Gorgy Timing RS232 User manual

MDE-AFFICHEUR-LEDI-GRAPH-5030V1.0
1
LEDI GRAPH
OUTDOOR TEXT LED DISPLAY
INDOOR TEXT LED DISPLAY
GORGY DISPLAY
USER MANUAL

2
MDE-AFFICHEUR-LEDI-GRAPH-5030V1.0
WARNING! The following section provides the safety instructions for installation.
Please read it carefully before installing your device.
To protect your device, plug it into a grounded outlet.
The device must be connected to an electrical installation which is in accordance with
the NF C15-100 standard.
This appliance does not have a primary power switch: A quickly accessible
disconnecting device (circuit breaker or switch-disconnector) must be incorporated in
the wiring installation.
The device must withstand the rated voltage and current values indicated on the
device.
In Europe: in accordance with European regulations on the protection of individuals
and the environment, it is your responsibility to dispose of this equipment at a collection
site designed for this purpose (separately from household waste). For further
information, contact your reseller, your collection site or the relevant local authorities.
Any modification or opening of the product without the consent from the Customer
service department will void the warranty.
The LEDI®GRAPH must only be installed, maintained and handled by competent and
knowledgeable persons.
All maintenance operations must be carried out with the power off, including for
systems connected to any relay outputs.
As a general rule, to avoid any interferences, the power (230V supply) and signal (time
information) cables must not be too close to each other. (keep a few centimetresapart)
CAUTION! After unplugging the LEDI®GRAPH, there is a risk of electric shock from
the power connector/plug socket for up to 2 seconds.
To avoid the risk of electrical interference, position the LEDI® GRAPHas far as possible
from sources of radiation (Loudspeakers, antennas, high-frequency equipment,
electromagnetic alarms…).
Gorgy Timing disclaims all liability in the event of accident or damage caused by
improper use of LEDI® GRAPH.
All GORGY TIMING products comply with the following standards: CE, EN60950-1,
EN55022 class B, EN50024.
IMPORTANT SAFETY INSTRUCTIONS

MDE-AFFICHEUR-LEDI-GRAPH-5030V1.0
3
ENGLISH
General hazard –there is a risk of damage to the product if instructions are not followed
Electrical hazard –there is a risk of electrocution or personal injury if instructions are not
followed.
Equipment fully protected by double insulation.
Warnings
Please follow the precautions and instructions indicated below in order to ensure the safety of you and
your environment, and to prevent any potential damage to your device.
The LEDI® GRAPH is intended for indoor or outdoor use, at an altitude of less than 2000
metres.
Waste disposal by users in private households within the European Union
This symbol on the product or its packaging indicates the product must not be disposed of with
your general household waste. Instead, it is your responsibility to dispose of your waste by
taking it to a designated collectionpoint forthe recycling of electrical and electronic appliances.
The separate collection and recycling of your waste contributes to the conservation of natural
resources and helps to ensure that recycling is environmentally and health friendly. For more
information about your nearest recycling centre, pleasecontact the shop where you purchased
your device, the household waste disposal services or your local authorities.
EXPLANATION OF SAFETY SIGNS ON THE PRODUCT

4
MDE-AFFICHEUR-LEDI-GRAPH-5030V1.0
CONTENTS
CONTENTS..........................................................................................................................4
1. INTRODUCTION........................................................................................................6
1.1. FEATURES.................................................................................................................6
1.2. ELEMENT IDENTIFICATION......................................................................................7
1.3. OPERATION MODE...................................................................................................9
1.4. OUTDOOR LED DISPLAY........................................................................................10
1.4.1. Technical specifications ...................................................................................10
1.4.2. Dimensions......................................................................................................11
A. 16x160px Outdoor LED Display P8..................................................................11
B. 32x160px Outdoor LED Display P8..................................................................12
C. 64x160px Outdoor LED Display P8..................................................................12
D. 96x160px Outdoor LED Display P8..................................................................13
E. 16x160px Outdoor LED Display P10................................................................13
F. 32x160px Outdoor LED Display P10................................................................14
G. 64x160px Outdoor LED Display P10................................................................14
H. 96x160px Oudoor LED Display P10.................................................................15
1.5. INDOOR LED DISPLAY............................................................................................16
1.5.1. Technical specifications ...................................................................................16
1.5.2. Dimensions......................................................................................................17
A. 32x192px Indoor LED Display P4.....................................................................17
B. 64x192px Indoor LED Display P4.....................................................................18
C. 96x192 px Indoor LED Display P4....................................................................18
D. 32x160px Indoor LED Display P6.....................................................................19
E. 64x160px Indoor LED Display P6.....................................................................19
F. 96x160px Indoor LED Display P6.....................................................................20
1.6. PC SOFTWARE........................................................................................................20
1.6.1. Key features of “WZP Sign Software”...............................................................20
1.6.2. System requirement.........................................................................................21
1.6.3. Software operation...........................................................................................21
2. MECHANICAL INSTALLATION..............................................................................22
2.1. OVERVIEW.....................................................................................................................22
2.2. CABINET ASSEMBLE.....................................................................................................23
2.3. COMMON MOUNTING METHOD...................................................................................25
2.4. MOUNTING PROCESS...................................................................................................27

