HARVEY RC4 User manual

RC4: IP-based remote control for audio,
lighting and media technology
Operating Manual
www.harvey.audio
Version 1.0

Operating Manual HARVEY RC4
2/20
ÓDSPECIALISTS GmbH, Berlin

Operating Manual HARVEY RC4
4/20
1 Introduction
HARVEY RC4 is a freely programmable end-user wall remote control for Ethernet networks.
It is compatible to all members of the HARVEY family of audio and media control matrixes.
The remote control is supplied exclusively via Ethernet (PoE).
For user interaction the HARVEY RC4 has one rotary encoder with an integrated push button
and four LED backlit push buttons to control audio levels, invoke DMX commands, or recall
scene settings. The four push buttons can be labelled. A LED light ring indicates fader
positions. All LEDs are of RGB type and can be programmed with an individual colour
scheme and brightness. HARVEY RC4 is completely supported by HARVEY Composer
allowing a seamless configuration of complex media scenarios where several remotes in
parallel control a system of HARVEY audio matrixes.
Two HARVEY RC4 models exist:
1. HARVEY RC4-EU: RC4 in a plastic housing compatible for mounting into standard
round European flush-mounted boxes with a diameter of 60 mm.
2. HARVEY RC4-US: RC4 with a metal faceplate compatible for mounting into standard
2-gang North-American flush-mounted boxes.
This manual shows how to wire, assemble and label both the HARVEY RC4-EU and the
HARVEY RC4-US model.
For programming and integration into your audio or control projects please refer to the
HARVEY Composer manual.

Operating Manual HARVEY RC4
5/20
2 Overview HARVEY RC4-EU

Operating Manual HARVEY RC4
6/20
RC4-EU Specifications
Push buttons 4x with integrated RGB LED; brightness and colour freely
definable in HARVEY Composer; foil labels can be inserted for
push button labelling; functions programmable in HARVEY
Composer: preset call, logic control
Rotary Knob Endless rotary encoder with integrated push button; functions
programmable in HARVEY Composer: audio level, mute control,
DMX control
LED Ring 10x RGB LED; display fader position, mute status for level control
and device status
Data Link 10/100 Mbps Ethernet (100BaseT); standard IP protocol
Ethernet Cable
Interface
Two connector options on rear side:
a. RJ45 with activity/link/speed LED for standard network cable
(e.g. CAT5)
b. 4-pole terminal block with compression contacts for heavy and
stiff S/FTP cable (e.g. most CAT7); external cable clamp for
shield and strain relief
Power Supply PoE IEEE802.3af Class 3 (12,95 W)
Actual power consumption:
- nom. <5 W with all LEDs switched on at normal brightness
- max. 10 W with all LEDs switched on at maximum brightness
RJ45 interface: PoE power provision from IEEE802.3af Ethernet
switches (endspan PoE) or alternatively PoE injectors (midspan
PoE).
4-pole terminal block: Only endspan PoE capable.
Mounting and
Housing
Two-piece plastic housing designed but not limited to be mounted
into one-gang EU flush-mounted boxes (60 mm diameter), onto
metal front panels (e.g. 19” racks) or into plated furniture (e.g.
conference room);
depth of housing’s rear side just 10 mm (without cables).
It is recommended a use a flush-mounted box with a depth of
60 mm to give the CAT cable enough space in the wall.
Quick two step mounting:
1) Attach cable from wall and mount wall panel with 2 screws
2) Snap and mount front part to wall panel with 1 screw
Dimensions 80 mm x 84 mm x 35 mm, weight 100 g / 0.2 lbs.
Colour White (RAL9003); other colours available on request

