Typenbezeichnung:
Variante:
Herstellnummer:
Wärmeleistungsbereich:
Nennwärmeleistung
Zugelassener Brennstoff:
Staub bez.auf 13% O2: 22 mg/Nm³ Wirkungsgrad: 80,3% CO bez. auf 13% O2: 0,10%
Abgastemperatur am Stutzen: 320°C Nox bez. 13% O2: 96 mg/Nm³ HC bez. auf 13% O2: 42 mg/Nm³
Mindestabstände seitlich: siehe Aufstellungs-und
zu brennbaren Bauteilen: hinten: Bedienanleitung
vorne im Strahlungsbereich: 80 cm
Anbringungsjahr
2013
Holz, Holzbrikett nach - DIN 51731,
Prüfstellenkennziffer:1625 / Prüf Nr. RRF- 29 12 3110
Lesen und befolgen Sie die Bedieungsanleitung!
Mehrfachbelegung des Schornsteins ist zulässig
HAAS + SOHN OFENTECHNIKGMBH
URSTEIN NORD 67 A-5412 PUCH
KamineinsatzBauart : EN 13229-W / Zeitbrandfeuerstätte
8,0 kW
180.18
1303180800085
3,9 - 8,3 kW
Komfort-III 180.18-AL
Prüf Nr. VKF:
Description of the system for supplying the air needed for combustion:
The system for supplying the air needed for combustion in stove unit type 180.18-AL has three settings: the primary
air is adjusted by means of the air intake control(11) With the handle in position 2 (‘right’) the primary air. I enters
through the grate, and the primary air II enters through that area of the combustion chamber which is to wards the
front of the stove. With the handle in position 1 (‘middle’) the primary air I only enters via the grate. The amount of
secondary air is set at an optimum level for the unit to provide the necessary ventilation to keep the window clean and
to provide the necessary air for secondary combustion; it is permanently adjusted for increased comfort. The pre-
heated secondary air flows past the top end of the inspection window (8).
Air intake control
Primary air I
Primary air II
Use:
2
"right"
open
open
For use when it is heating up and after
fuel has been added
1
"middle"
shut
open
In normal operation
0
"left"
shut
shut
Only for keeping the embers glowing
Connection for providing the air needed for combustion:
In airtight buildings there can be reduction in the oxygen content of the room in which the stove is set up; it must
therefore be ensured that there is adequate ventilation. The stove unit type 180.18-AL therefore offers you the
possibility of drawing in the air needed for combustion from outside. The stove can then be operated without having to
depend on the air within the room. In order to do this the air from outside that is needed for combustion is supplied by
means of a flexible pipe attached to the socket for the pipe (18). It is possible for you to change the position of the pipe
socket to the left, right or rear of the stove unit. The end of the pipe carrying the air must be located in the open air, or
in a well ventilated room situated within the building. Operation of the stove unit in connection with an air conditioning
and ventilation system is permitted. When installing the stove unit in connection with an automatic air conditioning and
ventilation system the end of the pipe supplying the air must not be located in a room which is connected to this
system.
The amount of fuel and adjustment of the air intake control:
Lighting, and heating the appliance up: see sections 5.4, 5.5 and 5.6 in the instructions for use of the stove.
Use the gloves provided to protect you against the heat when operating the air intake control.
Before every addition of fuel, the air intake control is to be closed completely (handle setting ‘left’).
Tip for burning wood: Every time the stove is lit leave the appliance in the ‘right’ position until the fuel is
burning well (around 10 minutes). (This time can vary somewhat depending on the amount of draught
and the pressures involved).When adding fuel shut the air intake as indicated.
Brennstoffe maximale Brennstoffmenge Primärluft: Luftregler Sekundärluft (ohne
Regelung)
Scheitholz 2 - 3 Scheite (ca. 2 – 2,5 kg) 10 Minuten lang Hebelstellung „2“
(rechts), dann Hebelstellung „1“
(Mitte) offen
Holzbriketts 1 Holzbrikett (2 kg)
Komfort – IV 180.18 AL