HandyHeat DVTH132 A User manual

T hank you for choosing the DVTH132, a programmable
thermostat that provid es both energy savings and total
comfort.
DAY/H O UR/MIN —Set the day and clock settings.
PGM—Program the schedule (progra ms).
MODE—Select the ope rating mode .
RETURN—To exit a function.
To configure temperature setpoints:
Comfort, Economy and Va ca tion.
Adjust the floor te mperature limit (AF only).
—Increase and decrease temperature.
—Indicates the number of the curren t
program when Automatic mode is enab led.
Current operating mode (a uto / manual ). In
Auto mode, the program’s associated setpoint icon is
also displayed ( ).
Indicates the room OR floor temperature.
Heating indicators (see “Temperature Control”
below).
DVTH1 32-A
This model h as been desi gned to control a room’s ambi-
ent temperature.
The DVT H 132-A has one temperature sensor lo ca ted
in the control module.
DVTH1 32-AF
This model is design ed to use a floor sensor to co ntrol the
room tempe rature.
The DVTH132-AF has two temperature sensors:
• The first one, inst alled in the control module, controls
the a mbient temperature.
• The seco nd one , inst alled in the fl oor (and connected
to the power b a se), limits the temperature of the floor
(the default settin g of
this limit is 28°C).
DVTH1 32-F
This model is designed to co ntrol floor hea ting systems.
The DVT H132-F ha s one temperature sensor inst alled
in the floor (sensor is connected to the powe r base).
DVTH 132 has two switche s, located on the upper-left
part on the rea r of the control module, which are used to
set the fo llowing options:
Early Start
When th e Early Start function is en able d (disabled by
default), DVTH132 calculates the optimum system start
time to obtain the d esired temperature by the se t time. To
enable this function:
Po si tion switch #1 down .
Note: Whe n this function is enabled, the
system can be activated before the pro-
gram’s start time.
Tempera tur e Dis play
By de fault, DVT H132 displa ys the temperature in ° C. If
you wish to change to °F:
Po si tion switch #2 up.
Note: When you switch from °C to °F or vice
versa , the , a nd setpoi nts must be
redefined.
Control Module
DVTH132 A/F/AF
Owner’s Guide
DVTH132 Description
Models Overview
Configure the Switches
Align the b racket t abs o n the control module with th e
holes loca ted on top of the po wer base.
T his co ntrol module must be i nsta lled on a PB1 30 series
power bas e.
Note: Keep the thermostat's air vent s clean and free from
obstructions.
Note: The screw cannot be removed completely .
On the first installation, the screen displays:
0:00 , MO, an d temperature (room/flo or).
For Fl oo r He at ing Installation s:
One of the two following messages may be dis-
played when a probl em occurs:
LO : T he fl oor te mperature is belo w 0°C, or
the temperature sens or is de fective, or not
connected.
T he hea ting indicator is displaye d a nd
the rela y is close d (e nergized).
HI: T he fl oor temperature is abo ve
60°C , or the temperature sensor is
defective.
Set t he time (HOUR - MI N) .
Set the day (DAY ).
If you remove the module from it s base for more than
2 hours, the time and day will have to be reprogramme d.
Comfort and Econo my Set point s
Th ese setp oints are associat ed with the schedule’s pro-
grams (prog. 1 & 3 = Comfort, prog . 2 & 4 = Economy)
and are preprogrammed as fol lows:
A & AF mode ls— 20°C, 18°C
F mode l— 28°C, 20°C
To modify a set point:
Set the temperature using and press and hold the
or button until it is displ ayed on the screen .
Press MODE/RETURN to exit.
Vacat ion Set point
Th e va ca tion se tpoint is asso ciated to the V acation ope r-
ating mode an d is preprogrammed to 10 °C. T o modify this
setpoint, repeat above step s.
Floo r Temp erat ure Se tpoin t (AF mode l on ly )
Th e floor te mperature limit is p reprogra mmed to 28 ° C to
avoid damage to your floor.
To modify, press the a djustment button (bel ow ) using a
pointed obj ect, set the de si red temperature using and
press MODE/RETURN to exit.
DVT H 132 o ffers three operating mod es:
Au to ma tic —Exe cutes the sche dule.
P ress MO DE to select . T he c urrent
program number is displaye d.
You can temporarily byp ass th e current
program b y settin g a specific temperature setpoin t
or by sele cting one of the pre-defin ed setpoin t
buttons ( ). Th e new se tpoint will be maint ained
until the beginning of the next program.
Manual —Maintains a constant te mperature.
P ress MO DE to select .
Se t tempera ture or select one of the pre-
defined se tpoint buttons ( ).
Vaca tion —Maintains the V acation setpoint
during a p rolonged ab sence.
Pr es s .
Install the Control Module
Power base
Control module
Air vent s
Air vent s
First Power ON
Set the Time and Day
Adjust the Temperature Setpoints
Select the Operating Mode
DVK 132-00 0-A

T he s che dule is us ed with the A utoma tic mode . T he
schedule controls the heating sys tem to automatically
s witch between the C omfort and E conomy tempera ture
setpoints a t the times you have programmed.
