with installation and maintenance of the product in question must be able to consult it at all
times.
Reproduction rights: This manual is the property of ADAM PUMPS S.p.a. Soc. con Socio Unico , which is
the sole owner of all rights provided for by applicable law, including without limitation copyright rules. All rights
under these rules belong to ADAM PUMPS S.p.a. Soc. con Socio Unico : reproduction, even partial, of this
manual, its publication, modication, transcription, public disclosure, distribution, marketing in any form, translation
and/or development, loan, or any other activity reserved by law to ADAM PUMPS S.p.a. Soc. con Socio Unico
CAUTION: Live equipment. Contact between the power supply and the liquid to be pumped must
be prevented at all costs. Connect all equipment in the work area to the earthing system.
Immediately stop operation in the event of electrostatic discharges or if you feel a shock. Do not use
this device until the problem has been identied and duly solved.
IMPROPER USE OF THE PRODUCT
Improper use can result in serious injury or death. Do not operate the unit when fatigued or under the inuence of
alcohol or drugs. Do not leave the work area while the product is powered or under pressure.
Turn all equipment off when not in use. Do not blow compressed air through the meter. Prevent liquids from drying
inside the meter.Do not alter or modify the product. Alterations or modications to the product may invalidate the
approvals and cause safety hazards. Place the pipes and cables away from trafc, sharp edges, moving parts, and
hot surfaces. Do not twist or bend the hoses too much, do not move the product by the hoses. Keep children and
animals away from the work area. Observe all of the safety regulations in force.
ALWAYS KEEP A WORKING FIRE EXTINGUISHER IN THE WORK AREA.
CAUTION: Flammable liquids. Observe the precautions against the risk of re or explosion.
Read the safety data sheets to know the specic hazards of the uids used. If there are ammable
liquids in the work area (petrol, glass cleaning liquids, etc.), you must be aware that the vapours
produced can ignite and explode. Only use the product in well-ventilated areas to prevent res and
explosions. Do not connect or disconnect the power cables or turn the lights on and o in the
presence of ammable vapours.
CAUTION: Dangerous liquids. Read the safety data sheets to know the specic hazards of the
uids used. When pouring dangerous liquids, always follow the safety measures provided by the
liquid manufacturer. Keep dangerous liquids in approved containers and dispose of them in
compliance with the applicable guidelines.
2.2 - First Aid
In the event of contact with EYES, SKIN, INHALATION or INGESTION, read the SAFETY DATA SHEET
of the uid used.
2.3 - Technical specications
Protective equipment characteristics: Wear equipment that is appropriate for the operations to be carried
out; Wear equipment that is resistant to the products used. Personal Protective Equipment to be worn:
Safety footwear Protective clothing Protective gloves Safety goggles

EN
2.4 - Packaging
The meter is supplied in a box bearing a label with the following data:
• Product • Flow direction of the uid (Up, Down, Right, Left)
• Product version • Gross weight
2.5 - Contents
QTY COMPONENT
1 TECH-FLOW, MAT-FLOW, R-FLOW
1 USE AND MAINTENANCE MANUAL
3 - OPERATING CONDITIONS
3.1 Environmental conditions
Temperature: min. -10°C / max. +60°C (*) Relative humidity: max. 90%
(*) Caution! The temperature limits shown refer to the components making up the meter and
should be respected to prevent any damages or malfunctions from occurring.
3.2 - Allowed uids forbidden uids
Allowed DIESEL FUEL with 2 to 5.5 cSt viscosity (at 38°C)
Minimum ash point (MF): 55 °C
LIGHT OIL with 10 to 200 cSt viscosity (at 40°C)
Forbidden petrol, ammable liquids (mf <55°c), food liquids, solvents, liquids with > 200 cst
viscosity, water, corrosive chemicals
A
D
B
S
3.3 - Meter orientation
For proper use, install the TECH-FLOW, MAT-FLOW or R-FLOW meter as
instructed on the back (uid direction arrow).
The meters can have uid outlet upwards, downwards, to the left or to the right.
4 - GENERAL INDICATIONS
4.1 - General Information
TECH-FLOW, MAT-FLOW, R-FLOW meters have 1” BSP-G threaded inlets and outlets that are anged
on both sides. The meter is designed for xed installation on a line.
I M P O RTA NT: Do not use conical connections that can damage the meter. When installing position a suction filter of at least 40 mesh.
4.2 - Mechanical meters
TECH-FLOW, MAT-FLOW, R-FLOW mechanical meters can have a 3-digit or 4-digit numerator, depending on
the version chosen. The meter is delivered pre-calibrated by the manufacturer and ready for installation.
IMPORTANT: Due to the dierent operating conditions, pre-calibration may be dierent than the
one required; it is therefore recommended to calibrate the meter with each installation (see CHAP. 5).
5 - CALIBRATION
5.1 - Fluid
Fluid litres = Fluid weighed ÷ Fluid density
Flow rate (in litres per minute, LPM) = Fluid litres ÷ Fluid dispensing time (in seconds) · 60

