manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. GST
  6. •
  7. I/O System
  8. •
  9. GST I-9301 User manual

GST I-9301 User manual

30303029 Issue 4.03
Features
Electronically addressed. The address can be
modified in field.
Built-in microprocessor processes messages
intelligently.
Insulation technology for input signal, good
anti-interference ability.
Cable checking.
Plug-in structure.
Description
With a microprocessor, I-9301 Addressable Single I/O
Module can communicate with fire alarm control panel
(FACP), check power cut, control output and LED.
The module closes the output relay and illuminates the
LED when receiving start command from fire alarm
control panel.
Connection and Wiring
Terminals on the module are shown as Fig. 1.
910 15 16
8721
D1 D2 Z1 Z2
V+ G COM1NO1 NC1 GST-LD-8301/I-9301
Mounting
Hole Mounting
Hole
Mounting
Direction
Fig. 1
Z1,Z2:Connecting with loop of FACP,
polarity-insensitive.
D1, D2: Polarity-insensitive 24VDC power line.
V+,G:24VDC output terminals, supplying output contact
with +24V output signal . There is 24V output at V+ and
G no matter whether the module is started or not.
NC1, COM1, NO1: Normally closed or normally open
output terminals.
Recommended Wiring
1.5mm2or above fire cable for 24VDC power line,
1.0mm2or above fire cable for other terminals, subject
to local codes.
Installation
The module is simply plugged onto the base after
corresponding terminals are connected.
Conduit Electric Box Module Conduit
B-9310
Back Box
Module
Fig.2 Fig.3
If the cable conduit is inside the wall, the base is
installed onto the electric box (Fig. 2). If the cable
conduit is on the surface of the wall, the B-9310 Back
Box is available.
Note the upward arrow for mounting direction (Fig.1).
Application
The module is designed to connect with the devices
controlled by fire alarm control panel, including smoke
exhauster, fan blower, and fire valve.
Address can be set through P-9910B programmer in
field, refer to P-9910B Hand Held Programmer
Installation and Operation Manual for specific
operation.
Mode of checking feedback signal can be set through
P-9910B programmer. After unlocking the programmer,
press Function and then number “4”, input “13” or “40”.
“13” means checking the feedback signal at any time,
“40” means checking feedback signal only in started
state. Press Program, if Pappears on the screen, the
setting is successful.
The module can directly drive a smoke exhauster
or fire valve (electrical tripping device). System
composition is shown in Fig. 4.
The Intelli
g
ent Solution
I-9301
Addressable Single I/O Module
548h/02
All manuals and user guides at all-guides.com
all-guides.com
30303029 Issue 4.03
Fig. 4
System composition for volt-free output contact
controlling field device is shown in Fig. 5.
Fig. 5
Note:
Don’t connect the module’s contact to the AC
control loop directly, preventing the strong AC
interference signal from damaging the module or
controlled device.
The module is not used for gas extinguishing
devices.
Specification
Operating Voltage Loop: 24V
Power: 24VDC
Quiescent Current Loop≤1mA Power≤2mA
Action Current Loop≤3mA Power≤15mA
Output Capacity Output contact capacity is 24VDC/5A
Voltage output capacity is 24VDC/1A
Output Control Mode Relay normally open/normally closed
volt-free output
Addressing Electronically addressed
Addressing Range Occupying one address, selectable
within 1~242.
LED Red, flashes when polling, illuminates in
action.
Ingress Protection
Rating IP30
Operating
Temperature 0℃~+49℃
Relative Humidity ≤93%, non condensing
Material and Color
of Enclosure ABS, White (RAL 9010)
Dimension
(L×W×H) 120mm×80mm×39mm
Weight About 194g (with base)
Accessories and Tools
Model Name Remark
P-9910B Hand Held
Programmer Supplied separately
B-9310 Back Box
Supplied separately
Limited Warranty
GST warrants that the product will be free from defects
in design, materials and workmanship during the
warranty period. This warranty shall not apply to any
product that is found to have been improperly installed
or used in any way not in accordance with the
instructions supplied with the product. Anybody,
including the agents, distributors or employees, is not
in the position to amend the contents of this warranty.
Please contact your local distributor for products not
covered by this warranty.
GST China
Gulf Security Technology Co., Ltd.
No. 80, Changjiang East Road,
QETDZ, Qinhuangdao, Hebei,
P. R. China 066004
Tel: +86 (0) 335 8502528
Fax: +86 (0) 335 8508942
[email protected]
www.gst.com.cn
GST UK
Global System Technology PLC
Lion Court, Staunton Harold Hall,
Melbourne Road, Ashby de la Zouch,
Leicestershire, England LE65 1RT
Tel: +44 1283 225 478
Fax: +44 1283 220 690
[email protected]
www.gst.uk.com
GST Dubai
Global System Technology PLC
PO Box 17998 Unit ZA04
JEBELALI Free Zone,
Dubai, UAE
Tel: +971 (0) 4 8833050
Fax: +971 (0) 4 8833053
[email protected]
www.gst.uk.com
This document is subject to change without notice. Please contact GST for more information or questions.
Z2
Z1
GND
+24V
Electrical Tripping Device
COM1
Z1
G
D1
V+
D2
NO1
Z2
I-9301
Z2
NO1
D2
V+
D1
G
Z1
COM1
Controlled Device
+24V
GND
Z1
Z2
Control Input
I-9301
All manuals and user guides at all-guides.com

