GOVI arktik 1600N User manual

DE BETRIEBSANLEITUNG
The cooling diamond
1600N - 1600 N/T - 2000N - 2500N - 2000P - 2500 N/K - 2000 P/K
|EN |OPERATION MANUAL
Trailer Refrigeration Unit

OPERATION MANUAL - Trailer Refrigeration Unit
arktik 1600N • 1600 N/T • 2000N • 2500N • 2000P • 2500 N/K • 2000 P/K
50.04.504 / 1.0
Copyright by GOVI GmbH 2021. The reproduction of this document or any part thereof is prohibited. We reserve the right to make technical changes during the course of further developments.
2
Page
Please read this manual before you install and operate the trailer
refrigeration unit.
After reading the operating manual, keep it in a safe place for
future reference.

50.04.504 / 1.0
Copyright by GOVI GmbH 2021. The reproduction of this document or any part thereof is prohibited. We reserve the right to make technical changes during the course of further developments.
OPERATION MANUAL - Trailer Refrigeration Unit
arktik 1600N • 1600 N/T • 2000N • 2500N • 2000P • 2500 N/K • 2000 P/K
3
Page
1 General 4
1.1 Disposal of unit 4
2 Safety Instructions 5
2.1 Safety Messages and Safety Alert Symbols 5
2.2 Other Terms and Symbols 5
2.3 Safety and Hazard Precautions 6
2.4 Safety Precautions Concerning the Refrigerant 8
2.4.1 First Aid 8
2.4.2 Environmental Considerations 8
2.5 Intended Use 9
3 Technical Data 10
4 Package, Transportation and Storage 13
4.1 Package 13
4.2 Transport 14
4.3 Storage 14
5 System Description 15
6 Installation 17
6.1 Conditions for Installation 17
6.2 Additional Parts and Equipment 17
6.3 Preparatory Activities 18
6.3.1 General Preparation 18
6.3.2 Installation Opening of Trailer Wall 19
6.4 Installation of the Trailer Refrigeration Unit 19
6.5 Installation of Accessories 22
7 Operating Elements 23
8 Commissioning 24
9 Operating 26
9.1 Switchingon/otheTrailerRefrigerationUnit 27
9.2 Setting Nominal Temperature 27
9.3 Switchingon/otheLampintheRefrigeratedTrailer 27
9.4 Manual Defrost 27
10 Maintenance 28
10.1 Manual Defrost During Maintenance 28
10.2 Cleaning 28
10.2.1 Cleaning Parts Inside the Refrigeration Unit 28
10.2.2 Cleaning Parts Outside the Refrigeration Unit 29
11 Troubleshooting 30
12 Summary 31
13 Appendices 32
13.1 Operation Manual 32
13.2 Wiring Diagrams 33
13.3 Safety data sheets 40
13.4 Installation checklist 47
Contents

OPERATION MANUAL - Trailer Refrigeration Unit
arktik 1600N • 1600 N/T • 2000N • 2500N • 2000P • 2500 N/K • 2000 P/K
50.04.504 / 1.0
Copyright by GOVI GmbH 2021. The reproduction of this document or any part thereof is prohibited. We reserve the right to make technical changes during the course of further developments.
4
Page
GOVI provides this manual for information purposes only. Information
provided in this manual should at no time be regarded as all-inclusive or
covering all contingencies. For further information, please contact your
GOVI distributor.
Any change and alteration of this trailer refrigeration unit and deviation
from the installation process without prior written consent will void
GOVIʼswarranty.
Only use original spare parts or spare parts approved by GOVI. It is
explicitly pointed out that original spare parts and accessories which
are not supplied by GOVI are neither tested nor approved. GOVI cannot
assume any liability or warranty for damage caused by the use of non-
original spare parts.
The work on the trailer refrigeration unit described in this manual
may only be carried out by persons who, on the basis of the relevant
regulations and of their professional training, knowledge and experience,
can assess the work to be carried out and identify possible dangers.
GOVI is not responsible for personal injury or material damage which may
arisefromnon-approvedmodications.
In order to ensure the durability of GOVI products please follow the
instructions in this manual.
1.1 Disposal of the Unit
Danger of personal injuries and damage to the environment
due to improper disassembly of the trailer refrigeration unit.
Only qualied, trained specialists are allowed to disassemble
the trailer refrigeration unit. The refrigerant must be handled
with care as it poses serious health and environmental
hazards.
The customer is responsible for the proper disposal of the trailer
refrigeration unit.
Please follow local regulations regarding the disposal of the trailer
refrigeration unit and especially its refrigerant. If appropriate, consult
professionals or specialists.
1. General
Designation Material
Structure Sheet metal, ferrous material
Condenser, evaporator Aluminium, copper
Electrical components Copper, PVC, miscellaneous materials
Compressor Ferrous materials, copper and other materials
Refrigerant R134a / R452A
Refrigerant quantity 450 / 1170 g
Coating Epoxy compound
Tab. 1-1 List of materials

50.04.504 / 1.0
Copyright by GOVI GmbH 2021. The reproduction of this document or any part thereof is prohibited. We reserve the right to make technical changes during the course of further developments.
OPERATION MANUAL - Trailer Refrigeration Unit
arktik 1600N • 1600 N/T • 2000N • 2500N • 2000P • 2500 N/K • 2000 P/K
5
Page
2.1 Safety Messages and Safety Alert Symbols
DANGER!
Indicates a hazardous situation that, if not avoided, could result in
irreversible personal injury and even death.
WARNING!
Indicates a hazardous situation that, if not avoided, could result in
irreversible personal injury or even death under certain circumstances.
CAUTION!
Indicates a hazardous situation that, if not avoided, can result in
personal injury or damage to objects and the environment.
2.2 Other Terms and Symbols
Notices do not indicate safety-related content.
Notice
Provides useful information and helpful tips.
2. Safety Instructions

OPERATION MANUAL - Trailer Refrigeration Unit
arktik 1600N • 1600 N/T • 2000N • 2500N • 2000P • 2500 N/K • 2000 P/K
50.04.504 / 1.0
Copyright by GOVI GmbH 2021. The reproduction of this document or any part thereof is prohibited. We reserve the right to make technical changes during the course of further developments.
6
Page
2.3 Safety and Hazard Precautions
WARNING!
Electrical hazard!
Any work on the trailer refrigeration unit is allowed with
unplugged main plug only.
Protect the trailer refrigeration unit against being started up while
working on it by following suitable measures.
Never attempt to plug in or unplug the trailer refrigeration unit from the
power supply when your hands are wet.
WARNING!
Electrical hazard!
The following safety rules must be strictly observed before working on
the trailer refrigeration unit:
• Switch o.
• Prevent it from being switched back on again accidentally.
• Check that lines and equipment are without power.
• Ground and short circuit phases.
• Cover, partition or screen of adjacent line sections.
The electrical connection to the trailer refrigeration unit must be made
by a licensed electrician.
WARNING!
Hazard from toxic gas!
Thisrefrigerationunitcontainsauorocarbonrefrigerant,which,inthe
presenceofanopenameorelectricalshort,producestoxicgases
that are severe respiratory irritants capable of causing death.
The refrigerant tends to displace air and can cause oxygen depletion,
whichmayresultindeathbysuocation.
Be careful when working on the trailer refrigeration unit,
especially in any enclosed or conned area with a limited air
supply!
WARNING!
Fire and explosion hazard from ammable operating materials!
Avoidopenre,electricalsparksandignitionsources.
Do not smoke!
Observemeasuresforreandexplosionprotection.