EN
1818
1616
1414
1212
16 18,516 18,5
5.2 - Calibration Procedure
Calibration procedure for mechanical TECH-FLOW,MAT-FLOW, R-FLOW meters:
Fill the container up to a measured quantity.
If the amount displayed does not match the measured quantity, the meter must be calibrated. Make sure
the pump is off and the system is not under pressure before moving onto the next point.
Remove the sealing plug and turn the calibration screw anticlockwise to
reduce the quantity displayed or clockwise to increase it (a full turn
changes the quantity displayed by about 2 litres).
Put the sealing plug back.
Repeat the previous points until calibration is acceptable.
CAUTION: if the amount of liquid dispensed is less than 5 litres, the device will not allow
calibration.
PROBLEMS: POSSIBLE CAUSES: SOLUTIONS:
The meter does
not read
Suction lter clogged Clean the lter
Meter placed incorrectly Check the direction arrow of the liquid on the body; if the meter has been installed
upside down it won’t work
Incorrect reading
precision
Flow rate too low or too high check the technical specications for the ow rate limits (Chap. 12.2)
Incorrect calibration Follow the procedure for a new calibration (Chap. 6.2)
Air inside the system Check for any air intake leaks and make sure the pump does not draw in air
6 - TROUBLESHOOTING
7 - MAINTENANCE
7.1 - Cleaning
TECH-FLOW, MAT-FLOW, R-FLOW meters do not have a suction lter. It is advisable to add a suction
lter of at least 40 mesh to prevent any residues from interfering with the mechanical parts measuring the
uid. To clean the lter, see the instruction manual provided with the lter used.
If the meter is to be scrapped, its parts are to be given to companies specialised in disposing of and
recycling industrial waste, as shown on the table below:
9 - DEMOLITION AND DISPOSAL
9.1 - Disposal Instructions
PARTS TO BE DISPOSED OF DISPOSAL METHOD
PACKAGING The packaging consists of biodegradable cardboard which can be sent to companies for normal pulp recycling.
METAL PARTS The metal parts, whether painted or aluminium and stainless steel, are usually recycled by companies specialised in the scrap
metal industry.
PARTS OF A DIFFERENT NATURE Other parts of the system in which the meter is installed, such as pipes, rubber gaskets, plastic parts and wiring, are to be given to
companies specialised in disposing of industrial waste.
APPLICABLE REGULATIONS
FOR CUSTOMERS IN THE
EUROPEAN UNION
The European Directive 2002/96/EC states that the equipment bearing this symbol on the product and/or on the packaging is
not to be disposed of with unsorted municipal waste. The symbol indicates that this product must not be disposed of with
normal household waste. It is the responsibility of the owner to dispose of these products and the other electrical and
electronic equipment through specific collection facilities appointed by the government or by local authorities.

