TABLE OF CONTENTS
What’s included.....................................................................................................4
Installation warnings............................................................................................5
Doors.......................................................................................................................6
Door handles.........................................................................................................8
Side panels...........................................................................................................10
Caster and levelers.............................................................................................11
Top and bottom panels ....................................................................................12
Mounting rails......................................................................................................13
PDU brackets, standard....................................................................................14
OPTIONAL ASSECCORIES
PDU brackets, specialty.....................................................................................16
Cable management ngers..............................................................................19
Front to rear cable trough................................................................................19
Vertical cable manager......................................................................................20
Cable bar kits.......................................................................................................21
Top cable trough.................................................................................................23
Ladder rack brackets.........................................................................................24
External cable manager/side car....................................................................25
Brush grommet rail kit ......................................................................................26
Brush grommet for cable pass-thru ..............................................................27
Air manager..........................................................................................................28
Exhaust chimney.................................................................................................30
Bae kits ..............................................................................................................31
Networking/Ganging..........................................................................................32
Grounding/Copper bus bar .............................................................................33

3
PREFACE
This manual is provided to prevent service personnel from committing
an act that results in the risk of re, electric shock, or injury to persons.
Only trained service personnel should receive, unpack, and assemble
ES cabinets (UL60950 -1/UL2416 ES Series Equipment Cabinet/Rack).
In addition, only trained service personnel should install equipment in
cabinets.
SAFETY SYMBOLS USED IN THIS MANUAL
This manual provides general safety guidelines to be observed during
installation, operation, and maintenance of the ES cabinet.
WARNING: Failure to follow directions in the warning could result in
injury to persons or loss of life.
CAUTION: Failure to follow directions in the caution could result in
damage to equipment or storage data.
SAFETY CONSIDERATIONS
WARNING: Improper handling and use of the ES cabinet could result
in equipment damage, serious injury, or possible death.
Only trained service personnel should be used to remove the cabinet
from the shipping pallet. Also, be sure you have a sucient number of
service personnel. Do not attempt to move cabinets by yourself.
Only UL® Listed ITE (Information Technology Equipment) units should
be installed inside the ES cabinet.
Be sure to read and follow all individual manufacturer equipment
manuals for safety and installation instructions.
Proper spacing is required when installing electrical equipment
to avoid electrical shock. Maintain minimum spacing between the
accessories and components and the computer cabinet assembly for
safe operation of the equipment when installed in accordance with the
National Electric Code ANSI/NFPA 70-1999.
The ambient temperature operating range for the ES cabinet and
accessories is +50 to +95° F (+10 to +35° C).
The non-operating temperature is -4 to +140° F (-20 to +60° C).

4
SERVICE
ES cabinets should be repaired by personnel trained by Great Lakes,
or returned to Great Lakes for repair or replacement. Contact Great
Lakes Technical Support at 814.734.7303 or at GreatCabinets.com
WHAT’S INCLUDED
• ES unit (assembled)
• Keys as needed (depending on conguration)
• (50) M6 cage nuts (3/8" square) and M6 screws
(#10-32 tapped rails available, must be specied at time of order)
• This user’s manual
This user’s manual applies to the following Great Lakes
ES cabinets:
1Weight capacity of 24"W ES cabinet: 2000 lbs.; 3300 lbs. with HD Kit.
HD Kit can only be factory installed. Must be specied at the time the
cabinet is ordered.
2Weight capacity of 30/32"W ES cabinet: 3300 lbs.
Part No. RMU H W D
GL980ES-3248252 98" 32" 48"
GL910ES-3048248 91" 30" 48"
GL910ES-3042248 91" 30" 42"
GL910ES-2448148 91" 24" 48"
GL910ES-2442148 91" 24" 42"
GL840ES-3248244 84" 32" 48"
GL840ES-3242244 84" 32" 42"
GL840ES-3048244 84" 30" 48"
GL840ES-3042244 84" 30" 42"
GL840ES-2448144 84" 24" 48"
GL840ES-2442144 84" 24" 42"
GL790ES-3048242 79" 30" 48"
GL790ES-3042242 79" 30" 42"
GL790ES-2448142 79" 24" 48"
GL790ES-2442142 79" 24" 42"
GL480ES-2442124 48" 24" 42"