MDE-AFFICHEUR-LEDI-GRAPH-5030V1.0
5
ENGLISH
2.4.1. Hanging mounting method..................................................................................27
2.4.2. Wall mounting method..........................................................................................29
3.1. COMMON CONNECTOR AND CABLE...........................................................................37
3. ELECTRICAL CONNECTION .................................................................................37
3.2. CARD INFORMATION....................................................................................................39
3.2.1. Control card (WZPMAIN03-Fb) ............................................................................40
3.2.2. Multi-function card (CST-VS-MB-04g)..................................................................41
3.3. POWER CABLE CONNECTION......................................................................................42
3.3.1. External power cable connection..........................................................................43
3.3.2. Internal power cable connection...........................................................................43
3.4 DATA/SIGNAL CABLE CONNECTION.............................................................................47
3.4.1. Example for LED modules connection..................................................................47
3.4.2. RS422 Connection...............................................................................................48
3.5. FAN CONNECTION........................................................................................................50
3.6. SYSTEM CONNECTION.................................................................................................50
3.6.1. RS232 Communication ........................................................................................50
3.6.2. RS422 Communication ........................................................................................54
3.6.3. RS485 Communication ........................................................................................57
3.6.4. General modem communication...........................................................................57
3.6.5. GSM Modem Communication ..............................................................................60
3.6.6. RF modem communication...................................................................................62
3.6.7. TCP/IP network (LAN) communication.................................................................64
3.6.8. Optical modem communication ............................................................................65
3.6.9. GPRS modem communication .............................................................................67
4.1. MAINTENANCE OVERVIEW ..........................................................................................70
4. MAINTENANCE.......................................................................................................70
4.2. LED DISPLAY CABLE.....................................................................................................71
4.3. REPLACEMENT .............................................................................................................72
4.4. TROUBLESHOOTING.....................................................................................................73
4.5. Return and repair ............................................................................................................78
5. APPENDIX...............................................................................................................79
5.1. JUMPER FOR CARD................................................................................................79
5.2. SOME CABLE DEFINE.............................................................................................81
5.3. PC SOFTWARE LIST...............................................................................................81
5.4. FILE LOG .................................................................................................................82

6
MDE-AFFICHEUR-LEDI-GRAPH-5030V1.0
1. INTRODUCTION
This document is the instruction manual for the LEDI GRAPH. This product is designed for
larger size and low-cost LED sign. There are LED Display for indoor and outdoor use.
Communication standards is LAN (TCP/IP) and some optional communication modes are as
RS422 or NTP or GPS.
Powerful PC software to control LED Display sign is developed. It is “WZP Sign Software”
program and designed for Windows®computer. The current version does not support
infrared remote control programming.
1.1.FEATURES
Memory size
16 MB
Fonts
All fonts in Windows® system
Color
Seven kinds of basic colors such as red, green, yellow, white, blue, cyan,
purple, nineteen kinds of combined color and custom color.
OS
Real-time Multi-tasks Operating System LMOS. The screen can be
divided into several parts displaying individually.
Standard Interface
TCP/IP
Optional communication
method
RS422, NTP, GPS
Graphics
Bmp, Gif, Png
Animation
Gif animation
Symbol
All Unicode symbol in Windows®system
Date & Time format
User-defined
Temperature/Humidity/dew
Can display temperature, humidity and dew point. The temperature and
dew point unit is: Celsius, Fahrenheit or Kelvin, and the humidity unit is:
%.
Decounter
Count in days, hours, minutes, seconds.
Display methods
16 display methods. Auto, Immediate, Slide, Cover, Roll, Interlaced
Slide, Interlaced Roll, Shutter, Jump, Snow, Random, Shoot, Explode,
Twinkle, Flash, Pac man.
Message move speed
8 move speed from slowest speed 1 to fastest speed 8
Pause Time
0~60 seconds pause time, or stop permanently
Run in schedule
7 schedule modes. Run always, Run every year, Run every month, Run
every day, Run every hour, Run on given date and time, Run on given
time in given days.
System Upgrade
Easily upgrade through TCP/IP, RS422 interface

