faceplate.
To Prime Auger: Restart the unit five (5) minutes into its startup or by putting a small hand full of pellets into the burnpot.
To Operate Stove: MANUAL MODE: When a fire has been established the stove settings are adjustable. / HIGH/LOW MODE: (Requires a thermostat) When the
thermostat calls for heat the stove settings are adjustable. When the thermostat contacts open, the HEAT LEVEL and Fans will drop down to the LOW setting
until the thermostat contacts close again. / AUTO/OFF MODE: (Requires a thermostat) When the thermostat contacts close, the unit will light automatically.
Once up to temperature the stove settings are adjustable. When the thermostat contacts open, the stove will drop down to the LOW settings for 30 minutes. If
within the 30 min the thermostat contacts close, the HEAT LEVEL will return to previous MANUAL setting or if the thermostat contacts remain open the stove
begin its shutdown routine.
To Turn Off Stove: MANUAL and HI / LOW mode: Press the ON / OFF button
AUTO / OFF mode: Turn the thermostat down or off
The unit can be installed on a hard,
stable non-combustible surface.
L'appareil peut être installé sur une
surface non-combustible dure et stable.
Certified for use in Canada & USA
Certifié pour installation au
Canada et aux Etats-Unis.
Listed Room Heater, Pelletized Fuel Type (Appareil de chauffage à granules certifié)
Suitable For Mobile Home Installation (conçu pour être installédans une maison mobile) Tested to
(Testée selon):
UL 14 82 -19 98 / ULC S627-00 / ASTM 1509-95 / ULC S628-M93
US Environmental Protection Agency, certified to comply July 1, 1990, particulate emission
standards. (certifié conforme aux normes de l'US Environnemental Protection Agence du 1er juillet
1990, concernant les particules d'émission.)
This pellet appliance has been tested and listed for use in manufactured homes in accordance with Oregon
Administration Rules 814-23-900 through 814-23-909. Install and use only in accordance with the Manufacture’s
installation and operating instructions. Contact local building or fire officials about restrictions and installation inspection in
your area. Do not connect this unit to a chimney flue serving another appliance. See local building codes and
manufacturers instructions for precautions required for passing a chimney through a combustible wall or ceiling. Electrical
rating: 120 volts, 60 hz, 4.3 Amps. Route cord away from the heater.
Cet appareil a été testé et certifié pour être utilisédans les maisons mobiles en accord avec les "Règles Administratives
de l'Oregon 814-23-900 à 814-23-909". Installez et utilisez cet appareil seulement selon les consignes d'installation et
d'utilisation du fabricant. Contactez les autorités locales de votre région concernant les restrictions et les inspections
d'installation. Consultez les codes locaux dubâtiment et les instructions du fabricant concernant les précautions à
prendre lorsque une cheminée doit être installée àtravers un mur ou un plafond combustible. Alimentation électrique :
120 Volts, 60 Hz, 4.1 Amps. Placez le câble électrique loin de l'appareil.
For Use With Only Pelletized Wood fuels. Operate only with viewing door and ash removal door closed. Only replace
glass with ceramic glass. Components required for installation: a 3 inch (75 mm) or 4inch (100 mm) listed PL vent,
complete with components. Insert and Hearth mount installations; a listed single wall chimney liner may be used. Inspect
and clean Exhaust Venting system frequently.
Utilisation avec les combustibles sous forme de bois en granules uniquement. Utiliser seulement lorsque les portes avant
et la porte du réceptacle de cendre sont fermées. Si une ou des vitres doivent être remplacées, utilisez seulement du
verre céramique. Pièces requises pour l'installation du poêle : évacuation PL certifiéede 3 po (75mm)ou4 po (100mm)
avec ses composants. Installations du montage de l'encastrable et du foyer ; un conduit de cheminée à paroi simple
homologué peut être utilisé. Inspectez et nettoyez régulièrement le système d'évacuation.
Input Rating (débit calorifique): 12,000 to 45,000 BTU/Hr (3.5 to 13.2 kWh)
334
2009 2010 2011
CAUTION:
Hot while operating. Do not
touch, severe burns may
result. Keep children, clothing,
furniture, gasoline or other
flammable vapors away
.
ATTENTION:
Appareil chaud quand il fonctionne. Ne
pas toucher. Peut causer de graves
brûlures. Tenir hors de portée des enfants,
des vêtements, des meubles, de tout
carburant ou autre gaz inflammable.
DO NOT REMOVE THIS LABEL /
NE PAS RETIRER CETTE ÉTIQUETTE
See installation and operating instructions accompanying appliance. /
Consultez le manuel d’installation et d’utilisation de l'appareil
.