5
INSTALLATION
Receiving, Unpacking, and Removing the ES cabinet from the
shipping pallet
Inspect and report any damage before receiving. Unpack the cabinet
by carefully removing the corrugated carton and corners. Avoid
damaging the cabinet when removing packaging.
WARNING: Only trained service personnel should be used to remove
the cabinet from the pallet. Also, be sure you have a sucient number
of service personnel. Do not attempt to move cabinets by yourself.
WARNING: Be careful when moving cabinets before installation.
Sudden stops and starts, excessive force, obstructed routes, and
uneven oor surfaces may cause the cabinet to topple over.
Loading Equipment
WARNING: Only install equipment after the ES cabinet has been
properly secured. Do not move the ES cabinet assembly while loaded.
Once in place at the desired/intended location, deploy the leveling feet
for maximum stability.
Rated or maximum load capacity for the ES cabinet is 2000 pounds (for
24"W cabinet; 3300 lbs. with HD Kit installed) or 3300 lbs. (for 30/32"W
cabinet) on the oor or on leveling glides.
To maintain a uniform distribution of the mechanical load in the ES
cabinet, load the heaviest equipment rst, at the bottom of the
ES cabinet and load the lighter units at the top.

6
Align all three
hinges to
attach door
DOORS
• BEFORE REMOVING,
pull apart the quick-disconnect grounding wires
• TO REMOVE,
open the door beyond 90o, grasp the door with both hands and lift
upward, when the door is free of all three hinge pins, pull the door
away from the cabinet
• TO ATTACH,
align all three hinges of the door to their respective hinge pins on the
cabinet and slowly slide the door down until seated
Open door beyond
90o; lift straight up

7
Reversible hinge (female)
Flat head phillips screw # 10-32 x 1/2
DOOR DETAIL
Flat head phillips screw # 10-32 x 1/2
Reversible hinge (male)
Pivot washer
REVERSING THE DOOR
• Front and rear doors are installed right-hand hinge as standard from
the manufacturer
• TO REVERSE,
- Remove hinges and handle from door
- Rotate door 180o
- Reinstall hinges and handle after rotating both 180o(see page 8)
FRAME DETAIL

8
DOOR HANDLES
• Mesh contour doors come standard with a locking lever handle (see
install below)
• The lever handle on mesh contour doors can be interchanged with a
swing handle (see install, page 9)
• All other doors (mesh, steel, plexi, etc.) come standard with a
locking swing handle (see install, page 9); swing handles cannot be
interchanged with a lever handle
• If a handle is ordered separately, the handle can be swapped in the
eld. When interchanging the door handle, additional hardware may
be required (and will ship with the handle)
ASSEMBLY OF LEVER HANDLE ON MESH CONTOUR DOORS
Top View
1" THK
Deep cam
Handle keeper
spring clip, lift to release
Left Side View Front View
Top handle
hook, insert rst

9
Top View
1" THK
Screw-on
keeper
Assembly of swing handle on mesh contour doors
ASSEMBLY OF SWING HANDLE ON STANDARD MESH, STEEL, PLEXI
AND PERIMETER VENTED DOORS
Left Side
View Front View
Deep cam Bottom
of handle
hook,
insert rst
Top View
.5"
THK
Left Side
View Front View
Screw-on
keeper
Flat cam
Bottom of
handle hook,
insert rst

