Good Times 8451294 Administrator Guide


OUR VISION...
Everyone should have the opportunity to enjoy our little piece of the ‘Aussie Dream’.
Designed and manufactured to the Building Code and suitable for domestic and
commercial use less than 1 metre high. Build your own “Goodtimes” in a configuration
that meets your needs.
All you require is:
What surface can you build a Good Times deck on?
A Good Times DIY modular deck can be built on concrete (ie alfresco areas), existing
pavers or even on grass/soil (using a concrete paver as your support base).
Introduction
The Goodtimes DIY Modular Decking System is a fast and cost eective way to build
your own deck. It consists of modular base frames that sit on a variety of dierent
adjustable supports that enable retrofitting into any existing area without digging any
holes. Prefabricated decking panels make laying your deck fast and easy.
Various Drill Bits:
3mm Drill Bit
47mm 3/8” Nutsetter
64mm 1/4” Nutsetter
47mm x 5mm Hex Drive
64mm Phillips Head Drive #2
4mm Drill Bit
Impact Driver, Electric
or Cordless Drill
Shifter or Spanner
to suit 16mm nut
Tape Measure
Drop Saw
Should you wish to
cut your own decking
and baseboards
Various Drill Bits
(Refer to list)
Spirit Level
1

Step 1: Choose the size of your decking
• Measure the height of your deck
• Measure the size of your deck
• To help plan and cost your deck, login
to our website and use the deck planner
Step 2: Assemble your Base Frames
• Base Frames are available in 70x45mm
and 90x45mm (for Domestic use only)
or 140x35mm (for Domestic, Commercial
and Steps).
• Select a number of base frame kits.
• Using an electric or cordless drill, predrill
(4mm hole) and assemble the base frame
members using the screws purchased
(fixings not included). Note: Outside
frames are pre-drilled but end grain is not.
• Refer to the “Select your Fixings” table
below for required fixings as they are not
included with the base frame kit.
Pre-Drill
Use this chart to find the right screws to
build your Good Times Co. Modular Deck
Base Frame Kits
Merbau/Pine Half Deck
Panel to Base Frame
Ekodeck+ Panel
to Base Frame
Dropper Part ‘A’
to Base Frame
Step Connector
to Base Frame
Dropper Part ‘A’ to
Dropper Part ‘B’
Base Frame to
Base Frame
Steele Support to
Base Frame (1 frame)
Steele Support to
Base Frame (2 frames)
Vertical Cladding to
Dropper Part ‘B’
TYPE OF SCREW AND SIZE
External Timber Screws. Galvanised
(Countersunk Rib, Phillips Head) 10ga - 8 x 65mm 12 Min 2
Quickfix Hidden Fastening System
Stainless steel & Plastic components
Standard Clips 5-7
Locking Clips 2
Timber Screw. Galvanised, Type 17
(Bugle Head Batten) 14ga - 10 x 75mm 16
Timber Screw Galvanised,
Type 17 (Hex Head)
14ga -10 x 90mm
(90mm Base Frame
to Base Frame)
6
14ga -10 x 65mm
(140mm Base Frame
to Base Frame)
2 4 Min 2 6 4
Timber Screw Galvanised,
Type 17 (Hex Head, Full Thread) 12ga - 11 x 30mm 4
Select Your Fixings FIXINGS PER CONNECTION ITEM
2

