14 Technical Information
Service Manual
6. Function and Control
1.Basic function of system
(1)Cooling mode
(1) Under this mode, fan and swing operates at setting status.
Temperature setting range is 16~30ºC.
(2) During malfunction of outdoor unit or the unit is stopped
because of protection, indoor unit keeps original operation status.
(2)Drying mode
(1) Under this mode, fan operates at low speed and swing
operates at setting status. Temperature setting range is 16~30ºC.
(2) During malfunction of outdoor unit or the unit is stopped
because of protection, indoor unit keeps original operation status.
(3) Protection status is same as that under cooling mode.
(4) Sleep function is not available for drying mode.
(3)Heating mode
(1) Under this mode, Temperature setting range is 16~30ºC.
(2) Working condition and process for heating mode:
When turn on the unit under heating mode, indoor unit enters into
cold air prevention status. When the unit is stopped or at OFF
status, and indoor unit has been started up just now, the unit
enters into residual heat-blowing status.
(4)Working method for AUTO mode:
1.Working condition and process for AUTO mode:
a.Under AUTO mode, standard heating Tpreset=20ºC and
standard cooling Tpreset=25ºC. The unit will switch mode
automatically according to ambient temperature.
2.Protection function
a. During cooling operation, protection function is same as that
under cooling mode.
b. During heating operation, protection function is same as that
under heating mode.
3. Display: Set temperature is the set value under each condition.
Ambient temperature is (Tamb.-Tcompensation) for heat pump
unit and Tamb. for cooling only unit.
4. If theres I feel function, Tcompensation is 0. Others are same
as above.
(5)Fan mode
Under this mode, indoor fan operates at set fan speed.
Compressor, outdoor fan, 4-way valve and electric heating tube
stop operation. Indoor fan can select to operate at high, medium,
low or auto fan speed. Temperature setting range is 16~30ºC.
2. Other control
(1) Buzzer
Upon energization or availably operating the unit or remote
controller, the buzzer will give out a beep.
(2) Auto fan
Heating mode: During auto heating mode or normal heating ode,
auto fan speed will adjust the fan speed automatically according
to ambient temperature and set temperature.
(3) Sleep
6.1 Brief Description of Models and Functions
After setting sleep function for a period of time, system will adjust
set temperature automatically.
(4) Timer function:
General timer and clock timer functions are compatible by
equipping remote controller with different functions.
(5) Memory function
memorize compensation temperature, off-peak energization value.
Memory content: mode, up&down swing, light, set temperature,
set fan speed, general timer (clock timer cant be memorized).
After power recovery, the unit will be turned on automatically
according to memory content.
(6)Refrigerant recovery function:
(1) Enter refrigerant recycling function
Within 5min after energizing (unit ON or OFF status is ok),
continuously press LIGHT button for 3 times within 3s to enter
refrigerant recycling mode; Fo is displayed and refrigerant
recycling function is started. At this moment, the maintenance
people closes liquid valve. After 5min, stick the thimble of
maintenance valve with a tool. If there is no refrigerant spraying
out, close the gas valve immediately and then turn off the unit to
remove the connection pipe.
(2) Exit refrigerant recycling function
After entering refrigerant recycling mode, when receive any
remote control signal or enter refrigerant recycling mode for
25min, the unit will exit refrigerant recycling mode automatically If
the unit is in standby mode before refrigerant recycling, it will be
still in standby mode after nishing refrigerant recycling; if the unit
is in ON status before refrigerant recycling, it will still run in original
operation mode.
(7)Off-peak energization function:
Adjust compressors minimum stop time. The original minimum
stop time is 180s and then we change to:
The time interval between two start-ups of compressor cant be
less than 180+T s(0≤T≤15). T is the variable of controller. Thats
to say the minimum stop time of compressor is 180s~195s. Read-
in T into memory chip when refurbish the memory chip each time.
After power recovery, compressor can only be started up after
180+T s at least.
(8) X-fan mode
When X-fan function is turned on, after turn off the unit, indoor fan
will still operate at low speed for 2min and then the complete unit
will be turned off. When x-fan function is turned off, after turn off
the unit, the complete unit will be turned off directly.
(9) 8º heating function
Under heating mode, you can set 8º heating function by remote
controller. The system will operate at 8ºset temperature.
(10) Turbo fan control function
Set turbo function under cooling or heating mode to enter into
turbo fan speed. Press fan speed button to cancel turbo wind.
No turbo function under auto, dry or fan mode.