Mounting Instructions
Door Terminal Basic European version

Contents
Contents
Area of use......................................................................................3
Technical information....................................................................3
Scope of delivery.............................................................................4
Mounting.........................................................................................6
Disassambly....................................................................................20
Commissioning...............................................................................21
Brief operating instructions...........................................................22
Operation ........................................................................................ 24
Changing batteries ............................................................................ 48
Emergency opening via the profile cylinder ........................................ 51

Mounting Instructions
26
Attention!
•It is essential that you read the "Commissioning" section of these
instructions before commissioning (allocation of keys).
Area of use
The Door Terminal Basic is an electronic door fitting used principally
in the hotel sector. It is mounted on interior doors with mortise locks
acc. to DIN 18 251 and can also easily be retrofitted on the door leaf.
Depending on the design, the fixing plate on the Door Terminal Basic
can also be mounted on doors whose mortise locks deviate from DIN
18 251.
Technical information
•All Door Terminals Basic are supplied in the simple operating
mode. In this operating mode, access rights for up to 26 electronic
keys can be allocated directly at the Door Terminal Basic with a
special Programming ADD Key-stick (green). These access rights
can be withdrawn again from an authorised electronic key at the
Door Terminal Basic using a Programming DELETE Key-stick
(red). Please contact your Dialock distributor if a different operating
mode is to be selected.
•The Door Terminal Basic consists of the outer module (fixing plate
with bracket and cover) that is mounted on the outer side of the
door, and rosette fittings that are mounted on the inside of the door.
•The Door Terminal Basic has no infrared interface but can be
configured using Parameter and Special Transponders.
•The Door Terminal Basic is battery-powered, and operated using
electronic keys.

Mounting Instructions
27
Scope of delivery
4
3
1
6
5
7
9
2
2
3
10
10
8
8
Door Terminal Basic :
1
1 outer module (fixing plate with bracket and cover)
2
1 set of rosette fittings
3
2 door handles
Small parts bag:
4
1 chipboard screw, 3 x 20
5
1 retaining ring
6
1 pin, 3 x 22
7
1 pin, 4 x 22
8
2 adhesive labels (to assist mounting)
Fastening parts:
9
1 square Spindle
10
4 countersunk screws M4
The length of the fastening parts depend on the thickness of the door
leaf.

Mounting Instructions
28
Accessories (not included in the scope of delivery):
User and Programming Key-sticks
2 lithium batteries
1 release lever
1 pair of retaining ring pliers

Mounting Instructions
29
Spare parts (not included in the scope of delivery):
1
3
2
4
1
1 cover (available in a variety of colors)
2
1 bag of fastening parts
(square spindle and countersunk screws, M4)
3
1 small parts bag
4
1 fixing plate

Mounting Instructions
30
Mounting
Requirements:
•DIN mortise lock
Depending on the design of the fixing plate, it is also possible to use
mortise locks on the Door Terminal Basic that deviate from the DIN
norm (e.g. for Austria).
The length of the following Door Terminal Basic components
depends on the thickness of the door leaf and must therefore be
selected appropriately:
•the screws for attaching the rosettes
•the square spindle
Tools required and auxiliary mounting materials:
•a drilling template
•an electric drill
•drill bits suitable for the door material:
- Ø = 8 mm
- Ø = 7 mm (depending on the rosette fittings used)
- Ø = 6 mm
•a hammer
•retaining ring pliers
•a screwdriver
•a 3 mm Allen wrench

Mounting Instructions
31
Adapting the Door Terminal Basic for right-facing door handles
The Door Terminal Basic is adapted for left-or right-facing door
handles using the pins on the back of the fixing plate (with the
bracket).
1. Place the door handle on the bracket in such a way that the
direction of door handle movement is appropriate for its use.
2. Turn the external square with the door handle at its upper limit
(zero position) and hold it.

Mounting Instructions
32
R80
R
L
L80
R45
L45
3. Using a hammer, lightly tap a 3 x 22 pin into the drilled hole
labelled "R" on the back of the fixing plate. The spring of the door
handle is under pressure.
4. Insert a 4 x 22 pin in the drilled hole labelled "R45°" on the back
of the fixing plate for the door handle limit.
If the door handle angle of rotation is to be greater than 45°:
ÖInsert a 4 x 22 pin in the drilled hole labelled "R80°" on the
back of the fixing plate.
5. Secure the pins with the adhesive labels so that they do not fall
out.

Mounting Instructions
33
6. Remove the door handle from the external square spindle.
The Door Terminal Basic is adapted for a right-facing door
handle.
Proceed as follows if the pins have been inserted in the wrong
side:
ÖRemove the 8 screws in the fixing plate.
ÖRemove the fixing plate from the bracket.
ÖPull the pins out of the bracket, using pliers if necessary.
ÖPlace the fixing plate on the bracket.
ÖTighten the screws.
ÖRepeat the adaptation process for the correct hole location.

