GVA Lighting FL Series User manual

Architectural Spot and Flood Light INSTALLATION GUIDE
GVA Lighting, Inc. 3400 Ridgeway Drive, #14 Missisauga, Ontario L5L 0A2
IG, FL SERIES, 18-12-21 | Page 1 / 9
FL Series F L10 0 ™
FL 200 ™
FL50 ™
FL2 5 ™

Architectural Spot and Flood Light INSTALLATION GUIDE
GVA Lighting, Inc. 3400 Ridgeway Drive, #14 Missisauga, Ontario L5L 0A2
IG, FL SERIES, 18-12-21 | Page 2 / 9
Specifications are subject to change without notice. Every effort has been made to ensure that the information provided in this manual is accurate.
GVA Lighting Inc. is not responsible for printing or clerical errors. Refer to www.gvalighting.com for additional information.
FL Series F L10 0 ™
FL 20 0 ™
FL50 ™
FL2 5 ™
WARNING CAUTION
Do not attempt to install or use Luminaire(s) until you have read and
understand this guide and all safety labels.
Luminaire(s) must be installed by a qualified professional.
Luminaire(s) must be installed in accordance with all national and
local electrical and construction regulations.
Ensure that main power supply is OFF before installing or wiring
luminaire(s).
Do not exceed specified voltage and current input.
Do not use luminaire(s) with a damaged lens, body, or cable.
Failing to install luminaire(s) according to warnings may result in
a hazardous situation which can cause equipment and property
damage, personal injury, or death.
Do not exceed the maximum number of specified luminaires in a light
run. Doing so will result in a current overload.
GVA Luminaires have no serviceable parts. Do not attempt to open
the units.
Do not hot swap. Ensure power supply is off before connecting or
disconnecting fixtures.
Do not stare into beam or view directly with optical instruments.
Unauthorized feild repairs will void warranty.
1LUMINAIRE
INSTALLATION
1.1 MOUNTING PLATE
WARNING Use mounting hardware suitable for the mounting surface. Use of innappropriate hardware may result in dismounting of
the bracket and can result in equipment damage, injuries, or death.
CAUTION Failure to select the appropriate hardware may result in the screw heads not being flush with the mounting profile which
will hinder the installation of the fixture.
1.1.A SM Mounting Plate
NOTE: If installing SM HD Mounting Plate refer to Step 1.1.B.
Install mounting plate using M5 or No.10 Flathead Screws (supplied by others) suitable for the mounting surface. Refer to "SM MOUNTING
HOLE TEMPLATE" to mark holes prior to installation, if necessary.
62mm
2.5in
62mm
2.5in
Ø 75mm
3.0in
SM MOUNTING
HOLE TEMPLATE
(1:1 SCALE)
NOTE: GVA Lighting cannot guarentee that this installation guide is printed to
scale. Measure template to ensure that it is 1:1 scale.
SM MOUNTING
PLATE
(supplied)
M5 OR NO.10
SCREW
(supplied by others)
3.6mm
0.14in
Max.
REQUIRED HARDWARE:
M5 OR NO.10
FLATHEAD SCREW
(supplied by others)
4X

Architectural Spot and Flood Light INSTALLATION GUIDE
GVA Lighting, Inc. 3400 Ridgeway Drive, #14 Missisauga, Ontario L5L 0A2
IG, FL SERIES, 18-12-21 | Page 3 / 9
Specifications are subject to change without notice. Every effort has been made to ensure that the information provided in this manual is accurate.
GVA Lighting Inc. is not responsible for printing or clerical errors. Refer to www.gvalighting.com for additional information.
FL Series F L10 0 ™
FL 20 0 ™
FL50 ™
FL2 5 ™
1.1 MOUNTING PLATE CONTINUED
1.1.B SM HDMounting Plate
NOTE: If installing SM Mounting Plate refer to Step 1.1.A.
Install mounting plate in desired location using M6 or No.12 Screws (supplied by others) suitable for the mounting surface. Refer to "SM HD
MOUNTING HOLE TEMPLATE" to mark holes prior to installation, if necessary.
76mm
3.0in
76mm
3.0in
SM HD MOUNTING
HOLE TEMPLATE
(1:1 SCALE)
Ø 105 mm
4.1 in
M6 OR NO.12 SCREW
(supplied by others)
REQUIRED HARDWARE:
1X
6.8mm
0.25in
Max.
SM HD MOUNTING
PLATE
(supplied)
M6 OR NO.12
SCREW OR BOLT
(supplied by others)
NOTE: GVA Lighting cannot guarentee that this installation guide is printed to scale.
Measure template to ensure that it is 1:1 scale.

