BEDROCK TRADITIONAL WITH GLOWFIRE™ LOGS BURNER INSTALLATION & OPERATION MANUAL
GRANDCANYONGASLOGS.COM - 05_2023
GENERAL INSTRUCTIONS
5
DO NOT REMOVE THIS LABEL
See installation & operating instructions for this model.
Contact local building officials about restrictions and
installation specifications in your area.
DATE
OF MFG. SERIAL
#
MODEL: LDBT L-EN 48 60 72
HIGH BTU/HR (kW): 62,000 (18.17kW) 95,000 (27.84kW) 95,000 (27.84kW)
LOW BTU/HR (kW): 45,000 (13.19kW) 60,000 (17.58kW) 60,000 (17.58kW)
VENTED DECORATIVE GAS APPLIANCE: NOT A SOURCE OF HEAT; NOT FOR USE WITH SOLID FUEL.
APPAREIL DÉCORATIF À GAZ VENTILÉ: PAS UNE SOURCE DE CHALEUR; NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE.
THIS APPLIANCE NEEDS FRESH AIR FOR SAFE OPERATION AND MUST BE INSTALLED
SO THERE ARE PROVISIONS FOR ADEQUATE COMBUSTION AND VENTILATION AIR.
CET APPAREIL A BESOIN D'AIR FRAIS POUR UN FONCTIONNEMENT SÉCURISÉ ET DOIT ÊTRE INSTALLÉ POUR IL Y A DES
DISPOSITIONS POUR UN AIR DE COMBUSTION ET DE VENTILATION ADÉQUAT.
This appliance is not for installation in manufactured homes. Cet appareil n'est pas destiné à être installé dans des maisons préfabriquées.
The installation, including provisions for combustion, ventilation air, and required minimum permanent vent opening,
must conform with National Fuel Gas Code (ANSI Z223.1/NFPA 54) and applicable local building codes.
L'installation, y compris les dispositions pour la combustion, l'air de ventilation et l'ouverture de ventilation permanente minimale requise,
doit être conforme au National Fuel Gas Code (ANSI Z223.1 / NFPA 54) et aux codes du bâtiment locaux applicables.
WARNING: This gas appliance must not be connected to a chimney fuel servicing a solid fuel burning appliance.
AVERTISSEMENT: Cet appareil à gaz ne doit pas être raccordé à un combustible
de cheminée desservant un appareil à combustible solide.
WARNING: THIS FIREPLACE IS NOT INTENDED FOR BURNING SOLID FUELS.
AVERTISSEMENT: CE FOYER N'EST PAS DESTINÉ À BRÛLER DES COMBUSTIBLES SOLIDES.
NG Models
Altitude
Input
Reduced Input
P4
Manifold Pressure: 3.5" w.c.(NG)
Minimum Supply Pressure: 5" w.c. (NG)
Maximum Supply Pressure: 7"* w.c. (NG)
Pression au Collecteur: .87wPA d’une colonne d’eau (GN)
Pression d’Alimentation Min.: 1.25wPA d’une colonne d’eau (GN)
Pression d’Alimentation Max.: 3.5wPA ** d’une colonne d’eau (GN) **
Maximum inlet pressure not to exceed 13".
Minimum clearance to combustible materials: Top, sides & back:
per standoff spacers for framing and finishing materials. For
non-combustible framing and finishing materials, see installation manual.
LP Models
Élévation
Alimentation / Alimentation Réduite
P4
Manifold Pressure: 10" w.c. (LP)
Minimum Supply Pressure: 11" w.c. (LP)
Max. Supply Pressure: 14"* w.c. (LP)
Pression au Collecteur: 2.40wPA d’une colonne d’eau (LP)
Pression d’Alimentation Min.: 2.74wPA d’une colonne d’eau (LP)
Pression d’Alimentation Max.: 3.5wPA * d’une colonne d’eau (LP)
** Pression d’alimentation maximale ne devait pas dépasser
3.5wPA. Dégagements minimaux des matériaux combustibles:
Dessus, côtés et arrière: selon les espaceurs de dégagements
pour les matériaux d’ossature selon le manuel du
propriétaire pour les matériaux de finition
MANIFOLD PRESSURE:
ELECTRICAL RATING: 120V/60HZ
GAS TYPE: NATURALGAS /LIQUID PROPANE
MODEL: LDBT L-EP 48 60 72
HIGH BTU/HR (kW): 62,000 (18.17kW) 75,000 (21.98kW) 75,000 (21.98kW)
LOW BTU/HR (kW): 30,000 (8.79kW) 40,000 (11.72kW) 40,000 (11.72kW)
ANSI-Z21 60-2017
CSA 2.26-2017
Decorative gas appliances
for installation in solid-fuel
burning fireplaces.
REPORT NO.
(F23-120)3515 E. Atlanta Ave. Phoenix, AZ 85040
LINE VOLTAGE TESTED &