Mounting Instructions
34
Adapting the Door Terminal Basicfor left-facing door handles
The Door Terminal Basic is adapted for left-or right-facing door
handles using the pins on the back of the fixing plate (with the
bracket).
1. Place the door handle on the bracket in such a way that the
direction of door handle movement is appropriate for its use.
2. Turn the external square with the door handle at its upper limit
(zero position) and hold it.

Mounting Instructions
35
R
L
L80 R80
R45
L45
3. Using a hammer, lightly tap a 3 x 22 pin into the drilled hole
labelled "L" on the back of the fixing plate. The spring of the door
handle is under pressure.
4. Insert a 4 x 22 pin in the drilled hole labelled "L45°" on the back of
the fixing plate for the door handle limit.
If the door handle angle of rotation is to be greater than 45°:
ÖInsert a 4 x 22 pin in the drilled hole labelled "L80°" on the back
of the fixing plate.
5. Secure the pins with the adhesive labels so that they do not fall
out.

Mounting Instructions
36
6. Remove the door handle from the external square spindle.
The Door Terminal Basic is adapted for a left-facing door handle.
Proceed as follows if the pins have been inserted in the wrong
side:
ÖRemove the 8 screws in the fixing plate.
ÖRemove the fixing plate from the bracket.
ÖPull the pins out of the bracket, using pliers if necessary.
ÖPlace the fixing plate on the bracket.
ÖTighten the screws.
ÖRepeat the adaptation process for correct hole location.

Mounting Instructions
37
Mounting the square spindle
1. Insert the square spindle in the inner coupling component in such
a way that the pins are located in the cavities of the coupling
component.
2. Using the retaining ring pliers, insert the retaining ring in the slot
of the inner coupling component. In the process, ensure that the
opening of the retaining ring is not lying over any of the upper
square spindle pins.
This completes the square spindle mounting process.

Mounting Instructions
38
Mounting the Door Terminal Basic
The following steps are necessary for mounting the Door Terminal
Basic :
•drilling holes for the rosette fittings and guiding pins
•attaching the Door Terminal Basic
•attaching the rosette fittings
•setting up the Door Terminal Basic for operation
Mounting on wooden doors is described below.
Condensation forming on cold components can damage the
Door Terminal Basic.
ÖEnsure that all components are at room temperature.
Drilling the holes for the rosette fittings and guiding pins
1. Lay the drill template, with the mandril for the lock spindle, on the
door leaf.
2. Drill holes in the door leaf on both sides using the appropriate drill
bit (Ø = 6 mm or Ø = 7 mm).

Mounting Instructions
39
3. Drill holes at least 6 mm deep in the outer side of the door with
drill bit Ø = 8 mm.
4. Drill holes in the inner side of the door with drill bits Ø = 8 mm or
Ø = 7 mm (depending on the rosettes used).
Attaching the Door Terminal Basic
a
a
Slot of the square spindle
1. Place the fixing plate and bracket on the outer door leaf in such a
way that the retaining pins of the fixing plate are located in the
drilled holes in the door, and the square spindle is sitting in the
lock spindle in such a way that the slot for the set screw is
pointing in the direction of the strike.
2. Ensure that the fixing plate is lying flat on the door leaf.
If the fixing plate is not lying flat:
ÖCheck the drilled holes and if necessary remove wood
shavings.

Mounting Instructions
40
3. Place the bolting elements of the rosette fittings on the inner door
leaf in such a way that the screw guides are located in the drilled
holes.
4. To connect the fixing plate (and bracket) to the bolting elements:
attach the bolting elements firmly with two screws each.
5. To attach the fixing plate to the door: tighten 3 x 20 chipboard
screws in one of the three upper drilled holes of the fixing plate.
The Door Terminal Basic has been attached.

Mounting Instructions
41
Attaching the rosette fittings
1. Place the ornamental plates of the rosette fittings on the bolting
elements in such a way that they snap into place.
2. Place the door handle on the square spindle in such a way that
the set screws point in the direction of the strike.
3. Tighten the set screws.
4. Install the profile cyclinder, if available.
The rosette fittings have been attached.

Mounting Instructions
42
Setting up the Door Terminal Basic for operation
1. Insert two lithium batteries type ½ AA 3V in the battery
compartment.
Use correct polarity! (See also "Changing the batteries")
2. Place the lower part of the cover on the bracket in such a way
that the cover guides are located in the ledges of the bracket.
3. Press the upper part of the cover back on the bracket, until it
audibly snaps into place. Take care not to damage the sensitive
plug-in connections.
4. Place the door handles on the external square in such a way that
the set screw points in the direction of the strike.
5. Tighten the set screw.
The Door Terminal Basic has been set up for operation.