manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Grohe
  6. •
  7. Kitchen & Bath Fixture
  8. •
  9. Grohe ARDEN 20 388 User manual

Grohe ARDEN 20 388 User manual

D
.....1
NL
.....6
PL
.....11
P
.....16
BG
.....21
CN
.....26
GB
.....2
S
.....7
UAE
.....12
TR
.....17
EST
.....22
UA
.....27
F
.....3
DK
.....8
GR
.....13
SK
.....18
LV
.....23
RUS
.....28
E
.....4
N
.....9
CZ
.....14
SLO
.....19
LT
.....24
I
.....5
FIN
...10
H
.....15
HR
.....20
RO
.....25
DESIGN + ENGINEERING
GROHE GERMANY
www.grohe.com
20 388
ARDEN
99.0012.031/ÄM 223380/08.12
English .....4
Français .....6
Español .....8
I
S.v.p remettre cette instruction à l'utilisateur de la robinetterie!
Entregue estas instrucciones al usario final de la grifería!
Please pass these instructions on to the end user of the fitting!
1
II 2
3
1
27mm
2
4
A
A1
48 202
HOT
48 203
COLD
27mm
3
4
English
Application
Operation is possible in conjunction with:
- Pressurized storage heaters
- Thermally controlled instantaneous heaters
- Hydraulically controlled instantaneous heaters
Operation with low-pressure storage heaters
(displacement water heaters) is not possible.
Technical data
•Max. flow 5.7 L/min or 1.5 gpm/60 psi
•Flow pressure
- min. 7.25 psi
- recommended 14.5 - 72.5 psi
- greater than 72.5 psi, fit with pressure reducing valves
•Max. operating pressure 145 psi
•Test pressure 232 psi
•Temperature
- max. (hot water inlet) 176 °F
•Water connection cold - Right hand
hot - Left hand
Note
Major pressure differences between cold and hot water supply
should be avoided.
Installation, see Fig. [1].
See dimensional drawing on page 1.
The cold water supply should be connected on the right side
valve and the hot water supply to the left valve.
Flush piping system prior and after installation of faucet
thoroughly!
Mount lift rod and pop-up drain, see Fig. [2] and Fig. [3].
Ensure that flange of pop-up drain is sealed.
Open cold and hot water supply and check connections
for leakage.
Maintenance
Inspect and clean all parts, replace as necessary and grease
with special grease.
Shut off cold and hot water supply.
I. Ceramic cartridge, see Fig [4].
Change complete ceramic cartridge (A) or O-ring (A1).
Observe the different replacement part numbers of the
cartridges.
II. Flow control, see page 2.
Unscrew and clean flow control (48 159).
Assemble in reverse order.
Replacement parts, see page 2 ( * = special accessories).
Care
Instructions for care of this faucet will be found in the Limited
Warranty supplement.
5
2
1
27mm
3
4
A
A1
48 202
HOT
48 203
COLD
27mm
6
Français
Domaine d'application
Le service est possible en combinaison avec:
- Des chauffe-eau à accumulateur sous pression
- Des chauffe-eau instantanés à commande thermique
- Des chauffe-eau instantanés à commande hydraulique
Un service avec des systèmes d'eau chaude à écoulement
libre n'est pas possible.
Caractéristiques techniques
•Débit maxi. 5,7 l/min ou 1,5 g/min / 4,1 bar
•Pression dynamique
- mini. 0,5 bar
- recommandée 1 - 5 bar
- supérieure à 5 bar, mise en place d'un réducteur de
pression
•Pression de service maxi. 10 bar
•Pression d'épreuve 16 bar
•Température
- maxi. (admission d'eau chaude) 80 °C
•Raccord d'eau froide - à droite
chaude - à gauche
Remarque
Il convient d'éviter toute différence de pression importante
entre l'arrivée d'eau froide et chaude.
Montage,voir fig. [1].
Tenir compte de la cote du schéma sur le page 1.
L'arrivée d'eau froide doit être raccordée au robinet droit et
l'arrivée d'eau chaude au robinet gauche.
Bien rincer les canalisations avant et après l’installation!
Montage de la tirette et de la garniture de vidage,
voir fig. [2] et [3].
Vérifier l'étanchéité de la bonde de vidage.
Ouvrir les arrivées d'eau chaude et d'eau froide et vérifier
l'étanchéité des raccords.
Maintenance
Contrôler, nettoyer et, si nécessaire, remplacer les pièces.
Les graisser avec une graisse spéciale.
Fermer les arrivées d'eau froide et d'eau chaude.
I. Tête en céramique, voir fig. [4].
Remplacer la tête (A) complète et le joint torique (A1).
Tenir compte des différents numéros de pièce de
rechange des têtes.
II. Régulateur de jet, voir le page 2.
Desserrer et nettoyer le régulateur de jet (réf. 48 159).
Montage dans l'ordre inverse.