Architectural Spot and Flood Light INSTALLATION GUIDE
GVA Lighting, Inc. 3400 Ridgeway Drive, #14 Missisauga, Ontario L5L 0A2
IG, FL SERIES, 18-12-21 | Page 4 / 9
Specifications are subject to change without notice. Every effort has been made to ensure that the information provided in this manual is accurate.
GVA Lighting Inc. is not responsible for printing or clerical errors. Refer to www.gvalighting.com for additional information.
FL Series F L10 0 ™
FL 20 0 ™
FL50 ™
FL2 5 ™
1.2 MOUNTING BRACKET
1.2.A Surface Mount (SM) Bracket
Use the provided hardware to install the FL bracket to the mounting plate. Be advised that the main security mounting screw (241577) requires
a 4mm pin-in-hex allen key for installation, the same allen key can be used to mount the remaining hardware.
241576
121518 / 121519
241577
241576
*FL100™ shown
in diagram.
REQUIRED TOOLS:
241620
4MM PIN-IN-HEX
SECURITY ALLEN KEY
(supplied)
241576
NO.4 NYLON FLAT WASHER
(supplied)
121518/121519
ROTATION SLEEVE
(supplied)
2X
1X
241577
4MM SECURITY SCREW
0.25IN-20X0.675IN
(supplied)
1X
REQUIRED HARDWARE:
1.2.B Surface Mount Heavy Duty (SM HD) Bracket
Use the provided hardware to install the FL bracket to the mounting plate.
NOTE: APPLY
LOCTITE 271
(supplied by others)
PRIOR TO INSTALL
241812
0.25-20IN HEX NUT
(supplied)
2X
REQUIRED HARDWARE:
241576
NO.4 FLAT NYLON WASHER
(supplied)
2X
241810
NO.4 FLAT WASHER
(supplied)
1X
241812
241812
241576
241576
241810
*FL100™shown
in diagram.

Architectural Spot and Flood Light INSTALLATION GUIDE
GVA Lighting, Inc. 3400 Ridgeway Drive, #14 Missisauga, Ontario L5L 0A2
IG, FL SERIES, 18-12-21 | Page 5 / 9
Specifications are subject to change without notice. Every effort has been made to ensure that the information provided in this manual is accurate.
GVA Lighting Inc. is not responsible for printing or clerical errors. Refer to www.gvalighting.com for additional information.
FL Series F L10 0 ™
FL 20 0 ™
FL50 ™
FL2 5 ™
1.3 ADJUSTMENT SCREWS
Aim the fixture in the desired direction and install the adjustment hardware.
1.3.A Surface Mount (SM) Adjustment Screws
241573
241572
241603
241603
NO.10 FLAT WASHER
(supplied)
2X
REQUIRED HARDWARE:
241573
SPLIT WASHER
(supplied)
2X
241572
NO.10-32 SOCKET
HEAD SCREW
(supplied)
1X
NOTE: There are two sets of
holes on the mounting plate,
each allows the fixture to
rotate in 90° increments for a
total of 360° of rotation.
1.3.B Surface Mount Heavy Duty (SM HD) Adjustment Screws
241603
NO.10 FLAT WASHER
(supplied)
2X
REQUIRED HARDWARE:
241573
SPLIT WASHER
(supplied)
2X
241643
NO.10-32 SOCKET
HEAD SCREW
(supplied)
1X
241643
241573
241603
NOTE: There are two sets of
holes on the mounting plate,
each allows the fixture to rotate
in 90° increments for a
total of 360° of rotation.

Architectural Spot and Flood Light INSTALLATION GUIDE
GVA Lighting, Inc. 3400 Ridgeway Drive, #14 Missisauga, Ontario L5L 0A2
IG, FL SERIES, 18-12-21 | Page 6 / 9
Specifications are subject to change without notice. Every effort has been made to ensure that the information provided in this manual is accurate.
GVA Lighting Inc. is not responsible for printing or clerical errors. Refer to www.gvalighting.com for additional information.
FL Series F L10 0 ™
FL 20 0 ™
FL50 ™
FL2 5 ™
2FIXTURE
CONNECTIONS
2.1 INPUT AND OUTPUT FIXTURE CONNECTIONS
WARNING Ensure power supply is turned OFF before making any connections. Connecting the luminaire while the power is turned
ON may result in equipment damage.
When the bracket has been fastened to the mounting plate, connect the input and output jumper cables and/or leader cables to the fixture.
Connector will make an audible 'CLICK' when inserted correctly. Add INF Dust Cap at the end of each run.
2.1.A INF Fixture Connections
INF IP67 DUST CAP
(must be used at the
end of each run)
remove the tail from the
dust cap before installation
*FL100™ shown
in diagram.
LUMINAIRE
LEADER CABLE
(Power-Data from
power supply)
LUMINAIRE
JUMPER CABLE
INPUT
CONNECTION
INPUT
CONNECTION
OUTPUT
CONNECTION
2.1.B ELV Fixture Connections
LUMINAIRE
LEADER CABLE
(Power-Data from
power supply)
LUMINAIRE
JUMPER CABLE
INPUT
CONNECTION
INPUT
CONNECTION
OUTPUT
CONNECTION
ELV IP67 DUST CAP
(must be used at the
end of each run)
*FL100™ shown
in diagram.