MDE-AFFICHEUR-LEDI-GRAPH-5030V1.0
7
ENGLISH
1.2.ELEMENT IDENTIFICATION
The following illustrations depict some of the more commonly accessed elements of LED
Display.
►LED Cluster Module
LED cluster module is an aggregation of some LED clusters/pixels and driver circuits. It may
be a card with LED clusters/pixels and driver circuits or included driver card and lamp card.
We call it as LED modules for expedience. It is a single functional unit that made up of a
whole display wall.
►Control card (WZPMAIN03-Fb)
Control card is a main board of LED sign. It is used for receiving data/signal from control PC
and transmitting it to multi-function card after processing.
►Multi-function card (CST-VS-MB-04g)
Multi-function card is used for receiving data from control card, then distributing data to LED
modules.

8
MDE-AFFICHEUR-LEDI-GRAPH-5030V1.0
►Light sensor
Used for automatic brightness adjustment. It includes interior light sensor. The interior light
sensor is installed inside of LED sign.
►Temperature sensor
Temperature sensor is used for getting temperature of environment or internal. It is needed
when display temperature on sign. It is an optional element for system. So in some system,
it may be no temperature sensor.

MDE-AFFICHEUR-LEDI-GRAPH-5030V1.0
9
ENGLISH
►Power Supply
It is AC/DC adapter. Convert AC line voltage from the load centre to low DC voltage, and
provides power for control cards and LED cluster modules. All the power supplies are
switching power supply.
1.3.OPERATION MODE
►The control PC should install “WZP sign Software” program.
►In general, LED Display adopts TCP/IP or RS422 mode to communicate with control
PC. And it needs the control PC to have at least a COM port or a Modem or other
devices between control PC and sign. The more information of each communication
mode will be described in latter content.
►The control card and multi-function card are installed in LED sign. The interior light
sensor needs is installed inside of LED sign without any cover.

10
MDE-AFFICHEUR-LEDI-GRAPH-5030V1.0
►Control card receives data/signal from control PC and transmits it to multi-function card
after processing. Then multi-function card distributes data/signal to LED modules after
processing.
►The LED sign system must be connected to earth-ground. Proper grounding is
necessary for reliable equipment operation and protects the system from damaging
electrical disturbances and lightning. Grounding resistance must be less than 10 ohm.
A proper grounding electrode must be pre-buried.
1.4.LEDI GRAPH OUTDOOR
1.4.1. Technical specifications
Table below lists down technical specifications of LEDI GRAPH Outdoor series.
Pixel pitch (mm)
8
10
Control system
ColoT (WZP) system (without grayscale)
Color Displayed
RGB
Module resolution
16x32 px
Led driver type
1/4duty
1/2duty
LED type
2 727 SMD 3 in 1, gold-wire led
Auto dimmer
Included
Continuous Working Time
Over One year
Average LED lifetime
100 000 hours
Brightness
5 500 cd/m2±10%
Viewing Angle
120°(Horizontal)/120°(Vertical)
Communication method
TCP/IP
Additional Communication mode
RS422, NTP, GPS, Dry contact
Communication distance
Max 1200m for RS422
Casing Material
Aluminum
Casing color
Matt light gray powder coated
Access of maintenance
Front access
IP level
Front IP65; Rear IP54
Working Temperature
-20°C to +50°C
Working Humidity
15% to 95% RH
Storage Temperature
-30°C to +60°C
Storage Humidity
10% to 90% RH
Power Input
230VAC, 50/60 Hz
Power supply
Meanwell power supply (CE approved)
Whole Sign Approval
Whole Sign with CE compliance; RoHS compliance;
Warranty
2 years

MDE-AFFICHEUR-LEDI-GRAPH-5030V1.0
11
ENGLISH
1.4.2. Dimensions
Table below lists down dimensions and power consumption of LEDI GRAPH Outdoor series.
Pixel
pitch
(mm)
Resolution
HxW
(pixels)
Screen
dimension
HxWxD (mm)
Net
weight
(Kg)
Gross
weight
(Kg)
Max. Power
consumption
Estimation
(W)
Average
power
consumption
Estimation
(W)
8
16x160
274x1 426x151
20
42
115
46
32x160
402x1 426x151
35
65
230
92
64x160
658x1 426x151
65
100
460
184
96x160
914x1 426x151
85
120
690
276
10
16x160
306x1 746x151
35
60
180
72
32x160
466x1 746x151
55
80
360
144
64x160
786x1 746x151
85
125
720
288
96x160
1106x1 746x151
120
160
1 080
432
A. 16x160px LEDI GRAPH Outdoor P8