50.04.504 / 1.0
Copyright by GOVI GmbH 2021. The reproduction of this document or any part thereof is prohibited. We reserve the right to make technical changes during the course of further developments.
OPERATION MANUAL - Trailer Refrigeration Unit
arktik 1600N • 1600 N/T • 2000N • 2500N • 2000P • 2500 N/K • 2000 P/K
7
Page
2.3 Safety and Hazard Precautions
WARNING!
Hazard from improper modications!
Do not drill any additional holes into the trailer refrigeration unit.
You may damage major parts. Holes accidentally drilled into
electrical wiring or refrigerant pipes can cause re or explosion.
WARNING!
Health hazard from refrigerant emissions!
During maintenance or repair work on the refrigerant circuit,
refrigerant emissions may occur. These emissions can be both liquid
and gaseous and pose a threat to humans and the environment.
In case of emissions or leaks in the refrigerant circuit, it is
mandatory to wear proper protective clothing as goggles,
respiratory masks and protective gloves.
CAUTION!
Burning hazard!
Components of the trailer refrigeration unit (such as condenser,
evaporator and tubes) may still be hot from operation.
Allowasucientcoolingtimeofthecomponentswhenworking
on the trailer refrigeration unit.
CAUTION!
Long-term environmental hazard!
Operating materials (refrigerant and refrigerant oil) are not
biodegradable. Observe the safety data sheet or operating
instructions of the materials used.
Operating materials and polluted components must
be disposed according to locally valid environmental
regulations.
CAUTION!
Injury hazard from rotating fan blades!
Keep your hands away from rotating fan blades.
Accidentalcontactwithfanbladesʼsharpedgescancausesevere
personal injury.

OPERATION MANUAL - Trailer Refrigeration Unit
arktik 1600N • 1600 N/T • 2000N • 2500N • 2000P • 2500 N/K • 2000 P/K
50.04.504 / 1.0
Copyright by GOVI GmbH 2021. The reproduction of this document or any part thereof is prohibited. We reserve the right to make technical changes during the course of further developments.
8
Page
2.4 Safety Precautions Concerning the Refrigerant
Hydrouorocarbonrefrigerantsareclassiedassaferefrigerants.
However, certain precautions must be observed during the operation,
installation and maintenance of the trailer refrigeration unit.
When released to the atmosphere in the liquid state,
hydrouorocarbonrefrigerantsevaporatecausingrapidfreezing.
In contact with parts of the human body, they can cause severe
frostbites.
Hydrouorocarbonrefrigerantsmaygeneratehazardousgases,
which,inthepresenceofanopenameorelectricalshort,aresevere
respiratory irritants and may have fatal consequences.
2.4.1 First Aid
Intheeventoffrostbite,youshouldgenerallyprotecttheaected
area from further injury or contact with the refrigerant and if
necessary seek medical advice.
Contact of refrigerant or refrigerant oil with the eyes:
In case of contact with the refrigerant or refrigerant oil, immediately
usheyeswithlargeamountsoflukewarmwater(foratleast15
minutes) and get prompt medical attention.
Frostbite of the skin:
• Remove clothing and shoes contaminated with refrigerant.
•Flushtheaectedareawithlargeamountsoflukewarmwaterfora
long time.
• Do not apply heat (e.g. by rubbing or using a hot water bottle).
•Getimmediatemedicalattention.Looselybandagefrost-biteburns
with dry, sterile, sizeable dressing to protect from infection or injury.
Inhalation of refrigerant:
Get immediate medical attention.
Bring the person to fresh air and, if necessary, carry out resuscitation
measures.
2.4.2 Environmental Considerations
GOVI trailer refrigeration units are shipped with a suitable charge of
refrigerant R452A / R134a.
Incaseoferrorsintherefrigerantcircuitoruidleakingoutofthe
trailer refrigeration unit, the unit must be checked by a specialist and
be properly repaired. Under no circumstances the refrigerant shall be
vented into the atmosphere.
Accurately read the Safety and Hazard Precautions in section
2.3 Safety and Hazard Precautions, as well as the data sheet for
the refrigerant R452A / R134a provided by the manu- facturer.
Defectiveandreclaimedrefrigerationunites/suckeduidsmustbe
disposed according to the relevant environmental regulations.