Operating Manual HARVEY RC4
7/20
3 Overview HARVEY RC4-US

Operating Manual HARVEY RC4
8/20
RC4-US Specifications
Push buttons 4x with integrated RGB LED; brightness and colour freely
definable in HARVEY Composer; foil labels can be inserted for
push button labelling; functions programmable in HARVEY
Composer: preset call, logic control
Rotary Knob Endless rotary encoder with integrated push button; functions
programmable in HARVEY Composer: audio level, mute control,
DMX control
LED Ring 10x RGB LED; display fader position, mute status for level control
and device status
Data Link 10/100 Mbps Ethernet (100BaseT); standard IP protocol
Ethernet Cable
Interface
RJ45 with activity/link/speed LED for standard network cable (e.g.
CAT5)
Power Supply PoE IEEE802.3af Class 3 (12,95 W)
Actual power consumption:
- nom. <5 W with all LEDs switched on at normal brightness
- max. 10 W with all LEDs switched on at maximum brightness
RJ45 interface: PoE power provision from IEEE802.3af Ethernet
switches (endspan PoE) or alternatively PoE injectors (midspan
PoE).
Mounting and
Housing
Aluminium front panel designed but not limited to be mounted
onto two-gang US flush-mounted boxes.
Distance of mounting holes: 1.8125” / 46 mm X 3.281” / 83.3 mm
It is recommended a use a flush-mounted box with a depth of
60 mm to give the CAT cable enough space in the wall.
Dimensions Shape of aluminium front panel and electronics:
110 mm x 110 mm x 28 mm, weight 100 g / 0.2 lbs.
Colour Aluminium anodized; other colours available on request

Operating Manual HARVEY RC4
9/20
4 Quick Installation
For full HARVEY RC4 configuration and operation following items are required:
1. Minimum one HARVEY RC4,
2. HARVEY Composer (v2.1.4.0 onwards) installed on a Windows computer,
3. Either
a. an Ethernet switch capable of delivering Power over Ethernet (PoE) according
to IEEE802.3af Class 3 (12.95 W) or
b. a regular (non-PoE) Ethernet switch in combination with an Ethernet PoE-
Injector which is capable of delivering PoE according to IEEE802.3af Class 3
(12.95 W),
4. a HARVEY audio matrix (any HARVEY NxM model).
Wiring
The following three diagrams show all wiring options for HARVEY RC4.
Option 1 – Flexible network cable with power provision from a switch with PoE capability
attached to the RJ45 connector of the RC4.
Option 2 – Flexible network cable with standard Ethernet switch without PoE capability and
power provision from a PoE Injector attached to the RJ45 connector of the RC4.
Option 3 – Stiff network cable with power provision from switch with PoE capability attached
to the terminal block of the RC4.This option does not apply to the RC4-US model.

Operating Manual HARVEY RC4
10/20
A switch-based power provision (i.e. endspan PoE) is possible both for RJ45 wiring option 1
and for the terminal block wiring option 3.
An injector-based power provision (i.e. midspan PoE) is possible for the RJ45 wiring option 2
only.
Stiff Network Cable (e.g. CAT7)
For stiff network cables the RC4 offers wiring option 3 – a connection to the internal 4-pole
terminal block which accepts stiff wires only. This option does not apply to the RC4-US
model. Following cable assignment is valid for the terminal block:
Status LED
As soon as the RC4 is powered and connected to the network it indicates its status by the
bottom LED of the light ring.
Yellow: RC4 is in self initialization mode1.Blue: RC4 has network link and waits for
pairing with a HARVEY device.
It leaves the before mentioned two states as soon it is actively paired with a HARVEY project
which has been programmed with HARVEY Composer. Please refer to the HARVEY
Composer operating manual for integrating HARVEY RC4 into your HARVEY projects.
1Among other things during initialization the RC4 waits for a physical network link. A physical link to
the Ethernet network and data activity are indicated at the RJ45 interface on the rear side of the RC4,
for both the RJ45 and terminal block wiring option.

Operating Manual HARVEY RC4
11/20
5 Instructions for Mounting, Labelling and Wiring
PROCEDURE 1: Follow these instructions forwards for disassembly in case you want to mount
a RC4 to a wall panel or you want to label the four push buttons. Assembly is done in the
reverse order.
For disassembly of the
RC4-EU housing first you
have to demount the rotary
knob.
For this you need a hexagonal
screwdriver (1.3 mm), which is
delivered together with the
RC4.
Insert the screwdriver into the side hole of
the rotary knob. Find the screw and unscrew
it just one to two turns to avoid losing the little
grub screw.
Pull the button off the endless encoder shaft.
It needs some force – be patient, wobble the
knob a little bit, then it can be removed.
continues on next page…

Operating Manual HARVEY RC4
12/20
…continuation of PROCEDURE 1 (disassembly of upper and lower housing shells):
Use a cross-headed screwdriver to remove
the screw next to the encoder shaft which
joins the upper and lower housing shell.
Divide the upper and lower shell of the RC4
housing.
Finish of PROCEDURE 1 (disassembly of upper and lower housing shells).
For labelling the four push buttons proceed with PROCEDURE 2 on the next page.
For mounting the RC4 onto an EU flush-mounted box (UP60) and a flexible network cable
with a RJ45 connector follow PROCEDURE 3.
For attaching the RC4 to a stiff network cable coming from the wall follow PROCEDURE 4 first
and then proceed with the second half of PROCEDURE 3 for flush-mounted box mounting.

