manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Hanna Instruments
  6. •
  7. Chemical Test
  8. •
  9. Hanna Instruments HI 38042 User manual

Hanna Instruments HI 38042 User manual

Other Hanna Instruments Chemical Test manuals

Hanna Instruments HI 38067 User manual

Hanna Instruments

Hanna Instruments HI 38067 User manual

Hanna Instruments HI 38066 User manual

Hanna Instruments

Hanna Instruments HI 38066 User manual

Hanna Instruments HI 38051 User manual

Hanna Instruments

Hanna Instruments HI 38051 User manual

Hanna Instruments HI 3873 User manual

Hanna Instruments

Hanna Instruments HI 3873 User manual

Hanna Instruments HI 3832 User manual

Hanna Instruments

Hanna Instruments HI 3832 User manual

Hanna Instruments HI 38061 User manual

Hanna Instruments

Hanna Instruments HI 38061 User manual

Hanna Instruments HI 3826 User manual

Hanna Instruments

Hanna Instruments HI 3826 User manual

Hanna Instruments HI 3851 User manual

Hanna Instruments

Hanna Instruments HI 3851 User manual

Hanna Instruments HI 3822 User manual

Hanna Instruments

Hanna Instruments HI 3822 User manual

Hanna Instruments HI 38013 User manual

Hanna Instruments

Hanna Instruments HI 38013 User manual

Hanna Instruments HI 3824 User manual

Hanna Instruments

Hanna Instruments HI 3824 User manual

Hanna Instruments HI 3847 User manual

Hanna Instruments

Hanna Instruments HI 3847 User manual

Hanna Instruments DiST 2 User manual

Hanna Instruments

Hanna Instruments DiST 2 User manual

Hanna Instruments HI 713 User manual

Hanna Instruments

Hanna Instruments HI 713 User manual

Hanna Instruments HI 3835 User manual

Hanna Instruments

Hanna Instruments HI 3835 User manual

Hanna Instruments HI 3834 User manual

Hanna Instruments

Hanna Instruments HI 3834 User manual

Hanna Instruments HI 3896 User manual

Hanna Instruments

Hanna Instruments HI 3896 User manual

Hanna Instruments HI 98103 User manual

Hanna Instruments

Hanna Instruments HI 98103 User manual

Hanna Instruments HI 3864 User manual

Hanna Instruments

Hanna Instruments HI 3864 User manual

Hanna Instruments GroLine HI98331 User manual

Hanna Instruments

Hanna Instruments GroLine HI98331 User manual

Hanna Instruments HI 38015 User manual

Hanna Instruments

Hanna Instruments HI 38015 User manual

Hanna Instruments HI 3857 User manual

Hanna Instruments

Hanna Instruments HI 3857 User manual

Hanna Instruments HI 3838 User manual

Hanna Instruments

Hanna Instruments HI 3838 User manual

Hanna Instruments HI 3846 User manual

Hanna Instruments

Hanna Instruments HI 3846 User manual

Popular Chemical Test manuals by other brands

JBL PRO AQUATEST pH 7.4-9.0 INFORMATION FOR USE

JBL

JBL PRO AQUATEST pH 7.4-9.0 INFORMATION FOR USE

INDICAID 2120100 quick start guide

INDICAID

INDICAID 2120100 quick start guide

Elitech ENVOY 500 HDL manual

Elitech

Elitech ENVOY 500 HDL manual

LaMotte WaterLink Spin Touch quick start guide

LaMotte

LaMotte WaterLink Spin Touch quick start guide

JBL PRO AQUATEST O2 INFORMATION FOR USE

JBL

JBL PRO AQUATEST O2 INFORMATION FOR USE

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Instruction Manual
www.hannainst.com
DearCustomer,
Thank you for choosing a Hanna Product.
Please read the instruction sheet carefully before using the
test kit. It will provide you with the necessary information
for correct use of the kit. If you need additional information,
do not hesitate to e-mail us at [email protected].
Remove the chemical test kit from the packing material and
examine it carefully to make sure that no damage has
occurred during shipping. If there is any noticeable dam-
age, notify your Dealer or the nearest Hanna office
immediately.
Each kit is supplied with:
•HI93709A-0CitrateBufferReagent,packets(100pcs);