50.04.504 / 1.0
Copyright by GOVI GmbH 2021. The reproduction of this document or any part thereof is prohibited. We reserve the right to make technical changes during the course of further developments.
OPERATION MANUAL - Trailer Refrigeration Unit
arktik 1600N • 1600 N/T • 2000N • 2500N • 2000P • 2500 N/K • 2000 P/K
9
Page
2.5 Intended Use
This trailer refrigeration unit is designed for refrigerated trailers at
locationswithoutexplosionorrehazards.Forthatpurpose,the
trailer refrigeration unit is mounted stationary at the front wall of the
refrigerated trailer by a mechanical fasting system (not within the
scope of delivery).
At outside temperatures between -20°C and +40°C the trailer
refrigeration unit enables inside temperatures from 0°C to 10°C.
• The trailer refrigeration unit is not determined for operation in AP.PE
EEx (places with explosion hazard).
• The trailer refrigeration unit is not designed to be used in places with
rehazard.
• The trailer refrigeration unit is not equipped with reinforced
electrical or mechanical protective elements to withstand aggressive
atmospheric conditions.
Ensure good ventilation of the trailer refrigeration unit when placing the
trailer. Ensure proper air circulation and good access for maintenance
work when indicated.
Do not expose the trailer refrigeration unit to direct sunlight.
Ensure proper air circulation inside the refrigeration unit when loading
the trainer. Do not block the evaporator. Avoid the insertion of heat
sources in the refrigeration unit.
The trailer is designed for no other purpose than the one described
above. Any other use is considered improper, for which it is prohibited
orrequiresthemanufacturerʼsapproval.
TheIntendedUsealsoincludescompliancewiththespecied
maintenance and repair work, see section 10 Maintenance.

OPERATION MANUAL - Trailer Refrigeration Unit
arktik 1600N • 1600 N/T • 2000N • 2500N • 2000P • 2500 N/K • 2000 P/K
50.04.504 / 1.0
Copyright by GOVI GmbH 2021. The reproduction of this document or any part thereof is prohibited. We reserve the right to make technical changes during the course of further developments.
10
Page
The trailer refrigeration unit consists of a self-supporting chassis
made of galvanized plate and a main cover made of ABS, with paint in
standardcolourRAL9010.
3. Technical Data
Fig. 3-1 Nameplate
The serial numbers of the trailer refrigeration unit are on the nameplate,
together with other important technical data. The nameplate is on
the right-hand side of the main cover in the proximity of the electrical
connection.
To ensure a fast and smooth processing of your requests, please
mention the serial number of the trailer refrigeration unit when asking
technical queries.

50.04.504 / 1.0
Copyright by GOVI GmbH 2021. The reproduction of this document or any part thereof is prohibited. We reserve the right to make technical changes during the course of further developments.
OPERATION MANUAL - Trailer Refrigeration Unit
arktik 1600N • 1600 N/T • 2000N • 2500N • 2000P • 2500 N/K • 2000 P/K
11
Page
Fig. 3-2 Dimensions
arktik 1600N • 1600N/T • 2000N
arktik 2500N • 2500N/K • 2000P • 2000P/K

