Greennet TiNet S8600-04 User manual

TiNet S8600-04 GPON OLT
User Manual
Hardware Configuration Manual
1. Product Description
2. Specifications and Characteristics
3. Preparation Before Installation
4. Installation
5. Startup and Configuration
6. Software Upgrade
7. Troubleshooting
8. Optional Interface Modules
9. Appendix RJ-45 Connector

Shenzhen New Greennet Technologies Co., Ltd. Contents
I
Contents
Chapter 1 Product Description.......................................................................................................... 1-1
1.1 Basic Information.......................................................................................................................1-1
1.2 Typical Applications...................................................................................................................1-1
Chapter 2 Specifications and Characteristics............................................................................... 2-1
2.1 Appearance................................................................................................................................ 2-1
2.2 Front Panel.................................................................................................................................2-1
2.2.1 Front Panel......................................................................................................................2-1
2.2.2 Attributes of GPON OLT SFP Ports............................................................................ 2-4
2.3 Rear Panel of TiNet S8600-04 GPON OLT.......................................................................... 2-6
2.3.1 Rear Panel...................................................................................................................... 2-6
2.3.2 Optional Power Modules for Power Module Slots....................................................2-6
2.4 System Characteristics.............................................................................................................2-7
Chapter 3 Preparation Before Installation...................................................................................... 3-1
3.1 Safety Precautions....................................................................................................................3-1
3.2 Installation Site Inspection.......................................................................................................3-1
3.2.1 Temperature/Humidity................................................................................................... 3-2
3.2.2 Cleanliness......................................................................................................................3-2
3.2.3 Immunity to Interference...............................................................................................3-3
3.3 Installation Tools and Devices.................................................................................................3-4
Chapter 4 Installation............................................................................................................................4-1
4.1 Mechanical Installation............................................................................................................. 4-1
4.1.1 Installing the Device in a Cabinet................................................................................4-1
4.1.2 Installing the Device onto a Workbench.................................................................... 4-2
4.2 Connection of Power Cables and Ground Cables...............................................................4-3

Shenzhen New Greennet Technologies Co., Ltd. Contents
II
4.2.1 AC Power Supply and Installation...............................................................................4-3
4.2.2 DC Power Supply Installation...................................................................................... 4-3
4.2.3 Installing the Ground Cable......................................................................................... 4-4
4.3 Connecting the Console Cable............................................................................................... 4-4
4.3.1 Installing the Console Cable........................................................................................ 4-4
4.3.2 Connecting the Console Cable....................................................................................4-5
4.4 Check after Installation.............................................................................................................4-5
Chapter 5 Start and Configuration....................................................................................................5-1
5.1 Local Terminal Configuration...................................................................................................5-1
5.1.1 Creating a Configuration Environment.......................................................................5-1
5.1.2 Connecting the Console Cable....................................................................................5-1
5.1.3 Setting Terminal Parameters........................................................................................5-1
5.2 Powering On the OLT............................................................................................................... 5-7
5.2.1 Checking the OLT Before Power-on...........................................................................5-7
5.2.2 Powering On the Device...............................................................................................5-8
Chapter 6 Software Upgrade.............................................................................................................. 6-1
Chapter 7 Troubleshooting................................................................................................................. 7-1
7.1 Power Supply System Failure.................................................................................................7-1
7.2 Configuration System Failure..................................................................................................7-1
7.2.1 No Terminal Display.......................................................................................................7-1
7.2.2 Garbled Characters....................................................................................................... 7-2
Chapter 8 Appendix RJ-45 Connector............................................................................................. 8-3
8.1 RJ-45 Connector....................................................................................................................... 8-3
8.2 Cable making............................................................................................................................. 8-5

Shenzhen New Greennet Technologies Co., Ltd.
1
Chapter 1 Product Description
1.1 Basic Information
TiNet S8600-04 is New Greennet's self-developed frame-type GPON OLT,
boasting high performance, high port density, ease of installation, good
expandability, and low cost. The OLT provides one control board slot and five
service board slots and allows you to mix Gigabit uplink subboards and
10-Gigabit subboards. TiNet S8600-04 enables access to a variety of
IP/Ethernet services in point-to-multipoint networks, including emerging IP
broadband services such as IPTV/VOD, VoIP, and videophone and enterprise
services such as VPN and video conferencing. Besides providing Gigabit fiber
optic transmission capacity, the OLT also reduces service deployment and
management costs for its cost-effectiveness and good expandability.
1.2 Typical Applications
TiNet S8600-04 GPON OLT employs the modular design, and can be
deployed on an enterprise network or used for broadband access.