The warranty provided by the manufacturer Adam Pumps Spa covers the product for 2 years from the date of production.
Adam Pumps Spa (manufacturer) provides its customers with:
a warranty that covers problems resulting from production and conformity defects in the purchased products
the warranty period starts from the date indicated on the CE label which indicates the date of manufacture. A label indicating the date of manufacture will be applied to those
products which are not provided with a CE label. Therefore, the warranty period will start from that date;
the warranty will become immediately null and void should the data of manufacture be illegible, for any reason, unless Adam Pumps Spa is responsible for this;
the warranty covers repairs or replacement of the product, in the event it cannot be repaired
repair operations can be carried out only by Adam Pumps or by Adam Pumps’ authorised centres;
the warranty will not be valid in the event the product is tampered with by unauthorised persons, bodies, and/or companies;
any warranty request is subject to approval by Adam Pumps. The goods can be returned only if provided with an authorisation code. Upon request, Adam Pumps will provide
this code which will invoke the warranty for the product to be repaired or replaced
unless otherwise agreed with Adam Pumps, the returned goods must be sent via transport pre-paid by who has invoked the warranty to Adam Pumps Spa;
goods returned without authorisation and/or with transport not paid can be rejected;
The warranty will not be applied in the following cases:
Failure to use or install the product according to Adam Pumps' instructions
The product has been used with unauthorised fluids.
The product has been modified or tampered with
The product is used in an area with power supply defects (voltage changes, current phase shift, etc.)
The product is used without the supplied suction filter (inside or outside the pump).
Immediately excluded from the warranty are: adhesive labels, plastic and metal casing, keyboards and masks, components subject to wear such as blades, impellers,
graphite brushes (where present in the motors), seals and gaskets in general.
10 - WARRANTY
EN
The Manufacturer is always available for any information required on installation, operation or maintenance of the machine. The
Customer should ask the questions clearly, with reference made to this Manual and to the instructions listed. Always remember
to specify the type of product.
11 - TECHNICAL SUPPORT
Technical Specications
SPECIFICATIONS TECH FLOW 3C
MAT FLOW 3C
TECH FLOW 4C
MAT FLOW 4C R-FLOW 3C R-FLOW 4C
Measuring system: Swinging plate Swinging plate Swinging plate Swinging plate
Degree of protection: IP55 IP55 IP55 IP55
Partial [digits]: 3 4 3 4
Totaliser [digits]: 6 8 6 8
Unit of measurement: litres, gallons* litres, gallons* litres, gallons* litres, gallons*
Min flow rate [l/min / GPM]: 20 / 5,28 20 / 5,28 20 / 5,28 20 / 5,28
Max flow rate [l/min/ GPM]: 120 / 31,7 120 / 31,7 120 / 31,7 120 / 31,7
Max pressure [bar/psi]: 3,5/50 3,5/50 10/145 10/145
Burst pressure [bar/psi]: 25/362 25/362 30/435 30/435
Precision [%]: ± 1 ± 1 ± 1 ± 1
Repeatability [%]: 0,2 0,2 0,2 0,2
Input/Output [BSP/G]: 1" F, Flanged 1" F, Flanged 1" F, Flanged 1" F, Flanged
Body material: Aluminium Aluminium Aluminium Aluminium
Swinging plate material: POM-C POM-C PBT PBT
O-Ring material: NBR NBR NBR NBR
Other materials in contact with the fluid: Brass, PPS, Steel Brass, Steel
Min/max operating temperature [°C]: -10 / +60 -10 / +60 -10 / +60 -10 / +60
Allowed fluids: Diesel, Light oil Diesel
Forbidden fluids: Gas, Alcohol, Petrol, Water
Noise [dBA]: < 75 < 75 < 75 < 75
Net weight [Kg]: 1,9 1,9 1,9 1,9
Single size packaging [mm]: l 220 x b 150 x h 220
Gross weight [Kg]: 2,2 2,2 2,2 2,2