OPERATION MANUAL - Trailer Refrigeration Unit
arktik 1600N • 1600 N/T • 2000N • 2500N • 2000P • 2500 N/K • 2000 P/K
50.04.504 / 1.0
Copyright by GOVI GmbH 2021. The reproduction of this document or any part thereof is prohibited. We reserve the right to make technical changes during the course of further developments.
12
Page
CFC-free refrigerant R134a / CFC-free refrigerant R452A
N = Normal refrigeration
N/T = Normal refrigeration at high outside temperature
P = Polytemperature
K = Climate heater (ensuring the desired temperature in winter)
The refrigeration capacity is based on the following operating
conditions: Outside temperature 30 °C, RH 50% / * Outside
temperature 40 °C, RH 50%
We recommend an insulation with a k value of 0.2 W/m²K
Tab. 3-1 Technical data
Description Unit arktik
1600N
arktik
1600N/T
arktik
2000N
arktik
2500N
arktik
2500N/K
arktik
2000P
arktik
2000P/K
Refrigerated trailer
internal temperature °C T=2°C T=2°C T=2°C T=2°C T=2°C T=2 °C/
-20 °C
T=2 °C/
-20 °C
Power supply V230 230 230 230 230 230 230
Frequency Hz 50 50 50 50 50 50 50
Cooling capacity W1600 1470* 2050 2500 2500 2050/1500 2050/1500
Heating capacity W-/- -/- -/- -/- 1600 -/- 1600
Power consuption W855 855 1260 1200 1200 1200/1000 1200/1000
Current
consumption LRA A19,8 19,8 29 32 32 32 32
Current
consumption FLA A4,8 4,8 5,7 7 7 7,0/6,5 7,0/6,5
Defrosting W340 340 340 600 600 1230 1230
Air flow evaporator m3/h 750 750 750 1100 1100 1100 1100
Air flow condenser m3/h 750 1100 1100 1100 1100 1100 1100
Protection class,
mounting side IP 54 54 54 54 54 54 54
Refrigerant Typ R134a R134a R134a R452A R452A R452A R452A
Refrigerant
quantity g 450 450 550 800 800 1170 1170
Max. operating
temperature °C 40 45 40 40 40 40 40
Weight kg 55 55 63 63 63 63 63
Colour RAL 9010 9010 9010 9010 9010 9010 9010

50.04.504 / 1.0
Copyright by GOVI GmbH 2021. The reproduction of this document or any part thereof is prohibited. We reserve the right to make technical changes during the course of further developments.
OPERATION MANUAL - Trailer Refrigeration Unit
arktik 1600N • 1600 N/T • 2000N • 2500N • 2000P • 2500 N/K • 2000 P/K
13
Page
4.1 Package
For safe transportation, the trailer refrigeration unit is securely packed
in a box mounted on pallets.
CAUTION!
Damaged appliances can cause skin injuries and property
damage due to leakage of the refrigerant.
In case of severe external damage to the package and/or on
the trailer refrigeration unit, contact immediately your local
GOVI dealer for assistance.
Do not start with the installation of the trailer refrigeration unit and do
not put it into operation.
1. Upon delivery place the pallet and box on a level ground. Immediately
inspect the box and the trailer refrigeration unit for any damage.
2. Inform the carrier about any damage you have discovered.
3. Take pictures of the damage and document them immediately on the
bill of delivery.
4. Check the contents of the box for completeness.
5.Lookforloosepartsthatmaybeintegralpartofthedelivery,before
disposing of the package.
4. 4 Package, Transportation
and Storage
1. Spanner
2. Coupling
3.Lamp
4. Bulb
5. Flyer with safety instructions
and QR code for the operating
manual
Fig. 4-1 Box
3
1
24
5

OPERATION MANUAL - Trailer Refrigeration Unit
arktik 1600N • 1600 N/T • 2000N • 2500N • 2000P • 2500 N/K • 2000 P/K
50.04.504 / 1.0
Copyright by GOVI GmbH 2021. The reproduction of this document or any part thereof is prohibited. We reserve the right to make technical changes during the course of further developments.
14
Page
4.2 Transport
CAUTION!
Risk of equipment damage!
The trailer refrigeration unit must be transported
horizontally.
The trailer refrigeration unit must have been in a horizontal position at
least six hours prior to its commissioning.
• Only use suitable lifting equipment for lifting and transport of
thetrailerrefrigerationunit.Lookatsection 3 Technical Data for
information about the weight.
•Lifttherefrigerationunitfortrailersaccordingtosection 6.4
Installation of the Trailer Refrigeration Unit.
4.3 Storage
Observe the following when storing the trailer refrigeration unit:
• The trailer refrigeration unit must be stored horizontally, see Fig. 4-2.
• The storage temperature must not exceed 60 °C.
• The trailer refrigeration unit must not be stored in an aggressive
environment.
• Direct sunlight at the storage location must be avoided.
Fig. 4-2 Transport and storage

