1)、 Pressing the “ ” button will start the constant temperature heating.
2)With the setting above, the circulation pump will work automatically.
3)、 If the temperature is set at 35℃,when the water temperature reaches or exceeds 36℃,the heater
will be turned off automatically and the circulation pump will stop after 5 seconds. When the water temperature
reaches or is lower than 34℃,the heater will start up again.
4)、 In the case of an error the LCD shows ”E1”. If this happens, the thermostatic heating system will
NOT be available, the heater doesn’t work.
15、Operating the Air Blower:
Press“ ” controls the blower.
16、Fahrenheit & Celsius Temperature shift:
In the status of“Power off”pressing the key“ ”can change the mode of Fahrenheit & Celsius degree.
17、When there is no water in the spa. All water pumps and heating system can not start up. However the
corresponding signals will flash on the LCD.
18、Prevent freezing function:
The heater & circulation pump will work automatically once the water temperature is below 5℃,when the water
temperature is reach at 10℃, heating will stop. This function is only available while the spa is on normal power
supply.
IV、Electric parameters
1、Performance index:
Rated voltage:220V/50Hz Maximum working current:60 A/220V-240V~
Voltage-resistance:1250V/1 minute without penetration。Isolative resistance:》 10MΩ
Water resistance grade:IPX5 Electric shock resistance:first grade
(2) Output loading index
Heater:AC220V/3KW x 1 Surf Water pump:AC220V/2 HP x 3
water pump:AC220V/1HP x 1 water pump:AC220v/0.35HP x 1
Air pump:AC220V/0.7kw x 1
spa light:AC12V/5W x 2 Ozone:AC12V/15W x 1
Radio:1) Frequency Range:FM:87.0~108.0MHz
2) Maximum Output Power:10W
3) Speaker:8Ωdamp proof speaker
5.Warning Information
a. Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules.