Systems Tested and Certied to NSF/ANSI 58
Good Water Warehouse Reverse Osmosis System
NSF 58
Part Number: GOLDLINE-50
GWW Inc.
1700 E Walnut Ave
Fullerton CA 92831
(714) 441-2893
(714) 441-0525 FAX
Good Water Warehouse Inc.
1. Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
Systems certied for cyst reduction may be used on disinfected water that may contain lterable cysts.
2. No iron present in feed water to R.O. System
4. Hardness of more than 7 grains may shorten membrane life
5. Manufacturer recommends a TDS test every six months
6. Efciency rating means the percentage of the inuent water to the system that is available to the user as reverse osmosis treated water
under operating conditions that approximate typical daily usage.
7. Recovery rating means the percentage of the inuent water to the membrane portion of the system that is available to the user as reverse
osmosis treated water when the system is operated without a storage tank or when the storage tank is by passed.
8. This system is acceptable for treatment of inuent concentrations of no more that 27 mg/L nitrate and 3 mg/L nitrite in combination
measured as N and is certied for nitrate/nitrite reduction only for water supplies with a pressure of 40 psi or greater.
9. The Goldine-50 installation should comply with all state and local laws and regulations.
10. This Reverse Osmosis System contains a replaceable treatment component critical for effective reduction of total dissolved solids. The
product water shall be tested periodically to verify that the system is performing satisfactorily.
11. See owners manual for manufacturer's limited warranty, installation, operation and maintenance requirements.
12. This system has been tested and shown to operate at its calculated recovery rating, or efciency rating, or both under standard test
conditions. Test parameters: 25º± 1ºC, 50 psi and pH of 7.5.
13. Chlorine in the inuent water may affect the RO membrane polymers.
General installation / Operation / Maintenance Requirements
Recommended Replacement of Membrane and Filters
R.O. Membrane 1204694 2 to 5 years
Sediment Prelter 1227867-V 6 months
Carbon Block Prelter 32-250-125-975 6 months
Carbon Block Prelter 32-250-125-975 6 months
Post Carbon Filter CL10ROT40-B 6 months
Contaminant
Ave.
Inuent
(mg/L)
Ave.
Efuent
(mg/L)
Ave. %
Reduction
US EPA
MCL
(mg/L)
* Barium 9.4 0.58 93.8 0.84
Cadmium 0.03 0.0004 98.7 0.0006
Chromium
(Hexavalent)
0.29 0.026 91.2 0.033
Chromium
(Trivalent)
0.32 0.017 94.8 0.022
Copper 3.0 0.033 98.9 0.066
Fluoride 8.6 0.4 95.6 0.5
Lead 0.15 0.002 98.7 0.003
Radium
226/228
25 pCi/L 5 pCi/L 80.0 5 pCi/L
Selenium 0.099 0.004 96.0 0.004
Turbidity 11 NTU 0.1 NTU 99.0 0.2 NTU
TDS 739 45 93.8 82
This system has been tested according to NSF/ANSI 58 for reduction of substances listed below. The concentration of the indicated substances in water
entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specied in NSF/ANSI 58.
Testing was performed under standard laboratory conditions, actual performance may vary.
Daily Production Rate 11.19 gpd
Recovery rate 23.87 %
Pressure Drop at Rated Flow 5 psi
System Weight 30 lbs
Efciency Rating 8.67 %
Min. / Max. Pressure 30/100 psi
Min. / Max. Temperature 4º/38ºc (40º/100º F)
Production Storage Capacity 2.4 gallons
A performance indicator will monitor the performance of the RO membrane,
a critical component for the reduction of the above contaminants
Test parameters: 25º± 1ºC, 50 psi and pH of 7.5
Refer to owners manual for additional maintenance and warranty information
WQA certied for the reduction of:
TDS, Barium, Cadmium, Hexavalent and Trivalent Chromium, Lead,
Radium 226/228, Selenium, Fluoride, Nitrite, Nitrate