50.04.504 / 1.0
Copyright by GOVI GmbH 2021. The reproduction of this document or any part thereof is prohibited. We reserve the right to make technical changes during the course of further developments.
OPERATION MANUAL - Trailer Refrigeration Unit
arktik 1600N • 1600 N/T • 2000N • 2500N • 2000P • 2500 N/K • 2000 P/K
15
Page
1. Compressor
2. Condenser fan
3. Condenser
4. Throttle valve
5. Evaporator fan
6. Evaporator
5.System Description
Fig. 5-1 Functional diagram The unit functioning is based on the cooling cycle principle: heat
transfer occurs by means of a refrigerant, which absorbs heat in the
evaporator and then releases it in the condenser. All this takes place
within a closed loop. The refrigerant is pressurised by an electrically
drivencompressor,uidisedinthecondenser,atomisedbymeansofa
throttle valve and evaporated in the evaporator.
The evaporator is located inside the refrigerated trailer, while the
condenser on the outside.
The trailer refrigeration unit is equipped with a forced-ventilated
condenser and evaporator, axial fans and electronic temperature
control.

OPERATION MANUAL - Trailer Refrigeration Unit
arktik 1600N • 1600 N/T • 2000N • 2500N • 2000P • 2500 N/K • 2000 P/K
50.04.504 / 1.0
Copyright by GOVI GmbH 2021. The reproduction of this document or any part thereof is prohibited. We reserve the right to make technical changes during the course of further developments.
16
Page
1 2
1. Main cover
2. Evaporator (with refrigerant
in the system)
3. Protection cover
4. Air intake (do not obstruct!)
5. Air outlet (do not obstruct!)
6. Condenser (with refrigerant
in the system)
Fig. 5-2 Overview of the trailer refrigeration unit
Main cover (1)
Evaporator (2) and
condenser (6)
Protection cover (3)
and setting of nominal
temperature
Air intake (4) and
air outlet (5)
The main cover (1) covers the outer parts of the trailer
refrigeration unit.
In the evaporator (2) heat is absorbed by the refrigerant, which is
released again in the condenser (6).
The protection cover (3) shields the control unit from harsh weather
and impedes unintended changes of the settings.
The nominal temperature is set according to section 9.2 Setting
Nominal Temperature.
The air intake (4) and air outlet (5) must always be kept free.
They must not be covered or obstructed.
6
4
5
3

50.04.504 / 1.0
Copyright by GOVI GmbH 2021. The reproduction of this document or any part thereof is prohibited. We reserve the right to make technical changes during the course of further developments.
OPERATION MANUAL - Trailer Refrigeration Unit
arktik 1600N • 1600 N/T • 2000N • 2500N • 2000P • 2500 N/K • 2000 P/K
17
Page
6. Installation 6.1 Conditions for Installation
1. Read this manual carefully in order to understand how to properly
perform the installation.
2. Verify that the trailer refrigeration unit is delivered according to your
order, is in good condition and has no visible damages.
3. Check that all necessary tools and all additionally required parts are
not missing and that are in good operating condition.
4. Verify that the installation site of the trailer refrigeration unit provides
aatsurfacewithoutunevenness,whichmaycausevibrations.
5. Check that the front wall of the trailer refrigeration unit is able to
adequately support its weight.
6. Make sure that the loading crane or lifting device, and the complete
liftingcablesareofsucientsizetosupporttheweightofthetrailer
refrigerationunits.Lookatsection 3 Technical Data for information
about the weight.
7. Note that the power supply of the trailer refrigeration unit cannot be
connected before the installation of the unit and its accessories has
been completed.
8. Provideprotectiontothetrailerʼswallsand/orinternalpartsto
prevent damage by swarf and alike during the installation process.
6.2 Additional Parts and Equipment
Because of the wide variety of installation options available, the
trailer refrigeration unit is not shipped with all parts needed for every
possible installation situation. The installer needs to make sure that the
following parts are available.
We recommend keeping the following additional parts ready in a box
before starting the installation process:
2 assembly eyelets M8
1 condensed water drain hose
with an internal 15-mm diameter and suitable length.