Step 3: Set your heights and join Base Frames
CONNECTING SUPPORTS TO FRAMES:
• Lower height ranges using only the 50mm or 100mm foot have a knock in tube end
which goes directly into the base frame’s pre-drilled holes. Unscrew the tube end,
then using a hammer, knock it into the underside of the base frame module ensuring
only one is inserted at an intersection (see page 4). Once this is done, reattach the
foot – you can use the key head at the top of the foot to adjust the height by using
a cordless drill through the hole in the top of the frame.
• All other height ranges require a 2 piece support, including a steel component and
150mm foot. Screw the 150mm foot into the base of the steel support. Place the top
of the steel support into the internal corner of the base frame module and attach using
the fixings purchased (see Step 2 – Select your fixings), remember to pre-drill a shallow
4mm hole in the timber. Ensure only one support is attached at an intersection.
SELECT YOUR SUPPORT
COMPONENTS FROM
THE FOLLOWING TABLES
Steel Support Support Feet
Base Frame Kit - 70x45mm (Domestic)
Height Range Steel Support Support Feet
110mm - 150mm NO 50mm
Note: Lock nut to be removed from adjustable foot to achieve the minimum heights above
Base Frame Kit - 140x35mm (Domestic and Commercial)
Height Range Steel Support Support Feet
180mm - 260mm NO 100mm
250mm - 415mm 140mm 150mm
380mm - 545mm 270mm 150mm
510mm - 675mm 400mm 150mm
640mm - 805mm 530mm 150mm
Note: Lock nut to be removed from adjustable foot to achieve the minimum heights above
Base Frame Kit - 90x45mm (Domestic)
Height Range Steel Support Support Feet
130mm - 220mm NO 100mm
200mm - 365mm 140mm 150mm
330mm - 495mm 270mm 150mm
460mm - 625mm 400mm 150mm
590mm - 755mm 530mm 150mm
Note: Lock nut to be removed from adjustable foot to achieve the minimum heights above
3

2 piece supports can
go in any of these
positions - use only
one per intersection.
Tube ends can only
go in these positions
(flange exposed).
Use only one
per intersection.
JOIN YOUR BASE FRAMES:
• Once supports are connected to the individual base frames, flip the frames over
and place in position.
• Align the top of the frames.
• Make frame to frame connections at below locations using screws purchased
(not included) remembering to pre-drill a 4mm hole first.
Make connections
in middle
100mm max
from edge
Tube end flange
exposed outside
timber
Tube end
inside timber
2 Piece
Support
The Support feet can sit directly on a solid surface
(such as concrete, bitumen or pavers). If installing
over grass or soil, use a concrete paver (approximately
300x300x40mm) as a base for the Support Foot.
4

Step 4: How to add Steps
Follow the below instructions to add steps
using more modules
1. SELECT YOUR TIMBER:
• Additional levels/steps are connected using STEP CONNECTORS which are to be
cut from 90x45mm treated pine.
• Ensure all steps assembled are the same height to comply with the Building Code
of Australia.
2. CUT STEP CONNECTORS TO SIZE
For a 140x35mm base frame kit
the step connector should be 270mm
in length.
The bottom of the connector should line
up flush with the bottom of the lower level
base frame. This ensures there is 30mm
clearance between the step connector
and upper level deck panel.
3. SECURE STEP CONNECTOR
Using 14ga -10x65mm Timber Screw
Galvanised, Type 17 (Hex Head) screws
secure connector to Base Frames as
per example.
Remember to pre-drill 4mm hole once
lined up but do not drill all the way
through. Ensure the holes are lined up
down the centre of the step connector.
Decking PanelsDecking Panels
270mm
30mm
Step
Connector
5

