Hausted ViC329 User manual

GF HEALTH PRODUCTS, INC.
GFH1300117RevA13

WARNING
- COPYING PROHIBITED

i
GF Health Products, Inc.
for replacement
model number of Wey
accessories chairGF
will
We youGF Health Products, Inc.
with any mconcern
GF HEALTH PRODUCTS, INC.
3 GF Health Products, Incd
by
GF Health Products, Inc., could affectits
could violate
and could
GF HEALTH PRODUCTS, INC.

ii
EC Authorized Representative
GF Health Products, Inc.
336 Trowbridge Drive
Fond du Lac, WI 54937
678.291.3207
770.368.2386
Class 1 equipment
l

iii
e for the User.......

1-1
l
l
l
l
l
l
l
l
l
l
l
l
WARNING –NOTICE FOR
CALIFORNIA CUSTOMERS-
California Proposition 65 Warning: This
product contains a chemical known to the
State of California to cause cancer and
reproductive or developmental harm.

2-1
l
l
l
properly.
if any of the
properly, call
GF Health Products, Inc.678.291.3165

3-1
l
intended to replace a
warning label on
stating:

3-2

3-3
l
l

l

l

l

l

l
l

l

l

Secondary Patient Device
VIC Chair
Patient Preparation
Secondary Device Preparation
VIC Chair Preparation
l

Patient Transfer

PREVENTIVE MAINTENANCE FOR THE USER 4
Component Cleaning Procedure Schedule Cleaning Agent * Special Notes
Pads/Mattresses Wipe with damp cloth to
remove any foreign material
After each
use
Routine hospital grade
disinfectants, soap and
water
Use only medium
strength cleaners
Do not steam clean or
pressure wash
Chair Wipe with damp cloth to
remove any foreign material
After each
use
Routine hospital grade
disenfectants, soap and
water
Lubricate pivot points
after cleaning
Electrical
components
Wipe external surfaces ONLY
with damp cloth to remove
any foreign material
After each
use
Routine hospital grade
disinfectants, soap and
water
Use only medium
strength cleaners
Mechanical
chair
components
Wipe with damp cloth to
remove any foreign material
After each
use
Routine hospital grade
disinfectants, soap and
water
Lubricate pivot points
after cleaning
Mechanical
accessories
Wipe with damp cloth to
remove any foreign material
After each
use
Routine hospital grade
disinfectants, soap and
water
Lubricate pivot points
after cleaning
Procedure Schedule Material
Lubricate all moving and sliding parts and hinge
points
Every 3
months
Lubricating oil, light-duty grease, wax stick
lubricant or Never-Seez lubricant
NEVER LUBRICATE GAS SPRING, MOTOR OR MECH-LOCK SHAFTS
Inspect all fasteners to ensure proper t,
position and tightness (including nuts, bolts,
etc.)
Every 3
months
Proper size wrench and screwdriver
Inspect all surfaces and remove any sharp
or burred areas; apply touch-up paint where
required
Every 3
months
Metal le, proper color paint (specify color when
ordering)
* Disinfectants, vinyl products: Phenolic disinfectants are the best choice for vinyl products; properly diluted
quaternaries are also acceptable. Quaternary/Isopropyl disinfectants are not recommended for vinyl.
Disinfectants, urethane products: Quaternary disinfectants are recommended for urethane products. Quaternary/
Isopropyl disinfectants are recommended for urethane. Phenolics should be avoided on urethane.
Disinfectants, all products: All fabrics may be cleaned with a 1:10 dilution of household bleaches containing
5.25% sodium hypochlorite as recommended by the Centers for Disease Control in Atlanta, Georgia. There is no
harmful effect on the fabric. Disinfectants applied at full concentration or in highly concentrated solutions will
decrease the useful life of fabric. Iodophor type disinfectants used on fabrics may result in staining.
Soils or Stains: Use neutral soap suds and lukewarm water. Do not use harsh cleansers, solvents or detergents.
Hard-To -Clean Spots: Use standard household/vinyl cleansers and a soft bristle brush on troublesome spots or
stains. Pre-soak heavy, dried-on soil.
Laundering Vinyl-laminated or Rubber-coated fabric is not recommended. Laundering may substantially
decrease the useful life of the fabric.
Laundering Polyurethane-coated fabric: Machine wash with detergent up to 120°F. Some surface wrinkling may
occur; this wrinkling has no adverse effect on the fabric properties. Hang or tumble dry thoroughly at 140° F
before storage.
CAUTION
- POSSIBLE EQUIPMENT DAMAGE HAZARD: Steam cleaning and
pressure washing of chair is not recommended and can void warranty.
NOTE: For more detailed information, please contact GF Health Products, Inc. at 678.291.3165.
NOTE: In addition to the User Preventive Maintenance, a more detailed Preventive Maintenance Program is also
required to keep the equipment in good working order. This Preventive Maintenance Program is found on our
website, at www.Hausted.com.
4-1
GFH1300117RevA13
This manual suits for next models
1
Table of contents
Popular Indoor Furnishing manuals by other brands

Euro-Rite Cabinets
Euro-Rite Cabinets Vanity 3 Drawer Bank Assembly instructions

Berlin Gardens
Berlin Gardens PZDC2127 Assembly Directions

faulkner
faulkner HW0929 Assembly instructions

VITRA
VITRA 1959/1999 Assembly instructions

Amart Furniture
Amart Furniture 59029 Assembly instruction

Thomasville
Thomasville Geneva 6278-544 Assembly instructions