Other GST I/O System manuals

GST I-9301 User manual

GST

GST I-9301 User manual

GST DI-9305E User manual

GST

GST DI-9305E User manual

GST I-9301 User manual

GST

GST I-9301 User manual

GST DI-M9305 User manual

GST

GST DI-M9305 User manual

GST I-9301 User manual

GST

GST I-9301 User manual

GST I-9301 User manual

GST

GST I-9301 User manual

GST DI-M9301 User manual

GST

GST DI-M9301 User manual

Popular I/O System manuals by other brands

SeaLevel DIO-32.PCI user manual

SeaLevel

SeaLevel DIO-32.PCI user manual

ICP DAS USA DN-8K32R quick start guide

ICP DAS USA

ICP DAS USA DN-8K32R quick start guide

ADLINK Technology ACL-7130 manual

ADLINK Technology

ADLINK Technology ACL-7130 manual

Advantech WISE-4210 Series user manual

Advantech

Advantech WISE-4210 Series user manual

Pilz PSSu H FS SN SD operating manual

Pilz

Pilz PSSu H FS SN SD operating manual

Honeywell PRO-2200 installation manual

Honeywell

Honeywell PRO-2200 installation manual

WEG CFW300-IOAENC Operation guide

WEG

WEG CFW300-IOAENC Operation guide

SMC Networks EX500-IE1 Installation & maintenance manual

SMC Networks

SMC Networks EX500-IE1 Installation & maintenance manual

WAGO 750-402 manual

WAGO

WAGO 750-402 manual

MG DLC-C1 Series instruction manual

MG

MG DLC-C1 Series instruction manual

National Instruments PXIe-4339 user manual

National Instruments

National Instruments PXIe-4339 user manual

Smarteh LONGO LPC-2 user manual

Smarteh

Smarteh LONGO LPC-2 user manual

National Instruments PXI-7854 Getting started

National Instruments

National Instruments PXI-7854 Getting started

Mitsubishi Electric MELSEC iQ-R Series user manual

Mitsubishi Electric

Mitsubishi Electric MELSEC iQ-R Series user manual

Digital Equipment StorageWorks DS-BA35X-MN installation guide

Digital Equipment

Digital Equipment StorageWorks DS-BA35X-MN installation guide

ICPDAS I-8093W Reference manual

ICPDAS

ICPDAS I-8093W Reference manual

National Instruments SCXI-1104 user manual

National Instruments

National Instruments SCXI-1104 user manual

Rockwell Automation FLEX 1794-TB2 installation instructions

Rockwell Automation

Rockwell Automation FLEX 1794-TB2 installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.