Shenzhen New Greennet Technologies Co., Ltd.
2

Shenzhen New Greennet Technologies Co., Ltd.
1
Chapter 2 Specifications and Characteristics
2.1 Appearance
Figure 2-1 TiNet S8600-04 GPON OLT appearance
2.2 Front Panel
2.2.1 Front Panel
Figure 2-2 shows the layout of the front panel of the TiNet S8600-04 GPON
OLT, including two control card slots and four line card slots:
Figure 2-2 Front panel of the TiNet S8600-04 OLT
Slot 0 – for active control card NG01MSUA0
Slot 1 - houses standby control card NG01MSUA0

Shenzhen New Greennet Technologies Co., Ltd.
2
Slots 2-5 - house four NG01PG08MAs (OLT service board) or
NG01GT24MAs with Gigabit uplink electrical ports
The panel of a control board of the TiNet S8600-04 GPON OLT is as shown
below:
The panel provides several LED indicators, a USB backup port, an RS232
serial console port (marked CONSOLE), a port for management (marked
AUX), and a port for remote login.
Front panel LED indicators are explained as given in Table 2-1:
Table 2-1 Meanings of LED indicators on the front panel of a control board of TiNet
S8600-04 GPON OLT
Indicator
Sign on
the Front
Panel
Status Meaning
System status
indicators
RUN
Flashing The OLT is running properly.
Always
ON or OFF
The OLT malfunctions.
FAU
Always
ON
Always
OFF
ACT
Always On The current control board is running.
Always
OFF Backup main control panel status
PWR On The power supply is normal.
Off A power supply failure occurs.

Shenzhen New Greennet Technologies Co., Ltd.
3
Indicator
Sign on
the Front
Panel
Status Meaning
PWR in-position PRES
Always on The power module can be detected.
Always
OFF
The power module slot is vacant or the
power module is faulty.
OK
Always on The power module is operating normally.
Always
OFF
The power module slot is vacant or the
power module is faulty.
SLOT status
indicators
PRES
Always on The slot has a line board.
Always
OFF The slot does not have a line board.
ACT
Always on The slot is operating normally.
Always
OFF
The slot is faulty or does not have a
board.
FAU
Always on The slot is faulty.
Always
OFF The slot is operating normally.
The front panel layout of a line board of TiNet S8600-04 GPON OLT is as
shown below:
The panel provides eight 1000 Base-x SFP uplink ports GE1 ~ GE8, eight
GPON OLT SFP ports GP1 ~ GP8, one RS232 Console port, one port for
commissioning AUX. The LED indicators are explained as given in Table 2-1:

Shenzhen New Greennet Technologies Co., Ltd.
4
Table 2-2 Indicators on the front panel of a line board of TiNet S8600-04 GPON OLT
Indicator
Sign on the
Front
Panel
Status Meaning
Power
indicator PWR
On
The board is operating under normal voltage.
Off The board is operating under abnormal
voltage.
Single panel
running
indicator
RUN
Blinking The CPU of the board is normal.
Off The CPU of the board is abnormal.
Indicator for
the port for
commissioning
AUX
Off
The AUX port is connected improperly or
unconnected.
On The AUX port is connected properly.
Flashing The AUX port is connected properly and is
transmitting data.
GE status
indicator GE
Off
The GE port is connected improperly or
unconnected.
On The GE port is connected properly.
Flashing The AUX port is connected properly and is
transmitting data.
GPON status
indicator GP
Off No ONU is registered with the PON port.
On
There is at least one ONU registered with the
PON port.
Flashing The PON port has registered ONUs and is
transmitting data.
2.2.2 Attributes of GPON OLT SFP Ports
The front panel of TiNet S8600-04 OLT provides up to 32 GPON OLT SFP
ports and 24 GE Gigabit Ethernet ports. SFP modules are hot swappable and
can be configured flexibly, which improves networking flexibility. Users may
select the desired SFP modules according to Table 2-4.

