GUSH G.ems LED Profile 200 WW User manual

Gush G.ems LED Profile 200 WW
LED Profile Spot 200W (warm white LED)
User manual

statement
The product has well capability and intact packing when leave factory. All of the user
should comply with warning item and manual, any misuse cause of the damages are not
included in our guarantee, and also can not be responsible for any malfunction &
problem owing to ignore the manual.
1.
S
af
ety
I
nst
r
uctions
Please keep this User Guide for future consultation. If you sell the unit to another user, be
sure that they also receive this instruction booklet.
Unpack and check carefully there is no transportation damage before using the unit.
Before operating, ensure that the voltage and frequency of power supply match the
power requirements of the unit.
It’s important to ground the yellow/green conductor to earth in order to avoid electric
shock.
The unit is for indoor use only. Use only in a dry location.
The unit must be installed in a location with adequate ventilation, at least 50cm from
adjacent surfaces. Be sure that no ventilation slots are blocked.
Disconnect main power before replacement or servicing.
Make sure there are no flammable materials close to the unit while operating as it is fire
hazard.
Use safety cable when fixes this unit. DO NOT handle the unit by taking its head only, but
always by taking its base.
Maximum ambient temperature is Ta: 40℃. DO NOT operate it where the temperature is
higher than this Unit surface temperature may reach up to 85℃. DO NOT touch the
housing bare-hand during its operation. Turn off the power and allow about 15 minutes
for the unit to cool down before replacing or serving.
In the event of serious operating problem, stop using the unit immediately.Never try to
repair the unit by yourself. Repairs carried out by unskilled people can lead to damage
or malfunction. Please contact the nearest authorized technical assistance center.
Always use the same type spare parts.
DO NOT touch any wire during operation as high voltage might be causing electric shock.

Warning:
To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or
moisture.
DO NOT open the unit within five minutes after switching off.
The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly
damaged.
Caution:
There are no user serviceable parts inside the unit. DO NOT open the housing or attempt
any repairs yourself. In the unlikely event your unit may require service, please contact
your nearest dealer.
Installation:
The unit should be mounted via its screw holes on the bracket.Always ensure that the unit is
firmly fixed to avoid vibration and slipping while operating. And make sure that the
structure to which you are attaching the unit is secure and is able to support a weight of 10
times of the unit’s weight. Also always use a safety cable that can hold 12 times of the
weight of the unit when installing the fixture.
The equipment must be fixed by professionals. And it must be fixed at a place where is out of
the touch of people.
2. Technical Specifications
Lamp: 200w high power cob led
Power Supply: AC100V-250V, 50HZ/60HZ
Power consumption: 200w
7DMX control channels
Small volume, lightweight
High quality optical system
Different lens available(zoom 15°-50°)
N.W.:11kgs
3. Dmx512 connection
Please use xlr-xlr wires connect the dmx output the controller withe the dmx input of the
first device, and connect the dmx output of the first device with the dmx input of the

second device, always connect one output with the input of the next device until all
devices are connected.
Please use qualified xlr-xlr dmx cables.
4. Connection with mains
The person involved with the power connection must be qualified, and has the electrical
engineering certificate.
Connect the device to the mains with the power plug.
The earth has to be connected.
Power consumption 200w, input power supply AC100V-250V, 50HZ/60HZ.
5.The use of gobo frame
Take out the gobo frame, loose the screws, insert the gobos and lock the screws again.
Insert the gobo in the slot.
6.Replace fuse
Before replacing the fuse, unplug mains lead.
Procedure:
Step1: Unscrew the fuseholder on the rearpanel with a fitting screwdriver from the housing
(anti-clockwise).
Step2: Remove the old fuse from the fuseholder.
Step3: Install the new fuse in the fuseholder.
Step4: Replacing the fuseholder in the housing and fix it.
7.Focus
The objective lens cylinder is usually shrinked before leave factory, after connect the
projector to the mains, user may loose the screws and pull out the lens cylinder, till the
white light output circular is clearly presented, locking tightly the two screws again.
When the projection distance is changed, user can follow previous operation steps, and
focus the projector.
OPERATION

1.Description of the keys
MENU;
UP;
DOWN;
ENTER
2. Menu
Single color display operate
DMX512 Address to
Slave mode to
Master strobe to
Dimmer to
3IN1, 4IN1 Display Function:
DMX512 Address to
Slave mode to
Built-in auto mode. to

Sound mode to
Mixing color to
Color set to
Master strobe to
Red dimmer to
Green dimmer to
Blue dimmer to
White dimmer to
DMX Values and Functions
Single color 2CH:
Channel
Value
Function
1
1-255
Master dimmer
2
1-255
Master strobe
2IN1 WW+W 4CH:
Channel
Value
Function
1
000-255
Warm white

3IN1 RGB 6CH:
4IN1 RGBW 7CH:
8. Trouble shooting
Following are a few common problems that may occur during operation. Here are some
2
000-255
White
3
000-255
Master dimmer
4
000-255
Master strobe
Channel
Value
Function
1
000-255
Red
2
000-255
Green
3
000-255
Blue
4
000-255
Master dimmer
5
000-255
Master strobe
6
000-255
Modulation a built-in
programs
Channel
Value
Function
1
000-255
Red
2
000-255
Green
3
000-255
Blue
4
000-255
White
5
000-255
Master dimmer
6
000-255
Master strobe
7
000-255
Modulation a built-in
programs

suggestions for easy troubleshooting:
A. The unit does not work, no light and the fan does not work
1. Check the connection of power and main fuse.
2. Measure the mains voltage on the main connector.
3. Check the power on LED.
B. Not responding to DMX controller
1. DMX LED should be on. If not, check DMX connectors, cables to see if link properly.
2. If the DMX LED is on and no response to the channel, check the address settings and
DMX polarity.
3. If you have intermittent DMX signal problems, check the pins on connectors or on
PCB of the unit or the previous one.
4. Try to use another DMX controller.
5. Check if the DMX cables run near or run alongside to high voltage cables that may cause
damage or interference to DMX interface circuit.
C
.
One
of
the
cha
nnel
s
is
no
t
w
o
r
k
ing
w
el
l
1. The stepper motor might be damaged or the cable connected to the PCB is broken.
2. The motor’s drive IC on the PCB might be out of condition.
9. Fixture Cleaning
Th
e
clean
ing
o
f inter
na
l
a
nd
ex
ter
na
l
optica
l
lens
es
a
nd/or m
irr
ors
m
u
s
t
b
e
c
a
rr
ied
ou
t
p
eriodica
lly to optimiz
e
ligh
t
ou
tput
.
Cle
a
nin
g
f
r
eq
uency
d
e
p
end
s
on
t
h
e
environment
in
w
hich
t
h
e
f
ixture
ope
r
a
tes
:
d
a
mp
,
s
m
oky
o
r
p
a
r
tic
ula
r
ly d
ir
ty
s
urr
ounding
c
a
n
c
a
us
e
g
r
eat
er
acc
um
ula
tio
n
of
d
irt
on
th
e
u
nit’
s
optics
.
Cle
a
n
with
s
oft
clo
th
u
s
ing
no
r
m
a
l
g
l
ass
clea
ni
ng
fluid
.
A
lw
a
y
s
d
r
y
th
e
parts
ca
r
ef
ully
.
Cle
a
n
th
e
ex
ter
na
l
optic
s
a
t
leas
t
ev
ery
20
days.
Cle
a
n
th
e
in
ter
na
l
opti
cs
a
t
lea
s
t
ev
ery
30/60
days.
Table of contents
Other GUSH Dj Equipment manuals