•HI93709B-0SodiumPeriodate Reagent, packets (100
pcs);
• 1 checker disc (containing a mirror, a mirror holder
and the 38072 disc);
• 2 glass vials with caps;
•1 plastic pipette (3 mL).
Note: Any damaged or defective item must be returned in
its original packing materials.
HI 38042
Manganese
Low Range
Test Kit
ISTR38042 10/00 PRINTED IN ITALY
Manganese is not present in natural waters but it is found
in various salts and minerals, frequently associated with
iron compounds. Manganese salts are used as fertilizer
additives, in ferroalloys (in steel manufacture), in non-
ferrous alloys as it improves their corrosion resistance and
hardness.
Manganese is not considered to be toxic to man and
aquatic life and it is ingested as a trace nutrient, both in
food and water. Nonetheless manganese has been limited
in drinking water since it causes tenacious stains to laundry
and because it produces objectionable tastes in beverages.
Manganese is commonly found in domestic wastewater,
industrial effluents and receiving streams.
Note: mg/L is equivalent to ppm (parts per million).
SPECIFICATIONSSPECIFICATIONS
SPECIFICATIONSSPECIFICATIONS
SPECIFICATIONS
SIGNIFICANCE AND USESIGNIFICANCE AND USE
SIGNIFICANCE AND USESIGNIFICANCE AND USE
SIGNIFICANCE AND USE
CHEMICAL REACTIONCHEMICAL REACTION
CHEMICAL REACTIONCHEMICAL REACTION
CHEMICAL REACTION
INSTRUCTIONSINSTRUCTIONS
INSTRUCTIONSINSTRUCTIONS
INSTRUCTIONS
The reaction between manganese and reagents causes a
violet tint in the sample which is proportional to the
manganese concentration.
READ THE ENTIRE INSTRUCTIONS BEFORE USING THE KIT
• Verify that the mirror, its holder and the disc are pre-
installed in the checker disc. If not, install them as
shown in the figure.
Range 0 to 3.0 mg/L (ppm) as Mn
SmallestIncrement 0.2 mg/L (ppm) Mn
AnalysisMethod Colorimetric
Sample Size 20 mL
Number of Tests 100
CaseDimensions 235x175x115 mm (9.2x6.9x4.5")
Shipping Weight 560 g (19.8 oz.) 20 mL
The chemicals contained in this kit may be hazardous if
improperly handled. Read the relevant Health and Safety
Data Sheet before performing this test.
HEALTH AND SAFETYHEALTH AND SAFETY
HEALTH AND SAFETYHEALTH AND SAFETY
HEALTH AND SAFETY
REFERENCESREFERENCES
REFERENCESREFERENCES
REFERENCES
Adaptation of the Periodate Oxidation Method, Standard
Methods for the Examination of Water and Wastewater,
18th edition.
• Usingthe plasticpipette,fill each glass
vial with 20 mL of sample (up to the
mark).
• Insert one of the vials into the left hand opening of the
checker disc. This is the blank.
• Add to the other
vial 1 packet of
HI 93709A-0 re-
agent.Replace the
cap and swirl to
mix.
• Remove the cap
and add 1 packet
ofHI93709B-0re-
agent. Replace the
cap and swirl to
mix.
• Wait for 1 minute and 30
seconds to allow reaction to
occur. This is the reacted
sample.
• Remove the cap and insert the reacted sample into the
right hand opening of the checker disc.
• Holdthechecker disc so that
alight sourceilluminatesthe
samples from the top.
• Keep the checker disc at a
distance of 30-40 cm (12-
16") to match the color.
Rotatethe discwhilelooking
at the color test windows and stop when you find the
color match. Read the value in the result window and
divide it by 3 to obtain mg/L (or ppm) of Manganese.
For best results: Perform the reading three times and take
the average value (divide by 3 the sum of the three
numbers).Intenselycolored sampleswillmakethecolor
matchingdifficult andthey shouldbeadequately treated
before performing the test. Suspended matter in large
amounts should be removed by prior filtration.
Caution: Ultraviolet radiation may cause fading of colors.
When not in use, keep the disc protected from light,
in a cool and dry place.
Interferences:Calcium above 700 ppm, magnesium above
100000 ppm, chloride above 7000 ppm, iron above
5 ppm.