10
SIDE PANELS
• BEFORE REMOVING,
pull apart the quick-disconnect grounding wires and unlock the
side panel
•TO REMOVE
- Squeeze the quick-release latches toward each other
- Tilt the top of the side panel out slightly
- Lift the side panel up a couple of inches until it is free from the two
tabs at the bottom of the cabinet frame
•TO INSTALL
- Engage the side panel with the two tabs at the bottom of the frame
- Push the panel fully into the frame
- Ensure quick-release latches engage with slots on the side of the
frame

11
CASTER AND LEVELER MOUNTING
CAUTION
• To install casters or levelers, the cabinet must be tipped onto its
side. The cabinet can be very heavy; several people will be
required in this process. Please practice safe lifting techniques.
• DO NOT lay the cabinet on its front or back, this may damage the
door hinges.
• Before tipping, remove the side panels and doors to reduce cabinet
weight and avoid damage to handles.
•TO INSTALL
- Place cabinet on its side
- Pass a plate caster over four threaded studs located in one of the
recessed areas in the bottom of the cabinet
- Thread (1) 5/16-18 hex nut onto each stud and tighten with a 1/2"
socket or nut driver
- Repeat the above steps for the three remaining casters
- Install leveling glides (7209-HD) at this time if they were ordered
with the cabinet
1
1
2
2
3
3
4
4
5
5
6
6
A A
B B
C C
D D
.75 Thru holes (6 total)
Counter clockwise rotation will adjust
the leveling glide up
Clockwise rotation will adjust the
leveling glide down
(4) 1/2 -13 Threaded holes
(4) Adjustable levelers
Swivel caster
5/16-18 Threaded studs
5/16-18 Hex nuts

12
TOP & BOTTOM PANELS
TOP PANEL
• Top panel is installed at the manufacturer
• TO REMOVE, unscrew the four #10-32 x 1/2" lg
screws, lift o the top panel
• TO INSTALL, insert four #10-32 x 1/2" lg
screws
TPES-S TPES-P TPES-F TPES-F10 TPES-2F10 TPES-B
Solid Perforated Three, One, 10" 550 Two, 10" 550 Brush
75 CFM Fans CFM Fan CFM Fans Grommet
6 top panel options
Use push
clips to
secure in
place (2)
Align Ø 0.25 holes and ush with
stiener (2 places) Magnetic strip
holds bottom of
panel to cabinet
Panel slides into bottom rear of cabinet
between rear stiener and rear door jamb
A
BOTTOM PANEL
• Bottom Panel (brush grommet and solid) is installed at the
manufacturer if ordered with the cabinet
• Panels come in two sections: one for the large center opening and
one for the rear opening
•TO INSTALL
- Center section: Lay the large bottom panel over the opening
center section in the bottom of the cabinet with the magnetic strip
should face the bottom of the cabinet
- Rear section: Align the holes in the rear bottom panel with holes in
the rear of the cabinet; secure with push-button rivets
- If cinch straps are installed in the bottom of the cabinet, straps
must be removed before installing rear bottom panel

13
FMP
Slide Nut
1/4" - 20 Hex
Head Bolt
Slide nut
#10-32 x 1/4"
Screw
#10-32 x 1/4”
Screw
32"W Rail
24", 30" & 32"W Rails
(Top & Bottom)
MOUNTING RAILS
• Two pairs of 12 gauge steel, powder coated
vertical mounting rails for 19" EIA 310-E
equipment are installed in each cabinet
• 30 and 32"W ES cabinet can be congured to
23" EIA mounting with an optional replacement
bracket set
• Universal 3/8" sq. (M6) rails are standard;
Tapped #10-32 rails are available and will be
installed if specied at time of order
• Rack Mount Units (RMU) are marked on all rails
• Flexible Mounting Prole (FMP), round cable pass
through holes, and vertical and horizontal cable
tie down slots can be found on all rails
RAIL ADJUSTMENT
• Do NOT attempt to adjust rails once equipment has been loaded
• Rails are attached using a sliding nut plate and a 1/4" -20 hex head
bolt
• TO ADJUST, loosen the top and bottom bolts on the horizontals with
a 3/8" drive socket
• 32"W cabinets feature a center intermediate, loosen the screw on
the intermediate bracket
• Slide rails to appropriate placement and tighten all hardware to
secure rails
Center
Intermediate
Top horizontal

14
POWER
When using power distribution units (PDUs), each PDU should be
connected to a committed branch circuit that is rated for the
continuous load of all the equipment connected. When not using a
PDU, each piece of equipment should be connected to a dedicated
branch circuit.
8.01
2.742.74 1.221.32
TOOL-LESS MOUNTING
#10-32 TAPPED HOLES
Figure A Figure B
Figure D
Figure C
1.64
3.003.00
6.01
7.67
.281"
Diameter
50%
Recommended
fill ratio
2.43
3.00 2.19 2.19
5.06
2.192.642.64
2.74 2.74 1.22
7.89
8.01
2.742.74 1.221.32
TOOL-LESS MOUNTING
#10-32 TAPPED HOLES
Figure A Figure B
Figure D
Figure C
1.64
3.003.00
6.01
7.67
.281"
Diameter
50%
Recommended
fill ratio
2.43
3.00 2.19 2.19
5.06
2.192.642.64
2.74 2.74 1.22
7.89
2.74
2.74
2.74
2.74
2.74
2.74
2.74
2.74
.281
3.00
9.00
10.65
13.57
13.89
1.64 2.00
13.50
42"D Bracket
48"D Bracket
PDU BRACKETS
STANDARD PDU BRACKETS TO MOUNT VERTICAL CABLE TROUGH
& PDUs
• Power strip brackets (one set in each rear corner) are standard and
ship with vertical space of 61.25" between brackets
• Brackets accept a wide range of Power Distribution Units (PDUs)
and Great Lakes vertical cable troughs (VCT) and vertical cable
bars (VCB)
• The size of the PDU will determine how many can be mounted on
the brackets; gures below show usable mounting space of brackets
• Brackets may need to be vertically adjusted to accept PDUs
2.74
2.74
2.74
2.74
2.74
2.74
2.74
2.74
.281
3.00
9.00
10.65
13.57
13.89
1.64 2.00
13.50
40"D Bracket
1.34
2.741.78
2.2003.000
6.0
1.37
3.15
2.200
.27
.24
1.34
2.741.78
2.2003.000
6.0
1.37
3.15
2.200
.27
.24

15
Brackets
are vertically
adjustable
along ange
A
DETAIL A
Part No. Description Compatible ES
VERTICAL CABLE TROUGH
VCT-91 76"H x 3"W x 2.5"D VCT 91"H ES sizes
VCT-91C Cover for VCT-91 91"H ES sizes
VCT-84 68"H x 3"W x 2.5"D VCT 84"H ES sizes
VCT-84C Cover for VCT-84 84"H ES sizes
VCT-79 62"H x 3"W x 2.5"D VCT 79"H ES sizes
VCT-79C Cover for VCT-79 79"H ES sizes
A
A
61.25" standard
spacing
#10-32 Screw
Keyhole pattern for
mounting PDUs

16
45°
15.377 REF
2.375 REF
1.241
Tinnerman clip or #10-32
keps nut. Install onto
corner post
#10-32 x 1/2" Machine screw
1/8" Ø
Alignment hole
#10-32 Thread
cutting screws
42" AND 48"D BRACKETS INSTALLATION IS IDENTICAL
SECTION B-B
45°
9.388 REF
2.386REF
61.250& 44.000
Mounting location
for VCT Mounting
location
for PDU
Mounting location
for VCT
42"D Bracket
Mounting location
for PDU
45°
15.377 REF
2.375 REF
1.241
48"D Bracket
Mounting location
for VCT
Mounting location
for VCT
PSBKES-A BRACKETS
• Standard PDU brackets in the 30/32"W cabinets can be
replaced with PSBKES-A
• Brackets allow PDUs to be mounted at an angle toward the rear of
the cabinet
• Brackets also accept VCTs