Operating Manual HARVEY RC4
13/20
PROCEDURE 2: Proceed with the following steps for labelling the four push buttons of the
RC4.
Remove the screw joining the printed circuit
board and the front shell of the housing.
Remove the front shell from the printed
circuit board.
Remove the light guide bodies by gently
pulling them from the push buttons.
Remove the transparent caps from the light
guide bodies.
continues on next page…

Operating Manual HARVEY RC4
14/20
…continuation of PROCEDURE 2 (labelling push buttons):
Good results can be achieved by printing the
labels on transparent foil sheets and cutting
them with a knife or scissors.
Put the label into the transparent cap and the
cap onto the light guide body.
Gently put the light guide bodies back onto the
push buttons.
Finish of PROCEDURE 2 (labelling push buttons).

Operating Manual HARVEY RC4
15/20
PROCEDURE 3: Mounting onto an EU flush-mounted box and connecting a flexible network
cable coming from the all to the RJ45 connector.
The RC4 is designed for mounting into a
standard 60 mm European flush-mounted box
(UP60).
A box’s depth of 60 mm is recommended.
Take the lower shell, insert the network cable
through the RJ45 opening and mount that
configuration onto the flush-mounted box.
Plug the RJ45 connector into the RJ45 on the
upper shell’s side.
continues on next page…

Operating Manual HARVEY RC4
16/20
…continuation of PROCEDURE 3 (wall mounting with flexible network cable with RJ45):
Put the left side of the upper shell’s slots over
the two keys of the lower shell.
Proceed with the instructions of Procedure 1 in
reverse order to re-assemble the housing.
Finish of PROCEDURE 3 (wall mounting with RJ45).

Operating Manual HARVEY RC4
17/20
PROCEDURE 4: Connecting a stiff network cable without RJ45 coming from the wall to the
terminal block connector.
Strip off appr. 50 mm of the stiff network
cable’s mantle.
This is the result of de-mantling the cable.
Gently divide the four wire pairs with their
shield foil.
continues on next page…

Operating Manual HARVEY RC4
18/20
…continuation of PROCEDURE 4 (wall mounting with stiff network cable without RJ45):
Cut the foils – do not cut the shield-mesh!
Turn back the shield-mesh and wind it
around the end of the four wire pairs.
Cut those four wires which are not required
for a 100BaseT wiring (i.e. wires 4, 5, 7 and 8
according to the standard T-568A/B
numbering rules) – only following wires are
required:
Wire 1: Tx+ / DA+
Wire 2: Tx- / DA-
Wire 3: Rx+ / DB+
Wire 6: Rx- / DB-
Wire pairs 1 / 2 and 3 / 6 should be twisted.
Lead the stiff wires from the rear side of the
lower housing shell through the designated
whole.
Use a long-nosed plier to lead each stiff wire
into the correct terminal during gently
pushing down the referring white window with
a screw driver.
continues on next page…

Operating Manual HARVEY RC4
19/20
…continuation of PROCEDURE 4 (wall mounting with stiff network cable without RJ45):
This is the result of the cable installation to the
terminal block.
On the rear side of the lower shell push the
shield-mesh of the stiff network cable under the
cable clamp and fasten the screw tightly.
Put the left side of the upper shell’s slots over the
two keys of the lower shell.
Proceed with the instructions of Procedure 1 in
reverse order to re-assemble the housing.
Finish of PROCEDURE 4 (connecting stiff network cable to terminal block).

Operating Manual HARVEY RC4
CONTACT
DSPECIALISTS
Digitale Audio- und Messsysteme GmbH
Helmholtzstr. 2-9L
10587 Berlin
Germany
Phone +49 30 467 805-0
Fax +49 30 567 805-99
www.dspecialists.de
www.harvey.audio
This manual suits for next models
2
Table of contents