A Sidewall to Unit (De la paroi latérale à l'appareil)
8” (203 mm)
B� Top of unit to an unshielded 8” (203 mm) mantle
�(Du haut de l'appareil à un manteau de cheminée non blindé) 8” (203 mm)
C Unit to top facing (protruding ¾” [19 mm])
(
De l'uappareil au sommet du parement)
8” (203 mm)
D Unit to side facing (protruding ¾” [19 mm])
(
De l'appareil au parement latéral)
8” (203 mm)
E� From door opening of unit to edge of floor protection
�(De l'ouverture de la porte à l'avant de protection de plancher) 6” (152 mm)
F From side of unit to edge of floor protection (De l'ouverture
de la porte à l'avant de la protection de plancher) 6” (152 mm)
Combustible floors must be protected by a non-combustible material. - See Owners Manual.
Le plancher combustible doit être protégé par un matériel non combustible. - Consultez le
manual.
INSTALLED AS A FIREPLACE INSERT STOVE MODEL (GFI55) / À
INSTALLERCOMME UN POÊLE ENCASTRABLE (GFI55).
Minimum clearances to combustible materials./ Dégagements minimaux aux
matériaux combustibles :
A Sidewall to Unit (De la paroi latérale à l'appareil)
6” (152 mm)
B Backwall to Unit (De la paroi du fond à l'appareil) 3” (76 mm)
C� Corner to Unit (Du coin à l'appareil)
2” (51 mm)
D Wall to vent (Du mur au système d'évacuation) 3” (76 mm)
E� From door opening of unit to edge of floor protection
�6” (152 mm)
�
�
�
�
�
(De l'ouverture de la porte au devant de protection de
plancher) NOTE: A combustible floor must be protected by a
non-combustible material - Width 27" (686mm) by depth 34"
(864mm). (Un plancher combustible doit être protégépar un
matériau non combustible. 27 po de large (686 mm) x 34 po
de profond (864 mm).)
�Minimum Alcove Width (Largeur minimale de l'alcôve) 36” (914 mm)
�Minimum Alcove Height (Hauteur minimale de l'alcôve) 48” (1219 mm)
�Maximum Alcove Depth (Profondeur maximale de l'alcôve) 30” (762 mm)
INSTALLED AS A FREESTANDING STOVE MODEL (GF55) / À INSTALLERCOMME
UN POÊLE AUTOPORTANT, QU’IL SOIT ENCASTRÉ, SUR PIED OU DANS UNE
MAISON MOBILE.
Minimum clearances to combustible materials./ Dégagements minimaux
aux matériaux combustibles :
Serial No. / No. De Serié:
Greenfire GF55 (Stove) GFI55 (Insert)
Model / Modèle:
15956
B
A
D
C
Adjacent wall
FE
Floor Protection
A
B
C
E
Backwall
Sidewall
D
Pour démarrer le poêle: Appuyer sur le bouton "ON/OFF". Si le Auger nécessite d'être amorcé, appuyer sur le bouton manuel d'alimentation du Auger jusqu'à ce que les granules se déversent dans le pot de combustion.
Pour faire fonctionner le poêle : MODE MANUEL : Lorsque le feu est bien établi, les réglages peuvent être ajustés. / MODE "HIGH/LOW" : (Nécessite un thermostat) Lorsque le thermostat requière de la chaleur, les réglages peuvent être ajustés. Lorsque les contacts du
thermostat ouvrent, le réglage du niveau de chaleur et les ventilateurs s'ajusteront au réglage " bas " jusqu'à ce que les contacts du thermostat se referment. / MODE "AUTO/OFF" : (Nécessite un thermostat) Lorsque les contacts du thermostat ferment, le poêle s'allumera
automatiquement. Lorsque la température adéquate est atteinte, les réglages peuvent être ajustés. Lorsque les contacts du thermostat ouvrent, le poêle s'ajustera aux réglages "LOW" pendant 30 minutes. Si les contacts du thermostat sont fermés pendant ces 30
minutes, le réglage de niveau de chaleur retournera sur "MANUEL" ou si les contacts du thermostat restent ouverts, le poêle entamera le processus d'arrêt.
DATE OF MANUFACTURE /
DATE DE FABRICATION :
Pour éteindre le poêle : MODE MANUEL ET " HIGH/LOW " : Appuyer sur le bouton "ON/OFF".
Manufactured in Canada for /
Fabriqué dans le Canada pour:
FPI Fireplace Products International Ltd.
Delta, BC, Canada
Model BIH Only Minimum Clearance to Combustible Materials / Espace de
dégagement requis pour le modèle BIH:
G
B
H
BIH Model
E
FPI or BIH
Models
G� From
Sides and rear walls to standoffs
�(
Des parois latérales et arrière aux espaceurs
) 0” (0 mm)
H
Recess depth
(
Profondeur de la cavité
) 11” (280 mm)
FS Model
MODE "AUTO / OFF" : Régler le thermostat à la baisse ou l'éteindre.
GF55-081a
J F M A M J J A S O N D