12
MDE-AFFICHEUR-LEDI-GRAPH-5030V1.0
B. 32x160px LEDI GRAPH Outdoor P8
C. 64x160px LEDI GRAPH Outdoor P8

MDE-AFFICHEUR-LEDI-GRAPH-5030V1.0
13
ENGLISH
D. 96x160px LEDI GRAPH Outdoor P8
E. 16x160px LEDI GRAPH Outdoor P10

14
MDE-AFFICHEUR-LEDI-GRAPH-5030V1.0
F. 32x160px LEDI GRAPH Outdoor P10
G. 64x160px LEDI GRAPH Outdoor P10

MDE-AFFICHEUR-LEDI-GRAPH-5030V1.0
15
ENGLISH
H. 96x160px LEDI GRAPH Outdoor P10

16
MDE-AFFICHEUR-LEDI-GRAPH-5030V1.0
1.5.LEDI GRAPH INDOOR
1.5.1. Technical specifications
Table below lists down technical specifications of LEDI GRAPH Indoor series.
Pixel pitch (mm)
4
6
Control system
ColoT (WZP) system (without grayscale)
Color Displayed
RGB
Module resolution
32x64 px
32x32 px
Led driver type
1/20duty
1/16duty
LED type
2 020 SMD 3 in 1, gold-wire led
Auto dimmer
N/A
Continuous Working Time
Over One year
Average LED lifetime
100 000 hours
Brightness
600 cd/m2±10%
Viewing Angle
140°(Horizontal)/140°(Vertical)
Communication method
TCP/IP
Additional Communication mode
RS422, NTP, GPS, Dry contact
Communication distance
Max 1200m for RS422
Casing Material
Aluminum
Casing color
Black
Access of maintenance
Front
IP level
IP20
Working Temperature
-10°C to +40°C
Working Humidity
15% to 95% RH
Storage Temperature
-30°C to +60°C
Storage Humidity
10% to 90% RH
Power Input
230VAC, 50/60 Hz
Power supply
Meanwell power supply (CE approved)
Whole Sign Approval
Whole Sign with CE compliance; RoHS compliance;
Warranty
2 years

MDE-AFFICHEUR-LEDI-GRAPH-5030V1.0
17
ENGLISH
1.5.2. Dimensions
Table below lists down dimensions and power consumption of LEDI GRAPH Indoor series.
Pixel
pitch
(mm)
Resolution
HxW
(pixels)
Screen
dimension
HxWxD (mm)
Net
weight
(Kg)
Gross
weight
(Kg)
Max. Power
consumption
Estimation
(W)
Average
power
consumption
Estimation
(W)
4
32x192
159x809x61.5
6.5
8.5
33
13.2
64x192
287x809x61.5
12
14
66
26.4
96x192
415x809x61.5
17
19
99
39.6
6
32x160
223x1 001x61.5
11
13
65
26
64x160
415x1 001x61.5
20
22
130
52
96x160
607x1 001x61.5
30
32
195
78
A. 32x192px LEDI GRAPH Indoor P4

18
MDE-AFFICHEUR-LEDI-GRAPH-5030V1.0
B. 64x192px LEDI GRAPH Indoor P4
C. 96x192 px LEDI GRAPH Indoor P4

MDE-AFFICHEUR-LEDI-GRAPH-5030V1.0
19
ENGLISH
D. 32x160px LEDI GRAPH Indoor P6
E. 64x160px LEDI GRAPH Indoor P6

20
MDE-AFFICHEUR-LEDI-GRAPH-5030V1.0
F. 96x160px LEDI GRAPH Indoor P6
1.6.PC SOFTWARE
There is powerful PC software which named “WZP Sign Software” to manage LED Display.
It is designed for Windows®computer.
WZP Sign Software is a Windows application program designed for the LED Display. The
main function of WZP Sign Software is message editor/manager and control LED Display.
The running file of this software is “Wzpsoft.exe” which saved in “bin” folder. User maydouble
click the icon of Wzpsoft.exe to run this program.
It is allowed to control one and more LED Display simultaneously from a control centre
through network connection.
1.6.1. Key features of “WZP Sign Software”
►Edit text file
►Edit graphic (general image) file: *.bmp, *.png, *.gif
►Edit animation file: animation “*.gif” graphic
►Set date and time format
►Set temperature/humidity type
This manual suits for next models
2
Table of contents