T he schedule cons ists of 4 progra ms per day defined as
follows:
To enter the programs ’ s tart time
To shorten programming, you simply have to enter the
start time for each progra m.
P res s P G M.
P res s D AY to s elect the day (hold for 3 s econds to
select all days of the week).
Note: It is sometimes fas ter to program the s ame sched-
ule for the entire week a nd then to modify the exception
days .
P res s P G M to s elect the progra m number ( e.g. 1).
P res s HOUR and MIN to s et the s tart time.
R epeat steps 3 to 4 for remaining programs (e.g. 2, 3
and 4).
P res s MO DE /R E T UR N to exit.
Note: After 60 seconds of inactivity, the thermos tat will
automatically exit programming mode.
To c lear a program time:
When you clea r a program time entry, the T H132 will
maintain the temperature s etpoint of the las t executed
program until the beginning of the next program.
R epea t s teps 1 to 3 a bove.
P res s C L E AR to eras e the time e ntry. T he time por-
tion of the L C D indicates --:-- when the progra m is
inactive.
P res s MO DE /R E T UR N to exit.
P rogra mming E x ample
C omfort :
• Monda y to F riday, be twe en 6:00 and 8:30 a nd
between 16:00 and 23:00.
• S aturday and S unday, between 6:00 and 23:00.
E conomy :
• Monda y to F riday, be twe en 8:30 a nd 16:00 a nd
between 23:00 and 6:00.
• S aturday and S unday, between 23:00 a nd 6:00.
To program this s c hedule
P res s P G M.
P res s and hold D AY for 3 s ec onds to s elect all days
of the week.
P res s P G M to s elect program 1.
S et the time (6:00) us ing the HOUR and MIN buttons.
P res s P G M to s elect progra m 2.
S et the time (8:30) us ing the HO UR and MIN buttons.
R epea t step 4 for remaining programs :
program 3 (16:00) and program 4 (23:00).
When all programs are configured, press MO DE /
R E T UR N to exit.
To eras e programs 2 & 3 for S a turday and
S unday
P res s P G M.
P res s P G M to s elect progra m 2.
P res s DAY to select S Aturday (S A).
P res s C L E AR to eras e the time ( --:--).
P res s D AY to s elect S Unda y (S U ).
P res s C L E AR to eras e the time ( --:--).
P res s P G M to s elect progra m 3.
R epea t s teps 3 to 6.
P res s MODE /R E TUR N to exit.
P rogr am s S e tpoin t Time i
i. T he progra ms ’ start time ca n be different for each day of the week.
Wa ke-up
Leave home
B a ck home
Night
Program Your Schedule
P rograms MO TU WE T H F R S A S U
6:00 6:00 6:00 6:00 6:00 6:00 6:00
8:30 8:30 8:30 8:30 8:30 --:-- --:--
16:00 16:00 16:00 16:00 16: 00 --: -- --:--
23:00 23:00 23:00 23:00 23: 00 23:00 23:00
Temperature Control
DVTH132 thermos tat works differently than conventional
electromechanical thermos tats.
It is equipped with a proportional integral adaptive (P IA)
controller which determines heating cycles by analyzing
the temperature behavior history within the room.
The P IA controller reduces temperature swings providing
accurate temperature control while increasing us er com-
fort.
The controller determines the amount of power required
by the heating sys tem to maintain the setpoint tempera-
ture.
When the heating sys tem is activated, one of the following
icons is displayed:
Technical Specifications
Model : DVT H132 A / AF / F
Dis play r an ge: 32°F to 140° F (0° C to 60°C )
S ettin g r a nge(ambient): 40°F to 86°F (5°C to 30°C )
S ettin g r ange
(floor): 40°F to 104°F (5°C to 40°C )
P re-programmed tempe ra ture setpo ints :
C omfo rt: A/AF : 68 °F (20° C ) a nd F : 82° F (28° C )
E conomy: A/AF : 64°F (18° C ) a nd F : 68° F (20° C )
Vac ation: A/F /A F : 5 0°F (10 °C )
F lo or lim it: AF : 82°F (28°C )
Temperature resolution dis play s c ale:0.1°
S torage: -4° F to 120° F (-20°C to 5 0°C )
S oftware: C las s A
C ontrolle r: E lectronic
Temperature c ontrol: P roportional integra l adaptive ,
15-minute heating cycles
P rogramming pr otec tion: P rotected memory
C lo ck protec tio n: 2 hours
S ize (H/W/D): 3.3 x 3.1 x 0.5 in (83 x 79 x 13 mm)
Warranty
HandyHeat T WO Y E A R L I MI T E D WA R R AN T Y
This product is guaranteed against workmans hip defects
for a two-year period following the initial date of purchase.
During this period H andyHea t,. w ill re pa ir or
replace, at our option and without charge, any defective
product which has been us ed under normal conditions.
