Ham ThermoSense User manual

1
ThermoSense
• Wi-Fi (IEEE 802.11 b/g/n)
Internet Connecon
• Temperature measurement in
the range -50oC to 200oC with PT-
100 probe
• Temperature and Relave
Humidity measurement at device
locaon
• Power supply through micro-USB
cable or DC power supply unit
• RESET and SETUP buon
• Easy installaon
• Up to 2 dry contact inputs (for door
sensing and more)
Warranty: 2 years
1. P1 probe wire
2. P1 probe wire (same color as 1)
3. P2 probe wire
4. NC
5. V+ power supply (alternave
to micro-USB)
6. G1 dry contact 1
7. G2 dry contact 2
8. GND dry contact common,
supply ground/negave
9. RESET
10. SETUP
11. Connecon Status LED
9
10
11

2
In order for the device to work, you will need a Wi-Fi router with an internet
connecon. You will also need a smartphone with Android or iOS for the setup
procedure.
1. Make the connecons like shown in the diagram on page 1.
2. Check your wiring and turn on the power supply or connect the micro-USB cable
3. Open the smartphone app. If you don’t already have an account, create one.
4. In the Android or iOS app , choose the Setup Device (+) opon and follow the
instrucons there.
5. Check the device is connected to the router and the internet by looking at the green
LED. If the device is connected to the HAM plaorm, the green LED should be lit.
6. If the previous steps were successful and the device is connected to the internet,
then you will be redirected to the a screen where you can monitor your device.
In case there is an issues on the steps 2/4/5, try pushing the Reset buon and wait a
few seconds.
SETUP INSTRUCTIONS
SAFETY WARNINGS
• In case you didn’t connect the device
correctly it may be damaged or
destroyed. Recheck your connecons
before restoring power.
• Temperature, relave humidity and dry
contact readings are for indicave use
only and should not be relied upon
when human or animal life is at risk.
• If internet connecon is lost, you will
not be able to monitor the real-me
readings of the device nor will the
readings be logged at the cloud.
• Do not take apart the device and do not
use devices you have altered in any way.
• Disassembly of the device will void your
warranty

3
To use the device, visit hps://
hamsystems.eu or download the app for
your smartphone.
For Android: hps://play.google.com/
store/apps/details?id=com.ham.app
For iOS: hps://itunes.apple.com/us/
app/ham-systems/id1262469559
Pressing the RESET will restart your de-
vice (your sengs will be preserved).
Some of our cloud plaorm features:
• Monitor and log temperature with high
resoluon
• Setup alerts when a dry contact chang-
es state, e.g. a door opens
• Setup alerts when temperature is out
of the desired range via SMS, e-mail,
phonecalls and push nocaons
• Create interacons between devices in
an If-This-Then-Than (IFTTT) format.
• Share device usage with other users.
• Secured communicaons with TLS.
• Organize devices in groups and oor-
plans.
USAGE
TECHNICAL SPECIFICATIONS
Sensors Pt100 3-wire for external temperature measurement
Internal for temperature and humidity measurement
Resoluon Temperature 0.1oC, Humidity 0.1%
Seng range Pt100: -50oC με +200oC
Internal: -10oC to +50oC and 0%-90% RH
Accuracy Temperature ± 1 oC, Humidity ± 5%
Working environment -10oC to +50oC, 5%-90% RH
Number of dry contacts 2
Power supply 5-12 VDC, 0.2 A
Dimensions 21.5 mm x 44.1 mm x 55 mm
Case ABS

4
TROUBLESHOOTING
The green LED does not turn on and
the device is reported as disconnected
on the internet plaorm
If the green LED is not lit, then the
device may be unable to be connected
to the Internet Plaorm.
• Check your internet connecon. If
you don’t seem to be able to access
the internet through the Wi-Fi router
then contact your Internet Service
Provider (ISP).
• Check that the server is accessible at
hps://hamsystems.eu or open the
smartphone app. If you are unable to
access the server, try again aer 5
minutes.
• Try to reset the device by using the
reset buon and wait a few seconds.
Repeat a few mes.
• Check that the device is connected to
your Wi-Fi router. A way this can be
achieved is by accessing the router’s
conguraon page. If none of the
above suggesons worked, then
repeat the steps 2-5 of the setup
instrucons.
The temperature measurement is way
o
• Check that you have connected the
PT-100 probe correctly and that
there is a good connecon between
the wires and the terminals
• Check that the PT-100 probe is not
damaged or cut.
• Check that your device is connected
and the connected status LED is fully
lit.
No dry contact reading
• Check your dry contact connecons.
• Check that the wires used are not cut
at any point.
• Check that your device is connected
and the connected status LED is fully
lit
• You may need to cycle the dry con-
tact once for it to appear on the app/
website
More in-depth documentaon, help, declaraons of conformity, instrucons for the
Internet plaorm, Terms and Condions, Privacy policy and more are available at
hps://hamsystems.eu
Popular Data Logger manuals by other brands

American Thermal Instruments
American Thermal Instruments LOG-IC 360 user guide

Rotronic
Rotronic RMS-MLOG-B-915 Short instruction manual

ThingsLog
ThingsLog LPMDL-1101 user manual

Data Harvest
Data Harvest EasySense Q 3 manual

sewerin
sewerin SePem 100 operating instructions

MadgeTech
MadgeTech QuadRTD Product Information Card