EXPLODED VIEWS
4C DESCRIPTION QTY
5MA998 FACEPLATE 1
6TF045 MECHANICAL NUMERATOR 1
TECH FLOW 3C-4C
27 20 21 11 12 13 15 16 14 10 17 19
23
242526 422 318 1986
28
25
7
BOM-TF3A1-exp
N. Articolo
Denominazione
Codice Materiale Q.TA'
1
CUFFIA INFERIORE T.FLOW VERNIC.
NERO TF014N
ABS grigio
1
2
CUFFIA SUPERIORE T.FLOW VERNIC.
NERO TF013N
ABS grigio
1
3
Lato cuffia con foro
TF015
ABS nero
2
4
Tappo plastica lamellare azzeramento
60302000
Nylon
1
5
Mascherina 3C Adamp Pumps
MA013
Poliestere EBG 180
1
6
TESTATA NUMERATORE 3C/4C
-
Materiale <non
specificato>
1
7
POMELLO RESET CAVA TONDA -
UNIVERSALE
TF012X
ABS nero
1
8
INGRANAGGIO CONICO
TF005
POM generico
1
9
Corpo Contalitri Tech Flow
TF011
Al 46100
1
10
Semicamera Inferiore T.Flow
TF002
POM generico
1
11
Semicamera Superiore T.Flow
TF003
POM generico
1
12
Disco oscillante T.Flow
TF001
POM generico
1
13
O-Ring Ø24 x 2 NBR
OR001
NBR 70 Shore A (Nero)
1
14
Vite di calibrazione T.Flow
TF019
Ottone
1
15
Tappo calibrazione 1/8" T.Flow
TF018
Acciaio Inox
1
16
O-Ring 108 NBR
11010100200
NBR 70 Shore A (Nero)
1
17
O-Ring 2018 NBR
11010050200
NBR 70 Shore A (Nero)
1
18
Flangia contalitri 3C
TF010
EN AC-AlSi11Cu2 (ex. EN
AB 46100)
1
19
O-Ring 4500 NBR
OR002
NBR 70 Shore A (Nero)
1
20
Piastrino supp. ingranaggi T.Flow
TF009
PPS + 40% FV
1
21
Perno con levetta T.Flow
TF008
POM generico
1
22
Ingranaggio cilindrico T.Flow
TF004
POM generico
1
23
Spina cementata diam. 2x17.8
6051800000
(*)
1
24
Ruota dentata doppia d36 T.Flow
TF006
POM Copolimero
acetalico
1
25
Ruota dentata d45 T.Flow
TF007
POM generico
1
26
O-Ring 2015 NBR
11010040200
NBR 70 Shore A
1
27
Vite TCCE M6x20 Trilobata DIN 7500 E
VT001
Classe 8.8
4
28
Vite TC Croce M4x10 Trilobata UNI 8112
80901439100
Classe 8.8
2
4321
A
B
C
D
E
F
8765 1211109
G
H
A
B
C
D
E
F
G
H
1211109
8765
4321
Proprietà della ADAM PUMPS Spa - Senza autorizzazione scritta della stessa il presente disegno non potrà essere comunque utilizzato per la
costruzione dell' oggetto rappresentato, nè venire comunicato a terzi o riprodotto. La società proprietaria tutela i propri diritti a rigore di legge.
Formato
A2
Codice
Denominazione
Contalitri tech flow 3C ADAM (A)
1:20
Scala
-
Materiale
Revisioni
Rev.
RM n°
Data
Firma
D. Stassi
Disegnato
30.03.2012
1
-
-
-
Data
Tolleranze generali
UNI EN 22768-mK
3.7835 kg
Peso indicativo
30.03.2012
Data
Approvato
1 di 1
Foglio
2
-
-
- -
-
3
- -
-
4
-
6
-
8
-
- -
-
--
-
5
-
7
-
-
-
-
-
-
9
TF3A1
Proprietà
- Componente Adam Pumps -
3C DESCRIPTION Q.TY
1 TF014N BOTTOM COVER 1
2 TF013N TOP COVER 1
3 TF015G SIDE COVER WITH HOLE 2
4 60302000 PLASTIC CAP 1
5 MA999 FACEPLATE 1
6 TF044 MECHANICAL NUMERATOR 1
7 TF012X RESET KNOB 1
8 TF005 CONICAL GEAR 1
9 TF011 METER BODY 1
10 TF002 BOTTOM HALF-CHAMBER 1
11 TF003 TOP HALF-CHAMBER 1
12 TF001 SWINGING PLATE 1
13 OR001 O-RING Ø24 X 2 1
14 TF019 CALIBRATION SCREW 1/8" 1
3C DESCRIPTION Q.TY
15 TF018 CALIBRATION CAP 1/8" 1
16 11010100200 O-RING 108 NBR 1
17 11010050200 O-RING 2018 NBR 1
18 TF010 METER FLANGE 1
19 OR002 O-RING 4500 1
20 TF009 GEAR SUPPORT 1
21 TF008 PIN WITH LEVER 1
22 TF004 CYLINDRICAL GEAR 1
23 6051800000 ROLLER Ø2 1
24 TF006 DOUBLE GEAR WHEEL Ø36 1
25 TF007 GEAR WHEEL Ø45 1
26 11010040200 O-RING 2015 NBR 1
27 VT001 SCREW M6X20 4
28 80901439100 SCREW M4X10 2