The warranty does not cover delivery cos ts and does not
apply to products poorly installed or randomly damaged
following ins tallation.
This warranty cancels and replaces any other
manufacturer's express or implied warranty as well as any
other company commitment HandyHeat
cannot be held liable for related or random damages
following the ins tallation of this product.
The defective product as well as the purchase invoice
must be returned to the place of purchas e or mailed,
prepaid and ins ured, to the neares t shipping a ddress .
If you ha ve any ques tions concerning the programming of
DVTH132 prog rammable thermos tat , call our technical
support team at:
1 to 20% 21 to 40% 41 to 60% 61 to 80% 81 to 100%
26/08/2003 400-132-000-A
Ndr. Fabriksvej 5
DK-8722 Hedensted
Denmark
Tel. +45 7675 8030
Fax +45 7675 8032
Email: [email protected]
www.handy-heat.com

-
Material
One (1) PB130 -230 po wer base
One (1) floor sensor (for floor h eating control mod ules AF
and F )
One (1) wall plate (optional, in cert ain countries)
Power Base
PB130-230
Installation Instructions
Technical Specifications
Model : PB1 30-23 0
Supply : 23 0 VAC , 50 Hz
Lo ad: 16 A maxi mum (resistive onl y)
Power : 3680 W atts (NI) @ 230 VAC
C erti fica tio n: E N607 30-2-9 / EN5 008 1-1 / EN50 082-2
St orage: -20°C to 50°C
Protect ion: C lass 2
Pr otec tion de gree:IP20
Automatic action : Type 1. B
Environment : Normally polluted
Size (H • W • D) : 75 x 75 x 14 mm (7 .5 x 7.5 x 1.4 cm)
NO TE: T he termin als are designed to handle a wire size
between 0.33 to 3.1 mm2.
TWO (2) YEAR LIMITED WARRANTY
This produ ct is guaranteed ag ainst workmans hip defects for a two -ye ar period following
the ini tial date o f purchase. During this period, HandyHeat . will re pair o r
replace, a t our option and without char ge, any def ective p roduct which has been us ed
under normal conditions.
The warranty does not cover delivery co sts and does n ot apply to products poorly
installed o r randomly damaged f ollowing installa tion. This warranty cancels and
replaces any ot her manu facturer's e xpress or implied warranty as well as any other
company c ommitment.
HandyHeat cannot be held liable for related or rand om dama ges f ollowing
the installation of this prod uct. The defective p roduct as well as t he p urchase invoice
must be r eturned to the p lace o f p urchase or ma iled, prepaid and insure d, to the
nea rest locat ion.
If you have any questions concerning the inst allation of the
PB130-230 power base , call our techn ical support team at:
Introduction
T he PB130-230 p ower base is desi gned to power aDVT H13 x
Series con trol mo dule. The resistive load must not exceed
3680 watts (NI) @ 230 VAC (16 A).
Installation Guidelines
Tu rn off power to the heating system at the main power pa ne l
to avoid e le c trical shoc k. Installa ti on s h o u ld be ca r rie d out by
a n elec tr ic ia n.
All work must conform to the most recent country’ s regu la-
tions for electrical inst allations an d wiring.
Th is thermost at should be connected on a circuit equ ipped
with a fuse or a circuit breaker . It must be installed on a certi-
fied el ectrica l box.
Fo r a new inst alla tion, choo se a lo cation about 1.5 m (5 ft.)
above th e floor.
The thermost at must be installed facing the heating system.
The thermostat must be installed on an inside wall.
Avoid locations where there are air dra fts (top of stairca se, air
outlet), dead air spo ts (b ehind a door), d irect sunl ight or con-
cealed chimne ys or stove pipe s.
Remove the scre w holding the con-
trol module to the power base.
Note that the scre w can not be
completely re moved.
If yo u have a wall plate : Before making
the co nnections, make sure that the base
covers t he ele ctrical box entirely. If n ot,
inse rt the cover pl ate on rear of the base.
NOTE: T he cover plate can be used to cover
the pla te for aesthetics.
Connect the wires:
•Power :
Terminals 1 and 5
•Lo ad:
Terminals 2 and 4
•F loo r sensor :
Terminals 6 and 7
(no pola rity needs
to be respected )
Do n ot pla ce the floor sensor
directly next to an element but
rather, for maximum
performance, the floor sensor should be ce ntered be tween the wire s
in the mat (80°C max.). The tem pera ture sensor wire ca nnot la y
across any heater wires.
If the lo ad is driven thro ugh a
contactor, a snubber must be inst alled
at the con tactor’s co il termina l. See
wiring dia gram below.
Push wires into th e electrical box an d secure
the base to the electrical box anchora ge.
Th e head of the screw must be less
than 2mm th ick.
Con figure the switches (if neces-
sary) a nd install the co ntrol mod-
ule o nto the power base (r efer to
the user gu id e).
Return power to the heating system .
DVK-130 -001 -A