Pièces de rechange, voir page 2 (* = accessoires spéciaux).
Entretien
Vous trouverez les instructions d'entretien de ce mitigeur dans
le supplément Garantie Limitée.
7
2
1
27mm
3
4
A
A1
48 202
HOT
48 203
COLD
27mm
8
Español
Campo de aplicación
Es posible el funcionamiento en conjunción con:
- Acumuladores de presión
- Calentadores instantáneos con control térmico
- Calentadores instantáneos con control hidráulico
No instalar con acumuladores de baja presión
(calentadores de agua sin presión)
Datos técnicos
•Caudal máx. 5.7 L/min o 1.5 gpm/60 psi
•Presión
- mín. 7.25 psi
- recomendada 14.5 - 72.5 psi
- si la presión es superior a 72.5 psi, se deberá
instalar una válvula reductora de presión
•Presión de utilización máx. 145 psi
•Presión de verificación 232 psi
•Temperatura
- máx. (entrada del agua caliente) 176 °F
•Acometida del agua fría - a la derecha
caliente - a la izquierda
Nota
Deberán evitarse las diferencias de presión entre las
acometidas del agua fría y del agua caliente.
Instalación, ver fig. [1].
Respetar el croquis de la página 1.
La toma de agua fría debe conectarse a la válvula lateral
derecha y la toma de agua caliente a la válvula izquierda.
¡Purgar a fondo el sistema de tuberías antes y después
de la instalación!
Montar el tirador y el desagüe, ver fig. [2] y [3].
Asegúrese de que esté sellado el cuerpo de la válvula del
desagüe.
Abra las tomas de agua fría y caliente y compruebe que
no existen fugas en los empalmes.
Mantenimiento
Revisar, limpiar y cambiar eventualmente todas las piezas,
y engrasarlas con grasa especial para grifería.
Cierre el suministro de agua caliente y fría.
I. Montura cerámica, ver fig. [4].
Cambiar la montura cerámica (A) completa o la junta
toroidal (A1).
Prestar atención a los diferentes números de piezas de
repuesto de las monturas.
II. Regulador de caudal, ver la página 2.
Desatornille y limpie el regulador de caudal (48 159).
El montaje se efectúa procediendo en orden inverso.
Componentes de sustitución, ver la página 2
(* = accesorios especiales).
Cuidados periódicos
En el suplemento Garantía a Limitada encontrará las
instrucciones relativas al cuidado de esta batería.
2014/03/21
www.grohe.com
D
&
+49 571 3989 333
impressum@grohe.de
A
&
+43 1 68060
info-at@grohe.com
AUS
Argent Sydney
&
+(02) 8394 5800
Argent Melbourne
&
+(03) 9682 1231
B
&
+32 16 230660
info.be@grohe.com
BG
&
+359 2 9719959
grohe-bulgaria@grohe.com
CAU
&
+99 412 497 09 74
[email protected]
CDN
&
+1 888 6447643
[email protected]
CH
&
+41 448777300
[email protected]
CN
&
+86 21 63758878
CY
&
+357 22 465200
[email protected]
CZ
&
+420 277 004 190
grohe-cz@grohe.com
DK
&
+45 44 656800
[email protected]
E
&
+34 93 3368850
[email protected]
EST
&
+372 6616354
[email protected]
F
&
+33 1 49972900
marketing-fr@grohe.com
FIN
&
+358 10 8201100
teknocalor@teknocalor.fi
GB
&
+44 871 200 3414
[email protected]
GR
&
+30 210 2712908
nsapountzis@ath.forthnet.gr
H
&
+36 1 2388045
[email protected]
HK
&
+852 2969 7067
[email protected]
I
&
+39 2 959401
[email protected]m
IND
&
+91 124 4933000
[email protected]
IS
&
+354 515 4000
[email protected]
J
&
+81 3 32989730
[email protected]o.jp
KZ
&
+7 727 311 07 39
[email protected]
LT
&
+372 6616354
[email protected]
LV
&
+372 6616354
grohe@grohe.ee
MAL
&
+1 800 80 6570
info-singapore@grohe.com
N
&
+47 22 072070
grohe@grohe.no
NL
&
+31 79 3680133
[email protected]
NZ
&
+09/373 4324
P
&
+351 234 529620
[email protected]
PL
&
+48 22 5432640
[email protected].pl
RI
&
+62 21 2358 4751
info-singapore@grohe.com
RO
&
+40 21 2125050
info-ro@grohe.com
ROK
&
+82 2 559 0790
info-singapore@grohe.com
RP
&
+63 2 8041617
RUS
&
+7 495 9819510
info@grohe.ru
S
&
+46 771 141314
[email protected]
SGP
&
+65 6 7385585
info-singapore@grohe.com
SK
&
+420 277 004 190
[email protected]
T
&
+66 2610 3685
info-singapore@grohe.com
TR
&
+90 216 441 23 70
GroheTurke[email protected]
UA
&
+38 44 5375273
info-ua@grohe.com
USA
&
+1 800 4447643
us-customerservice@grohe.com
VN
&
+84 8 5413 6840
info-singapore@grohe.com
BiH
AL HR KS
ME MK SLO SRB
&
+385 1 2911470
[email protected]
Eastern Mediterranean,
Middle East - Africa
Area Sales Office:
&
+357 22 465200
[email protected]om
IR OM
UAE YEM
&
+971 4 3318070
grohedubai@grome.com
Far East Area Sales Office:
&
+65 6311 3600
[email protected]