Architectural Spot and Flood Light INSTALLATION GUIDE
GVA Lighting, Inc. 3400 Ridgeway Drive, #14 Missisauga, Ontario L5L 0A2
IG, FL SERIES, 18-12-21 | Page 7 / 9
Specifications are subject to change without notice. Every effort has been made to ensure that the information provided in this manual is accurate.
GVA Lighting Inc. is not responsible for printing or clerical errors. Refer to www.gvalighting.com for additional information.
FL Series F L10 0 ™
FL 20 0 ™
FL50 ™
FL2 5 ™
3ACCESSORY
INSTALLATION
3.1
NOTE: Accessory installation is optional.
WARNING If fixture is installed in high wind or vibration location, apply Locktite 271 (supplied by others) on moving screws. Failure to
do so may result in equipment damage, serious injury or death.
Up to three barndoor or visor accessories can be installed onto one FL Series fixture. Line the holes on the back of the fixture up to the holes
on the accessory. Use the supplied hardware to attach the accessory to the fixture.
*FL100™shown
in diagram.
241603
FLAT WASHER
(per accessory/ supplied)
2X
REQUIRED HARDWARE:
240776
M4 SCREW
(per accessory/ supplied)
2X
VISOR
BARNDOOR
*FL100™shown
in diagram.
NOTE: If the barndoor
mechanism is too
loose, tighten the cap
screw and locknut up
to desired preset.

Architectural Spot and Flood Light INSTALLATION GUIDE
GVA Lighting, Inc. 3400 Ridgeway Drive, #14 Missisauga, Ontario L5L 0A2
IG, FL SERIES, 18-12-21 | Page 8 / 9
Specifications are subject to change without notice. Every effort has been made to ensure that the information provided in this manual is accurate.
GVA Lighting Inc. is not responsible for printing or clerical errors. Refer to www.gvalighting.com for additional information.
FL Series F L10 0 ™
FL 20 0 ™
FL50 ™
FL2 5 ™
4FIXTURE
AIMING
4.1 HORIZONTAL AIMING
To aim the fixture horizontaly, loosen the two adjustment screws and rotate to desired location. Torque the screws to 2 Nm with a torque
wrench to lock the bracket in place.
*FL100™shown
in diagram.
4.2 VERTICAL AIMING
Rotate to desired angle and torque the set screw to 1.5 Nm with a torque wrench to lock the fixture in place. For subsequent vertical
adjustment, simply release the set screw and rotate the fixture head. Ensure that the set screw is locked after every adjustment.
SET SCREW
NOTE: do not
tamper with the
Pin-in-torx screw
*FL100™shown
in diagram.

Architectural Spot and Flood Light INSTALLATION GUIDE
GVA Lighting, Inc. 3400 Ridgeway Drive, #14 Missisauga, Ontario L5L 0A2
IG, FL SERIES, 18-12-21 | Page 9 / 9
Specifications are subject to change without notice. Every effort has been made to ensure that the information provided in this manual is accurate.
GVA Lighting Inc. is not responsible for printing or clerical errors. Refer to www.gvalighting.com for additional information.
FL Series F L10 0 ™
FL 20 0 ™
FL50 ™
FL2 5 ™
NOTES
Other manuals for FL Series
1
This manual suits for next models
4
Table of contents
Popular Floodlight manuals by other brands

Francis Searchlights
Francis Searchlights FH380 User instruction & installation manual

ARRI
ARRI M90 - Short instructions

Whelen Engineering Company
Whelen Engineering Company NITEBEAM H.I.D. Mounting guide

Philips
Philips eXpanium eXp 401 Brochure & specs

Lumineux
Lumineux Carsington Plus Sports quick start guide

JB Systems
JB Systems LED Diamond Operation manual