User’s Manual
PD Series
O/E CONVERTER
650nm version
Model
SPD-1 650
SPD-2 650
Graviton INC
https://www.graviton.co.jp/index_En.html
Page 1
Contents of this package
The contents of this package are listed below.
Please contact immediately the shop you purchased this product, if there is any
missing item s found.
①②③
④
①O/E converter ④User’s Manual(this manual)
②Power Cable Assembly
③Auxiliary Power Connector
◇Please keep original packaging, in case of re-shipping.
Page 3
Introduction
Thank you for purchasing PD Series O/E Converter.
PD Series is Optical to Electric signal converter and has following feature.
・SPD-1 650:500mV/mW SPD-2 650:1000mV/mW (@ 650nm Wave Length, 50/125
GI Fiber)
・Wide Frequency Range
DC~1200MHz Flatness +0.5 –3.0[dB electrical]
・Standard FC optical connector
(Optional SC, F05, SMA, and ST connector are also available.)
・Standard BNC plug
Able to connect directly to an oscilloscope, a spectrum analyzer etc.
・Able to get DC power from instruments through included Power Cable Assembly.
It is not guaranteed that power cable corresponds to all instruments.
・Able to use for instrumentation of lightwave products, optical links or
other various applications.
Please read this user’s manual carefully and use it appropriately according
to this manual, will make this product useful for development of light wave
equipments, lightwave communication converter or other various
applications.
◇Do not re-produce or re-publishing a part or all this manual without
written permission from Graviton Inc.
◇This manual is subject to change without notice.
◇Please follow exporting regulations/rules in individual countries when
exporting this product to other countries.
Page 2
Front and rear panel view
①Power switch
This switch is for controlling power. Please on/off this switch after
connecting power cable assembly to power connector(②) also keep this switch
off when not in use.
②Power input connector
The power can be supplied from probe power connector that equipped with an
instrument through the Power Cable Assembly. Or, alternately, external
regulated power supply (not included) can be used through the Auxiliary Power
Connector. Power supply voltage for PD series is±15[V]. Applying over and/or
wrong polarity may cause permanent damage. Please refer the specification
in page 7 for current consumption and page 5 for the detail of the power
connection.
③Optical signal input connector
Light signal supplied through this FC connector is up to -1[dBm] for SPD-1
650 and up to -4[dBm] for SPD-2 650. Please do not apply 10dBm or higher light
signal. It may cause permanent damage.
④Electrical signal output connector
50[Ω] input impedance with wide frequency range instruments is suitable to
observe light signal. Recommended to use wider frequency range instruments
to withdraw full spec.(DC~1200MHz SPD-1 650・SPD-2 650)
Page 4