MAT FLOW 3C - 4C
3C 4C DESCRIPTION QTY
1PHANTOM3 PHANTOM4 3/4DIGIT MAT FLOW 1
2TF063 TF063 RESET KNOB 1
360302000 60302000 RESET CAP 1
4TF044 TF045 NUMERATOR HEAD 1
5TF069 TF069 MAT-FLOW COVER 1
6OR040 OR040 O-RING 130x3 NBR 70 1
7MA984 MA983 FACEPLATE 1
8MA071 MA071 “MADE IN ITALY” LABEL 1
913101006 13101006 SCREW M3x10 ISO7046 2
10 TF005 TF005 CONICAL GEAR 1
Adam Pumps S.p.A.
Soc. con Socio Unico
via della resistenza 46/48 - 41011 Campogalliano (MO) ITALIA
MADE IN ITALYMADE IN ITALY
mechanical meter diesel
category model
6
103 47
8
2
9 5 1
3C 4C DESCRIPTION QTY
1 PHANTOM3 PHANTOM4 3/4DIGIT MAT FLOW 1
2 TF063 TF063 RESET KNOB 1
3 60302000 60302000 RESET CAP 1
4 TF044 TF045 NUMERATOR HEAD 1
5 TF069 TF069 MAT-FLOW COVER 1
6 OR040 OR040 O-RING 130x3 NBR 70 1
7 MA984 MA983 FACEPLATE 1
8 MA071 MA071 “MADE IN ITALY” LABEL 1
9 13101006 13101006 SCREW M3x10 ISO7046 2
10 TF005 TF005 CONICAL GEAR 1
MAT FLOW 3C - 4C

R-FLOW 3C - 4C
2
12
10 7 8 5
18
14 3
21
22
15
19204
6
9
11
1
24
1326172523
16
27
28
N°
CODE
Description
Q.ty
1
OR051
QUAD-RING (3,68x1,78) FKM 70SH
1
2
TF095
CHAMBER LID
1
3
TF097
METER BODY
1
4
TF098
GEAR HOLDER
1
5
TF099
GEAR WHEEL SHAFT Z.14
1
6
TF100
GEAR WHEEL Z14
1
7
TF101
WHEEL GEAR SHAFT Z .61/11 Z.61/23
1
8
TF102
SHAFT BUSHING Ø3MM
1
9
TF103
GEAR WHEEL Z61-Z11
1
10
TF104
GEAR WHEEL Z62
1
11
TF105
CONIC PINION SHAFT
1
12
TF106
BUSHING CONIC SHAFT
1
13
TF107
CONIC PINION Z14
1
14
TF108
DRAG LEVER
1
15
TF110
BYPASS CLOSING CAP WITH O-RING
1
16
TF111
HOLED COVER CAP
1
17
TF112
CAP COVER
1
18
VT048
SCREW TC 3,5X12 UNI8112 AUTOFORMING
2
19
OR045
O-RING 4450 (113,89x3,53) NBR 70SH
1
20
TF096
MEASURE CHAMBER
1
21
TF109
ADJUSTMENT BY-PASS SCREW WITH O-RING
1
22 11010100200
O-Ring 108 NBR
1
23
VT071
SCREW TC M4x20 8.8 UNI8112
6
24
VT040
SCREW TC CROSS M5x16 SELF FORMING UNI8112
8
25
TF091
METER COVER
1
26
TF045
4C DIGITS HEAD LITERS
1
27
TF063
MAT FLOW RESET KNOB
1
28
MA147
4C LABEL
1
R-FLOW
4C DESCRIPTION Q.TY
1 OR051 QUAD-RING (3,68x1,78) FKM 70SH 1
2 TF095 CHAMBER LID 1
3 TF097 METER BODY 1
4 TF098 GEAR HOLDER 1
5 TF099 GEAR WHEEL SHAFT Z.14 1
6 TF100 GEAR WHEEL Z14 1
7 TF101 WHEEL GEAR SHAFT Z .61/11 Z.61/23 1
8 TF102 SHAFT BUSHING Ø3MM 1
9 TF103 GEAR WHEEL Z61-Z11 1
10 TF104 GEAR WHEEL Z62 1
11 TF105 CONIC PINION SHAFT 1
12 TF106 BUSHING CONIC SHAFT 1
13 TF107 CONIC PINION Z14 1
14 TF108 DRAG LEVER 1
4C DESCRIPTION Q.TY
15 TF110 BYPASS CLOSING CAP + O-RING 1
16 TF111 HOLED COVER CAP 1
17 TF112 CAP COVER 1
18 VT048 SCREW TC 3,5X12 UNI8112 2
19 OR045 O-Ring 4500 NBR 1
20 TF096 MEASURE CHAMBER 1
21 TF109 ADJUSTMENT BY-PASS SCREW +O-RING 1
22 11010100200 O-Ring 108 NBR 1
23 VT071 SCREW TC M4x20 8.8 UNI8112 6
24 VT040 SCREW TC CROSS M5x16 8
25 TF091 METER COVER 1
26 TF045 4C DIGITS HEAD LITERS 1
27 TF063 MAT FLOW RESET KNOB 1
28 MA147 4C LABEL 1
3C DESCRIPTION Q.TY
26 TF044 3C DIGITS HEAD LITERS 1
28 MA146 3C LABEL 1