Shenzhen New Greennet Technologies Co., Ltd.
5
Table 2-3 Optional modules for GPON OLT SFP interface
SFP Module Center
Wavelength
Connector
of the
Optical
Cable
Fiber
Specifications
Maximum
Transmission
Distance of
Optical Fibers
SFP-GPON-LH10
1310 nm in
receiving, 1550
nm in sending LC
Single-mode
fiber 10km
SFP-GPON-LH20
1310 nm in
receiving, 1550
nm in sending
Single-mode
fiber 20km
Table 2-4 Optional modules for GE Gigabit Ethernet SFP interface
SFP Module Center
Wavelength
Connector
of the
Optical
Cable
Fiber
Specifications
Maximum
Transmission
Distance of
Optical Fibers
SFP-GE-SX-MM850 850 nm
LC
Multimode
fiber 550m
SFP-GE-SM1310-LH10
1310 nm Single-mode
fiber
10km
SFP-GE-SM1310-LH20 20km
SFP-GE-SM1310-LH40 40km
SFP-GE-SM1550-LH40 1550 nm 40km
SFP-GE-SM1550-LH60 60km
Gigabit SFP modules may be updated from time to time. Consult the
marketing staff of New Greennet for latest module information.

Shenzhen New Greennet Technologies Co., Ltd.
6
2.3 Rear Panel of TiNet S8600-04 GPON OLT
2.3.1 Rear Panel
Figure 2-3 shows the rear panel of TiNet S8600-04 OLT, on which two power
module slots and one grounding post are available.
Figure 2-3 Rear panel of TiNet S8600-04 GPON OLT
1 - 2 power input options;
2 – Grounding post;
TiNet S8600-04 GPON OLT supports both AC and DC power
supply.
2.3.2 Optional Power Modules for Power Module Slots
The rear panel of TiNet S8600-04 GPON OLT has two power options. The
power input can be either of the following:
POWER-AC750: 750W AC power supply module (176~264V/50~60Hz)
POWER-DC750: 750W DC power module (-36V~-72V DC input)

Shenzhen New Greennet Technologies Co., Ltd.
7
2.4 System Characteristics
Table 2-8 System characteristics of TiNet S8600-04 GPON OLT
Item TiNet S8600-04 GPON OLT
Processor CAVIUM
BOOTROM 512 KB
SDRAM 2 GB
FLASH 8 MB
Dimensions (W ×
H × D) 442 mm × 175 mm × 420 mm
Weight <40 kg
Input Voltage AC: 176V~264V 47/63Hz
DC: -36V ~ -72V
Maximum Power < 750W
Port 32 GPON OLT SFP ports
24 GE SFP ports
Switching mode Store-and-forward
Switching
Capacity 960Gbps
Standards
Compliant
IEEE 802.3ah GPON
IEEE802.3 (10Base-T)
IEEE802.3u (100Base-TX)
IEEE802.3z (1000BASE-X)
IEEE802.3ab (1000Base-T)
IEEE802.1Q (VLAN)
IEEEE802.1d (STP)
IEEEE802.1W (RSTP)
IEEEE802.1S (MSTP)
IEEE802.1p (COS)
IEEE802.1x (Port Control)
IEEE802.3x (Flow Control)
IEEE802.3ad (LACP)
Each OLT interface supports up to 64 ONUs;

Shenzhen New Greennet Technologies Co., Ltd.
8
Item TiNet S8600-04 GPON OLT
The transmission distance of each OLT is up to 20Km
L2 functions VLAN, QinQ, link aggregation, Broadcast storm control
Supports up to 4096 VLANs;
Multicast
L3 multicast: IGMPv1/v2/v3, PIM-DM, PIM-SM, support for 1K L3
multicast routing tables
L2 Multicast: IGMPv2 in RFC 2236, IGMPv3 in RFC 3376, IGMP
Filter, IGMP Fast leave, controllable multicast, inter-VLAN
multicast replication, support for 1K L2 multicast groups
ACL/QOS
Supports standard and extended ACLs. A maximum of 2K to 6K
ACL rules can be effective simultaneously.
Supports Time-Range-based ACL policy
Provides flow classification and flow definition based on such IP
packet header information as source/destination MAC address,
VLAN, 802.1p, ToS, DiffServ, source/destination IP (IPv4/IPv6)
address, TCP/UDP port number, and protocol type. The system
can identify a maximum of 2 K service flows concurrently.
Supports L2 ~ L7 and packet filtering 80 bytes further in IP packet
header.
Supports rate limitation by port or flow on packets receiving and
sending, and provides ordinary traffic policing and two-rate
three-color traffic policing on flows.
Supports priority marking by port or flow, and provides the priority
Remark function based on 802.1P and DSCP.
Supports Committed Access Rate (CAR), Traffic shaping and
traffic statistics.
Supports packet mirroring and packet redirection by port or flow
Supports advanced queue scheduling based on ports and flows.
Each port or flow can be configured with at most eight priority
queues, where queue scheduling algorithms such as SP, WRR,
and SP + WRR are applied.
Supports congestion avoidance mechanisms such as Tail-Drop
and WRED.