Other Grohe Kitchen & Bath Fixture manuals

Grohe Tectron 37 324 User manual

Grohe

Grohe Tectron 37 324 User manual

Grohe Tectro User manual

Grohe

Grohe Tectro User manual

Grohe GROHTHERM CUBE 24 153 User manual

Grohe

Grohe GROHTHERM CUBE 24 153 User manual

Grohe Minta 32 917 User manual

Grohe

Grohe Minta 32 917 User manual

Grohe Grohtherm 3000 Cosmopolitan User manual

Grohe

Grohe Grohtherm 3000 Cosmopolitan User manual

Grohe GROHTHERM 2000 34 174 User manual

Grohe

Grohe GROHTHERM 2000 34 174 User manual

Grohe Blue 33 251 User manual

Grohe

Grohe Blue 33 251 User manual

Grohe Euroeco Special 32 788 User manual

Grohe

Grohe Euroeco Special 32 788 User manual

Grohe Tectron 36 201 User manual

Grohe

Grohe Tectron 36 201 User manual

Grohe Eurodisc SE 36 233 User manual

Grohe

Grohe Eurodisc SE 36 233 User manual

Grohe VELETTO 30366000 User manual

Grohe

Grohe VELETTO 30366000 User manual

Grohe Ondus 36 080 User manual

Grohe

Grohe Ondus 36 080 User manual

Grohe Grandera 19 931 User manual

Grohe

Grohe Grandera 19 931 User manual

Grohe EUROSMART COSMOPOLITAN E 36 336 User manual

Grohe

Grohe EUROSMART COSMOPOLITAN E 36 336 User manual

Grohe Europlus 19 716 User manual

Grohe

Grohe Europlus 19 716 User manual

Grohe GROHE Blue HOME 31 454 User manual

Grohe

Grohe GROHE Blue HOME 31 454 User manual

Grohe Blue Minta Mono Chilled & Sparkling 31 302 User manual

Grohe

Grohe Blue Minta Mono Chilled & Sparkling 31 302 User manual

Grohe Talia 33 233 User manual

Grohe

Grohe Talia 33 233 User manual

Grohe EUROSMART COSMOPOLITAN E + POWERBOX 36 386 User manual

Grohe

Grohe EUROSMART COSMOPOLITAN E + POWERBOX 36 386 User manual

Grohe Quadra 32 640 User manual

Grohe

Grohe Quadra 32 640 User manual

Grohe Zedra 33 707 User manual

Grohe

Grohe Zedra 33 707 User manual

Grohe SEABURY 25 055 User manual

Grohe

Grohe SEABURY 25 055 User manual

Grohe Tenso 32 924 Lavatory Centerset User manual

Grohe

Grohe Tenso 32 924 Lavatory Centerset User manual

Grohe RED DUO User manual

Grohe

Grohe RED DUO User manual

Popular Kitchen & Bath Fixture manuals by other brands

Sanela SLU 92B Instructions for use

Sanela

Sanela SLU 92B Instructions for use

FRANZ VIEGENER Nerea Installation

FRANZ VIEGENER

FRANZ VIEGENER Nerea Installation

IKEA LANGSKAR manual

IKEA

IKEA LANGSKAR manual

Nobili Hera 2005 Using instructions

Nobili

Nobili Hera 2005 Using instructions

Peerless Faucet P88LF-L quick start guide

Peerless Faucet

Peerless Faucet P88LF-L quick start guide

Delta Touch2O 1914T Series manual

Delta

Delta Touch2O 1914T Series manual

Glacier bay F51A0074CP Installation and care guide

Glacier bay

Glacier bay F51A0074CP Installation and care guide

Miomare 296071 Assembly, operating and safety instructions

Miomare

Miomare 296071 Assembly, operating and safety instructions

Franke F5 Series Installation and operating instructions

Franke

Franke F5 Series Installation and operating instructions

PEERLESS PTT14023 Series manual

PEERLESS

PEERLESS PTT14023 Series manual

Belanger Essential Style SVE78CMBG installation instructions

Belanger

Belanger Essential Style SVE78CMBG installation instructions

JADO New Classic 888/003 Series installation instructions

JADO

JADO New Classic 888/003 Series installation instructions

Kalia BF1800 installation instructions

Kalia

Kalia BF1800 installation instructions

Axor Citterio M 34448 1 Series Installation/User Instructions/Warranty

Axor

Axor Citterio M 34448 1 Series Installation/User Instructions/Warranty

Sanela SLU 08B Instructions for use

Sanela

Sanela SLU 08B Instructions for use

baliv KI-1060 N 415760 instruction manual

baliv

baliv KI-1060 N 415760 instruction manual

Spectrum Brands Pfister Saxton LG89-XGL Maintenance & Care Guide

Spectrum Brands

Spectrum Brands Pfister Saxton LG89-XGL Maintenance & Care Guide

Symmons Canterbury 45-458-TRM Operation and maintenance manual

Symmons

Symmons Canterbury 45-458-TRM Operation and maintenance manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.