USAGE
INSTALLATION INSTRUCTIONS
The hand-dryer is intended to be a ixed to a vertical wall in industrial and commercial areas and to be
used exclusively or drying hands. The electrician should determine the suitability o area to it.
Always ensure that the installation con orms to the current edition o the wiring regulations, BS 7671 (UK) or
the appropriate standards in your country.
Ensure that the unit is separately used with a 5A use, we recommend connecting to a RCD double pole spur
unit (similar to a PowerBreaker H92 model).
Care should be taken that single insulated conductors cannot come into contact with the mounting
sur ace.
SAFETY PRECAUTIONS
1. Read all the instructions care ully be ore using the appliance.
2. Remove the packages and ensure that the appliance is undamaged.
In case o doubt do not use the appliance and contact your supplier.
3. Do not install the automatic hand dryer on wooden or plastic walls.
4. Do not install the appliance within range o people using baths or showers.
5. Be ore installing the unit, check that the electrical voltage o your main supply corresponds to the voltage
marked on the rating label o the appliance.
6. Be ore installing the appliance, check that there are no obstructions within 50cm o the sensor.
7. Be ore maintenance or repair, make sure that the unit is disconnected.
8. Do not insert any objects into the appliance.
9. Prevent water rom getting into the housing o the appliance during operation or in storage.
Hazard o electric shock, always store in dry area with no moisture.
10. Do not use outdoors.
11. The appliance is not intended or use by young children or in irm persons without supervision.
Description of parts:-
1. Cover
2. Air Outlet
3. Infrared-sensor
4. Power Cable
3
4
2
1
1. Remove all packaging materials care ully.
2. Check or service pipes and cables in the wall be ore drilling.
3. Drill our holes with a diameter o 6mm where the unit is to be installed, according to the dimension
sketch as shown in Dia.1, and insert wall plugs.
4. A distance o at least 200mm to the next wall (or other solid objects) must be kept or servicing to both
sides.
5. A distance o at least 800mm below the hand dryer must be kept clear rom any radiators, wash basins
etc located below the unit.
6. Follow the suggested assembly heights. The assembly height is measured rom the upper assembly
holes to the loor and is determined as ollowing:-
a) 1.5 metres above loor or normal use.
b) 800mm distance above shelves, sinks or radiators.
7. Unscrew both the screws on the ront side o the hand dryer and detach the cover (1) by tilting it
upwards (Dia.3).
AFTER INSTALLATION OR SERVICING, UNITS MUST BE CHECKED AND ONLY LEFT
WHEN ELECTRICALLY AND MECHANICALLY SAFE.
The hand dryer must not be installed within range o people using baths and/or showers.
Dia.2
212mm
157mm
Dia.1
min.
800mm
min.
200mm
8. Fix the hand dryer with the 4enclosed screws to the
holes. It can be help ul to use lat washers or assembly,
to achieve a clean and secured assembly. Please keep in
mind that the assembly area must be even and clean.
9. Using the miniature slide switch on the ront o the an
housing, set the switch to ‘Cool’ (500W) or ‘Heat’
(1000W).
10. Replace the cover by positioning the cover (1) at irst
below the air outlet (2). Now place the cover over the
hand dryer and push or draw the upper edge o the cover
with both the retaining collars as ar as the retaining
base, until the cover latches.
11. The hand dryer should be connected to the mains supply
via a used spur unit. Dia.3