TECH FLOW
200
1" BSP-G
1" BSP-G
102
129
191
Proprietà della ADAM PUMPS Spa - Senza autorizzazione scritta della stessa il presente disegno non potrà essere comunque utilizzato per la
costruzione dell' oggetto rappresentato, nè venire comunicato a terzi o riprodotto. La società proprietaria tutela i propri diritti a rigore di legge.
Codice
Denominazione
CONTALITRI TECH FLOW 3C ADAM (S)
TF3S1
OVERALL DIMENSIONS
176
186
1" BSP-G
1" BSP-G
106
134
155
Proprietà della ADAM PUMPS Spa - Senza autorizzazione scritta della stessa il presente disegno non potrà essere comunque utilizzato per la
costruzione dell' oggetto rappresentato, nè venire comunicato a terzi o riprodotto. La società proprietaria tutela i propri diritti a rigore di legge.
Codice
Denominazione
Mat-Flow meter
MATFLOW
R-FLOW
MAT FLOW
MADE IN ITALY
Adam Pumps S.p.A.
Soc. con Socio Unico
via della resistenza 46/48 - 41011 Campogalliano (MO) ITALIA
tutte le dimensioni espresse in mm - all dimensions are in mm
ingombri - overall dimensions
documento - document prodotto - product
196
INLET 1" BSP-G
OUTLET 1" BSP-G
134
157
107
Proprietà della ADAM PUMPS Spa - Senza autorizzazione scritta della stessa il presente disegno non potrà essere comunque utilizzato per la
costruzione dell' oggetto rappresentato, nè venire comunicato a terzi o riprodotto. La società proprietaria tutela i propri diritti a rigore di legge.
Codice
Denominazione
CONTALITRI MAT FLOW 3 C ADAM (S)
MF3S1
MAT FLOW
4C
3C
This manual suits for next models
5
Table of contents
Popular Water Pump manuals by other brands

Grundfos
Grundfos MAGNA3 25-100 (N) manual

BOMBAS IDEAL
BOMBAS IDEAL APM Series Use and maintenance instructions

Homa
Homa Saniquick II-UF Series Installation and operation instruction manual

Reefe
Reefe DRS Series Instruction manual & warranty

Toolland
Toolland TM76075N user manual

Agilent Technologies
Agilent Technologies R1330-529 HS-16 Instruction manual supplement

pumpa
pumpa BLUE LINE PSXA Translation of the original instruction manual

JABSCO
JABSCO 30520-0001 manual

Allfett
Allfett Multi Line ALL-25 Series INTRODUCTION AND USER MANUAL

Peerless Pump
Peerless Pump PE-B Series instructions

Craftsman
Craftsman 390.304692 owner's manual

nomad
nomad NTG40 TRANS-FLO Operation manual