17
Detail C
M6 keps nut
M6 x 12mm
Philips pan
head screw
C
Rear face of rail
Rear face of rail
Front face of rail
(with RMU labels)
PSBKES-R-30 BRACKETS
• PDU Rail Brackets for 30/32"W cabinets allow the button
mount of a single PDU along the mounting rail
• The height of the PDU will determine where to position the brackets
along the rail

18
D
Detail D
ZR BRACKETS
• ZR1 and ZR2 brackets t in 30/32"W ES cabinets and allow for
“0” RMU mounting of 19" rack mount power strip units or other
1 or 2 RMU equipment (such as patch panels)
• Install the bracket onto the rail or post toward the side panel; ensure
you have 18.31" between the inner holes for 19" mounting
PSBKESF
• PBSKESF brackets t in the front
corner of 30/32"W ES cabinets
• Brackets allow for button mounting of
1 PDU
#10-32 screw
Front

19
CABLE MANAGEMENT FINGERS
• Fingers install on the front or rear face of any rail
• If installing on front rails, rails must be recessed 4.5" to accommodate
4"D ngers or recessed 7.5" to accommodate 7"D ngers
• It is recommended that each set of ngers is installed using 3 points
of attachment (with push-button rivets or screws and nuts)
Cable Management Fingers
F
Detail F
Detail G
FRONT-TO-REAR CABLE TROUGH
• HCM-D36 ts in 30/32"W cabinets and mounts to side panel ange
• Side panel must be removed rst
• Troughs cannot be installed once cabinets are ganged
G
Part No. Description Compatible ES
FINGERS
CM-47 4" X 7 RMU, single finger section All ES sizes
ESC-K12 4" x 7 RMU, set of 12 finger sections All ES sizes
CM-77 7" X 7 RMU, single finger section All ES sizes
ESC-K12-7 7" x 7 RMU, set of 12 finger sections All ES sizes
#10-32 x 3/4"
screw
Push-button rivet
#10-32 x 1/2"
screw

20
A
3.64
4.11
2.52
7.41
A
3.64
4.11
2.52
7.41
Detail H
Vertical Cable Manager
Front
Face of
Equipment
Mounting
Rails
Hinged Cover - Open
Top View
A
3.64
4.11
2.52
7.41
#10-32 x 3/4"
Phillips pan
head screw
Hinged
Cover
Vertical
Cable
Manager
Hinged
Cover -
Open
FMP Holes
#10-32
Keps
Nut
H
HINGED COVER VERTICAL CABLE MANAGER
• Hinged Vertical Cable Manager (VCMK) mounts to the Flexible
Mounting Prole (FMP) of mounting rails
• VCMK can be installed on left, right, front or rear rails
• If installed on front rails, rails must be recessed 9 1/8" for proper
hinge clearance
• Secure the VCMK with a minimum of 3 points of attachment
Part No. Description Compatible ES
VERTICAL CABLE MANAGER
VCM-91K 75.25"H x 3.78"W x 7.5"D VCM 30/32"W ES sizes
VCM-84K 70"H x 3.78"W x 7.5"D VCM 30/32"W ES sizes
VCM-79K 63"H x 3.78"W x 7.5"D VCM 30/32"W ES sizes
Hinged Cover Open
This manual suits for next models
36
Table of contents
Other Great Lakes Rack & Stand manuals

Great Lakes
Great Lakes VCMX Series User manual

Great Lakes
Great Lakes GLRR-1984 User manual

Great Lakes
Great Lakes CMR-45U16 User manual

Great Lakes
Great Lakes VRX User manual

Great Lakes
Great Lakes UL60950-1 User manual

Great Lakes
Great Lakes SR Series User manual

Great Lakes
Great Lakes WMCM Series User manual

Great Lakes
Great Lakes UL60950-1 User manual

Great Lakes
Great Lakes WR Series User manual

Great Lakes
Great Lakes WMCM Series User manual