Shenzhen New Greennet Technologies Co., Ltd.
9
Item TiNet S8600-04 GPON OLT
Security Features
Supports automatic display of the source MAC address of the host
that launches an attack, and automatic binding of IP and MAC
addresses, to prevent the ARP tables of normal users from being
tampered in ARP spoofing and gateway IP addresses from being
forged in ARP attacks.
The ARP traffic of each user can be limited and users with
abnormal ARP traffic may be automatically blacklisted.
Supports effective protection against various DOS attacks (such
as ARP attack, Synflood attack, Smurf attack, ICMP attack), ARP
monitoring, network worms and Blaster virus attack.
Supports port trust functions to detect illegitimate DHCP servers
and Radius servers.
Supports Unicast Reverse Path check (URPF), which can
effectively prevent IP address forgery and attacks.
Supports ACL-based flow filtering.
Supports IEEE 802.1x and AAA/Radius authentication.
Enables users to bind IP addresses, VLAN IDs, MAC addresses
and port numbers.
Supports DHCP Option82, and PPPoE + so that the physical
location information of users can be uploaded.
Supports plaintext authentication of OSPF, RIPv2 and BGPv4
packets and MD5 ciphertext authentication.
Supports IP Source Guard, guaranteeing DHCP service security.
Supports RFC3176 sFlow traffic analysis, achieving protocol or
address-based traffic monitoring and statistics.
Supports broadcast packet suppression.
Supports data logging and RFC 3164 BSD syslog Protocol.
Supports SSHv2 Secure Shell.
Supports login through Telnet of Security IP and password-based
login.
Supports hierarchical user protection to prevent intrusion from
unauthorized users, and grants different levels of users different
configuration rights.

Shenzhen New Greennet Technologies Co., Ltd.
10
Item TiNet S8600-04 GPON OLT
Reliability
Supports HSRP and VRRP.
Supports BFD, FlexLink L2 link backup, LACP, enhanced STP
(healing time is less than 1s), GERP (healing time is less than 50
ms) and other link fault recovery and redundancy mechanisms.
Both host programs and configuration files are able to recover from
faults.
Boards are hot swappable.
Supports 1 +1 power supply hot backup.
Operating
Temperature 0oC~45oC
Operating
Humidity 10%~90%

Shenzhen New Greennet Technologies Co., Ltd.
1
Chapter 3 Preparation Before Installation
3.1 Safety Precautions
To avoid device damage and bodily injury caused by improper use, observe
the following precautions:
Disconnect the device from a power source before cleaning it. Do not
clean it with a damp cloth or liquids.
Do not put the device near water or in damp places to prevent water and
moisture from entering the device chassis.
Do not place the device in a case or on a desk which is in unstable state
to prevent the device from dropping.
Maintain good ventilation and keep the air ducts of the device unblocked.
Be sure that the operating voltage of the device agrees with what is
marked on the device; otherwise, the device may operate improperly.
To avoid electric shock, do not open the shell without permission even if
the device is disconnected from a power supply.
3.2 Installation Site Inspection
The following conditions must be guaranteed regardless of where the TiNet
S8600-04 GPON device is installed (inside a cabinet or on a workbench):
A space is reserved at the air inlet and outlet of the device so that heat
dissipation of the device chassis can be expedited.
The cabinet or workbench is fitted out with a sound ventilation system.
The cabinet or workbench is secure enough to support the weight of the
device.

