3. aIr IntaKe SyStem
There are many possible ways to accomplish the delivery of
outside air to the rebox space and combustion area. Like
the Chimney Chase, you should plan ahead for the Air Intake
System installation.
Three common methods of installation include: Outside Wall
Venting, Chimney Chase Venting and Roof Venting.
Outside Wall Venting is used when the replace is being
installed on an outside wall as shown in gure 6 - Outside
Wall Venting. It does not matter weather it is the wall on
the right or the wall on the left, each will work equally
well. The Wall Vent should be placed at least 12” above
the oor on the available exterior wall. The Wall Vent must
be placed within the Firebox Assembly area behind the
Face Frame. Cut out a 6” diameter circle on the wall and
insert the vent. Secure the outside of the vent to the wall
using (4) #8 x 1-1/2” hex head self-drilling screws.
Chimney Chase Venting is used when an exterior wall
is not available as shown in gure 7 - Chimney Chase
Venting. In this conguration the Wall Vent is installed
into the Chimney Chase and a 6” Flex Aluminum Duct will
run down the inside of the Chimney Chase to the rebox
area. Draw a 6” diameter circle on the chase, cut out the
circle, and insert the Wall Vent. Secure the outside of
the vent to the wall using (4) #8 x 1-1/2” hex head self-
drilling screws. Inside the Chimney Chase attach the 6”
Flex Aluminum Duct to the Wall Vent sleeve, secure with
screws, and stretch the Flex Aluminum Duct along the
corner of the Chimney Chase to about 12” above the oor
behind the rebox.
Roof Venting can be used in nearly any installation. A
6” hole is cut through the roof surface near the Chimney
location. A short length of 6” single wall pipe is installed
with roof ashing and a cap to protect against rain and
snow. Attach the 6” Flex Aluminum Duct to the Wall Vent
sleeve, secure with screws, and stretch the Flex Aluminum
Duct along the corner of the Chimney Chase to about 12”
above the oor near the base of the rebox. A typical roof
vent installation is shown in gure 8 - Pitched Roof Vent.