1. SELECT TIMBER FOR YOUR DROPPERS:
Purchase length/s of timber that match your base frame kit:
If your base frame is 90x45mm select a 90x45mm timber for component ‘B’ (See Fig.1). If
your base frame is 140x35mm select a 90x35mm timber for component ‘B’. Component ‘A’
should always be constructed from 90x45mm timber regardless of the base frame size.
Correct selection of material for component ‘B’ will ensure a flush surface for mounting
the vertical cladding.
2. CUT DROPPER COMPONENTS TO SIZE:
Your Dropper should be constructed in two parts, ‘A’ and ‘B’ (see Fig 1). Begin by calculating
component ‘A’s length. Component ‘A’s length should be calculated using this formula:
Deck height - 30mm clearance from top of the base frame - 50mm clearance from the
ground. E.g. using a deck height of 650mm; 650mm high deck - 30mm - 50mm = 570mm
(is length of component ‘A’).
Then construct component ‘B’:
For a 140x35mm base frame ‘B’ should be 110mm shorter than ‘A’
For a 90x45mm base frame ‘B’ should be 60mm shorter than ‘A’
3. ASSEMBLE AND ATTACH DROPPERS TO BASE FRAME:
Secure Component ‘A’ to ‘B’ using a staggered screw pattern. The two screws securing
the dropper to your base frame should be vertically aligned and not staggered (refer
to Fig 1.) Ensure staggered screws are no more than 150mm apart. Pre-drill 4mm holes
where required.
*Fix the corner dropper close to the corner of the base frame.
Step 5: Clad and install your Decking
Follow the below instructions to install your decking
and conceal the supports of your deck.
Fig 1. Fig 2.
Base Frame
Deck Panel
Vertical Cladding
Component ‘A’
Component ‘B’
Ground Level
50mm min
Base Frame
(Inside Frame)
Cladding
Cladding
A
B
6

4. SELECT YOUR DECKING MATERIALS (TWO OPTIONS):
• Purchase a random length pack of decking from Bunnings and cut in your own type
of decking.
- OR -
• Select the required number of prefabricated decking panels (1113x555mm) and fill
in your deck. They have been split into 2 halves so they fit into a car and can be lifted
by one person (20 kg max weight).
5. INSTALL PREFAB DECKING PANELS
• Drop the Decking Panels into position over the Base Frame. The decking boards should
run in the opposite way to the internal frame members.
• Take care to line up the gaps between the panels and fix into position with fixing screws.
TIP: Use Masonite packing strips to achieve perfect gaps
• Run panels the same way or in a parquetry pattern depending on how you assemble the
base frames.
6. ENCLOSE VERTICAL FACES
If you have decided to cut in your own deck or clad the vertical faces of your decking
you can contact your local Bunnings for advice on the best product for your project.
• 140x19mm Vertical cladding matches the 140x35mm base frames for height. 90x19mm
vertical cladding matches the 90x45mm base frames.
Care and Maintenance
Enjoy your new deck for years to come by:
• Not having the timber in contact with the ground.
• Using stainless steel fixing in sea side areas.
• Merbau panels should be stored in a dry, undercover
area. Merbau is tannin rich and leaching will occur
upon installation. It is recommended and can prolong
the life of your deck by applying a suitable oil or stain
to these panels (ensure it is clean before application).
Oiling the deck boards every year will keep your deck
looking like new.
Droppers should be positioned at maximum spacings of 600mm apart.
Use 14 - 10x65mm Type 17 Galvanised Hex Head Timber screws to connect
component ‘A’ to base frame and component ‘A’ to component ‘B’. Use 10ga - 8 x 65mm
Galvanised Counter Sunk Ribbed with Phillips Head screws to connect vertical cladding to
component ‘B’.
7
*Refer to pages 8 and 9 for Screw/Fixing positions for both Standard and Parquetry layouts.

555mm 555mm 555mm555mm
1113mm 1113mm
1113mm
555mm 555mm
1113mm
1113mm
555mm 555mm
1113mm
Standard Layout: Pine/Merbau Panels
Parquetry Layout: Pine/Merbau Panels
Joists
Decking Panel
Perimeter
Standard Screw
Fixing locations
Joists
Decking Panel
Perimeter
Standard Screw
Fixing locations
8

555mm 555mm 555mm555mm
1113mm 1113mm
1113mm
555mm 555mm
1113mm
1113mm
555mm 555mm
1113mm
Standard Layout: Ekodeck+ Panels
Parquetry Layout: Ekodeck+ Panels
Joists
Decking Panel
Perimeter
Lock-in Clip and
Screw locations
Standard Clip and
Screw locations
Joists
Decking Panel
Perimeter
Lock-in Clip and
Screw locations
Standard Clip and
Screw locations
9