Shenzhen New Greennet Technologies Co., Ltd.
2
The cabinet or workbench is correctly grounded.
To ensure normal operation of the device and prolong its service life, the
installation site should also meet the following requirements.
3.2.1 Temperature/Humidity
Constant temperature and humidity should be maintained inside the machine
room. If the machine room is kept humid inside in a long time, symptoms,
such as poor insulation and even electric leakage of insulating materials,
mechanical property degradation, and corrosion of metal parts, may occur.
Low relative humidity would cause fastening screws to loosen due to
shrinkage of insulation washers. Furthermore, in a dry climate, it is easy to
produce static electricity, endangering the CMOS circuit on the device. High
temperature greatly reduces device reliability and even shortens its service
life in a long term. Long-term exposure to a high temperature will accelerate
the aging of insulating materials.
3.2.2 Cleanliness
Dust is a hazard to safe operation of the device. The dust accumulated on the
chassis can cause electrostatic adsorption, leading to poor contact of metal
connectors or contact points. The electrostatic adsorption is more likely to
take place especially in a low-humidity indoor environment, which will affect
the device’s service life and cause communication failures as well.
Table 3-1 describes the requirements for dust concentration and diameter
inside the machine room.
Table 3-1 Requirements for dust concentration inside the machine room
Maximum Diameter (μm) 0.5 1 3 5
Maximum Concentration
(Number of Particles Per
Cubic Meter)
1.4×1077×1052.4×1051.3×105

Shenzhen New Greennet Technologies Co., Ltd.
3
Besides dust, the machine room housing device is also sensitive to salts,
acids, and sulfides contained in the air. These harmful gases can accelerate
the corrosion of metal parts and aging of certain parts. The machine room
should be free of harmful gases such as SO2, H2S, NO2, NH3, Cl2. See Table
3-2 for specific limits.
Table 3-2 Limits of harmful gases in the machine room
Gas Average Concentration
(mg/m3)Maximum Concentration (mg/m3)
SO2 0.2 1.5
H2S 0 0.03
NO2 0.04 0.15
NH3 0.05 0.15
Cl2 0 0.3
3.2.3 Immunity to Interference
The device in use may be affected by external interferences which impact the
device through capacitive coupling, inductive coupling, electromagnetic
radiation, and common impedance (including the grounding system) coupling
and conductors (power cables, signal cables, output cables, etc.) in a
conductive way. To this end, it should be noted:
The TN AC power supply system is adopted, and AC power socket
should employ the single-phase three-wire power outlet with protective
earth (PE) to enable the filter circuit to effectively filter the grid
disturbance.
The device should be kept away from high-power radio transmitters,
radar stations, and high-frequency devices.
Electromagnetic shielding measures, such as the use of shielded
interface cables, should be taken when necessary.

Shenzhen New Greennet Technologies Co., Ltd.
4
3.3 Installation Tools and Devices
Required tools
Slot type screwdriver
Phillips screwdriver
Anti-ESD wrist strap
Cables
Power cable
Console cable
Ethernet cable
Required device
Terminal for configuration (or a PC)
Installation tools are not delivered with TiNet S8600-04 GPON OLT
but prepared by users themselves.

Shenzhen New Greennet Technologies Co., Ltd.
1
Chapter 4 Installation
One mounting screw of the device chassis has a New Greennet’s
tamper-evident strip. Agents will check whether this strip is intact before
starting to maintain the device. Therefore, users shall contact the local
agent for permission before uncovering the device chassis; otherwise,
users shall be responsible if the device cannot be maintained.
4.1 Mechanical Installation
4.1.1 Installing the Device in a Cabinet
TiNet S8600-04 GPON OLT can be installed in standard cabinet through the
following operations:
Step 1: Check the cabinet grounding and stability. Screw the angle bar on the
two sides of device front or rear panel;
Step 2: Place the device on a tray in the cabinet. Push the device along the
cabinet guide rail to an appropriate location.
Step 3: Screw angle bars to the fixed guide rails on both sides of the cabinet,
and ensure that the device is securely fixed in the cabinet.
Table of contents
Popular Switch manuals by other brands

Smart Technologies
Smart Technologies X-Port 20 Switch (XP20-2000i-B) installation guide

Tripp Lite
Tripp Lite B119-303-R owner's manual

Black Box
Black Box LGB5510A Installation and getting started guide

Planet
Planet IGSW-24040T user manual

SMART-AVI
SMART-AVI HDN-4 Quad quick start guide

Tripp Lite
Tripp Lite B007-008 Specifications