OPERATION MANUAL - Trailer Refrigeration Unit
arktik 1600N • 1600 N/T • 2000N • 2500N • 2000P • 2500 N/K • 2000 P/K
50.04.504 / 1.0
Copyright by GOVI GmbH 2021. The reproduction of this document or any part thereof is prohibited. We reserve the right to make technical changes during the course of further developments.
18
Page
6.3.1 General Preparation
1. Place the refrigerated trailer and trailer refrigeration unit side by side
on a dry and clean level ground.
2. Verify that the trailer is in horizontal position.
3. Make sure that the contact area between its front wall and the trailer
refrigeration unit is free from impurities
4. Remove all obstacles from the installation area.
5. Prepare all required tools and equipment and place them in a safe
place easily accessible from the installation area.
6. Verify that the PU seal (1) at the backside of the trailer refrigeration
unit is available and intact.
1
6.3 Preparatory Activities
Fig. 6-1 PU seal of the
trailer refrigeration unit
1. PU-Seal

50.04.504 / 1.0
Copyright by GOVI GmbH 2021. The reproduction of this document or any part thereof is prohibited. We reserve the right to make technical changes during the course of further developments.
OPERATION MANUAL - Trailer Refrigeration Unit
arktik 1600N • 1600 N/T • 2000N • 2500N • 2000P • 2500 N/K • 2000 P/K
19
Page
6.3.2 Installation Opening of Trailer Wall
7. Prepare the wall opening together with 6 drill holes for the fastening
elements in the middle of the front wall of the trailer. Make sure that
the minimum size for proper operation of the trailer refrigeration unit
is observed, see Fig. 6 2.
6.4 Installation of the Trailer Refrigeration Unit
Fig. 6-2 Dimensions of the
trailer wall opening
Fig. 6-3 Attachment points
of the trailer refrigeration
unit
1. Eye bolts
2. Carrying rope
3. Spring hook
arktik 1600N • 1600N/T • 2000N
arktik 2500 • 2500N/K • 2000P • 2000P/K
Roof
Side wall
Side wall
Roof
Side wall
Side wall
1 1 2 3
arktik 1600N • 1600N/T • 2000N
arktik 2500 • 2500N/K • 2000P • 2000P/K
Roof
Side wall
Side wall
Roof
Side wall
Side wall

OPERATION MANUAL - Trailer Refrigeration Unit
arktik 1600N • 1600 N/T • 2000N • 2500N • 2000P • 2500 N/K • 2000 P/K
50.04.504 / 1.0
Copyright by GOVI GmbH 2021. The reproduction of this document or any part thereof is prohibited. We reserve the right to make technical changes during the course of further developments.
20
Page
CAUTION!
Risk of equipment damage!
Without the main cover, the individual components of the
trailer refrigeration unit are vulnerable to damage during
the installation.
Leave the main cover during the installation.
1. Remove the hexagon head screws from the mounting holes of the
main cover on the top of the trailer refrigeration unit one by one and
insert two eye bolts (not included) in the free holes.
WARNING!
Injury hazard!
The weight of the trailer refrigeration unit is approximately 63 kg.
Always wear a helmet when lifting and positioning it.
Use only suitable and approved tools.
You must use both lifting points (eye bolts).
2. Attach2sucientdimensionedcarryingropes(2)atboth
eye bolts (1).
CAUTION!
Risk of equipment damage!
The trailer refrigeration unit must be transported horizontally.
The trailer refrigeration unit must have been in a horizontal
position at least six hours prior to its commissioning.
Fig. 6-4 Mounting alignment
This manual suits for next models
6
Table of contents
Other GOVI Refrigerator manuals