Harbor Breeze 80206 User manual

42944-01 02/14/2008
1
Installation Guide
80206 Bath Ventilator with Light
READ and SAVE THESE INSTRUCTIONS
ENGLISH
See page 2
ESPAÑOL
Vea la página 41
FRANCAIS
Voir la page 21
42944-01_2-14-08_ARIAL.indd 1 2/14/08 4:02:29 PM

42944-01 02/14/2008
2
DISCONNECT ELECTRIC
POWER SUPPLY
AND LOCK OUT
SERVICE PANEL BEFORE
SERVICING UNIT
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. To avoid motor/blower bearing damage and noisy/unbalanced
impellers, keep drywall spray, construction dust, etc. off power unit.
3. DO NOT install this product in a wall. This product is designed
for installation in ceilings up to a 12/12 pitch (45 degrees).
Ductwork must point upward.
4. Pleasereadspecicationlabelonproductforfurtherinformation
and requirements.
PREVENTATIVE MAINTENANCE
A clean fan provides better service. Disconnect the power supply
and clean the fan as listed below.
TO CLEAN GRILLE: Use a mild detergent, such as dishwashing
liquid, and a soft cloth. DO NOT use abrasive cloths, steel wool
pads or scouring powders.
TO CLEAN FAN ASSEMBLY: Unplug motor/blower cord from recep-
tacle. To remove motor/blower, find the single tab on the motor/blower
(located next to the receptacle). Push up rear motor/blower tab while
pushing out on the side of the housing or insert a screwdriver into the
slot in the housing (next to tab) and twist screwdriver. Gently vacuum
fan, motor/blower and interior of housing.
METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED
IN WATER.
MAINTENANCE
The motor/blower is permanently lubricated and never needs oiling.
If the motor/blower bearings are making excessive or unusual noises,
replace the motor/blower with the exact service motor/blower. You
should replace the impeller at the same time.
CAUTION WARNING
1. Use this unit only in a manner intended by the manufacturer.
If you have questions, contact the manufacturer.
2. Before servicing or cleaning the unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by
qualiedperson(s)inaccordancewithallapplicable
codesandstandards,includingre-ratedconstruction.
4. Sufcientairisneededforpropercombustionandexhausting
ofgassesthroughtheue(chimney)offuelburningequipment
to prevent backdrafting. Follow the heating equipment manufac-
turer’s guideline and safety standards,such as those published
by the National Fire Prevention Association (NFPA), and the
American Society for Heating, Refrigeration and Air-Conditioning
Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall(s) or ceiling, do not damage
electrical wiring or other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected to a
GFCI (Ground Fault Circuit Interrupter) – protected branch circuit.
8. Never place a switch where it can be reached from a tub or
shower.
9. Installfanatleast5feet(1.52m)abovetheoor.
10. This unit must be grounded.
11. Unit must not be installed in a ceiling thermally insulated to a
value greater than R40.
Do Not Install Above
Or Inside This Area
Cooking
Equipment
Floor
45° 45°
COOKING AREA
42944-01_2-14-08_ARIAL.indd 2 2/14/08 4:02:29 PM

42944-01 02/14/2008
3
D
E
F
G
H
I
95044-01-000
95022-01-000
75190-01-000
03242-07-133
95492-01-000
L
95510-01-000
N
95020-02
M
75184-01-133
x5
*
*
*
NOTE:
Strain relief cable
connector must be
installed. Not Included.
A
B
C
Extra Screws
x2
I
3/8 in. Cable Connector
x2
74508-03-133 Motor/Blower
Screws
Light Fixture
J
77520-01
Strain Relief Bracket
K
65219 Strain Relief Bracket Screw
Thumbscrews
Glass Dome
Mounting Rails
Housing
Wiring Cover
Wiring Cover Screw
OFF
3
0
OFF
30
OFF
20
30
OFF
30
OFF
30
2
1
2
E
I
Turn off the power source.
Tools Needed. (Not supplied)
Estimated assembly time: 30 to 60 minutes
Before Installation
Check all the parts.
If damaged, call
1-866-405-3814
for replacements.
Included.
Loosen screws.
NOTE: Remove all packing materials before installation.
42944-01_2-14-08_ARIAL.indd 3 2/14/08 4:02:30 PM

42944-01 02/14/2008
4
5
7
G
8
F
H
E
3
6
4
Remove the motor/blower from the housing.
Remove the pre-loaded screw tip covers.
Remove the wiring cover screw.
Back out the pre-loaded screw tips until flush
with the side of the housing.
Remove the wiring cover.
Remove packing material.
42944-01_2-14-08_ARIAL.indd 4 2/14/08 4:02:33 PM

42944-01 02/14/2008
5
E
9
B
C
10
E
A1
5/8
1/2
5/8
1/2
A2
Pop out the first wiring access slug. Use second if needed. Insert the strain relief into the housing and
secure with the washer.
Position the correct depth mark at the bottom edge of the
joist based on the thickness of your sheetrock.
New Construction – attaching to joist
Choose Installation Option
For New Construction - attaching to joist go to step A1, page 5
For New Construction - suspended between joists go to step B1, page 8
For Existing Construction - accessible from above go to step C1, page 11
For Existing Construction - accessible only from below go to step D1, page 15
Screw pre-loaded screws into joist or framing.
42944-01_2-14-08_ARIAL.indd 5 2/14/08 4:02:36 PM
Table of contents
Popular Ventilation Hood manuals by other brands

Gorenje
Gorenje S3 IHGC963S4X manual

KOBE
KOBE ISX2136SQB-1 Installation instructions and operation manual

U.S. Products
U.S. Products ADVANTAGE-100H Information & operating instructions

Kuppersberg
Kuppersberg DUDL 4 LX Technical Passport

Framtid
Framtid HW280 manual

Thermador
Thermador HGEW 36 FS installation manual