hayneedle Belle Foret N180 01 User manual

installation
For Models: N180 01
Tools
Preparation/Assembly
1
2
3
Installation
Parts Breakdown
Maintenance
Satety Tips
Important Points
Things You May Need
Your new pot filler faucet is designed for years of trouble-free performance.
Keep it looking new by cleaning it periodically with a soft cloth. Avoid
abrasive cleaners, steel wool and harsh chemicals as these will dull the finish
and void your warranty.
• If you use soldering for the installation of the faucet, the seats, cartridges
and washers will have to be removed before using flame. Otherwise,
warranty will be void on these parts.
• Protect your eyes with safety glasses when cutting or soldering water
supply line.
• Cover your drain to avoid losing parts.
Prior to beginning installation, turn off the cold and hot water lines and open
the old faucet to release built-up pressure. When installing your new faucet,
turn the connector nuts finger-tight, then use one wrench to anchor the fitting
and a second wrench to tighten the nut one additional turn. Connections that
are too tight will reduce the integrity of the system. Wrap all threaded connections
with Teflon tape available at your local hardware or plumbing supply store.
Always wrap in a clockwise direction. The fittings should be installed by the
State-licensed plumber.
All installations can vary depending on how your previous faucet was installed.
Necessary supplies to install your faucet are not all included; however, they are
available wherever plumbing supplies are sold. When choosing your installation
supplies, make sure they are IAPMO and/or CSA approved products.
4
Steps 1-5 Parts Diagram
Shut off water supply before installation.
After the wall is finished, install the mounting bracket. Apply pipe tape to
the threads of stub-out pipe. Screw on the wall mount bracket clockwise.
RUN 1/2" IPS/NPT threaded stub out pipe through center of blocking
board; length of stub out to allow 1/2" to extend beyond the finished
wall surface.
6After installation, remove aerator and turn on water to remove any left
over debris. Reassemble aerator. This faucet is equipped with two valves,
the wall valve should be closed (handle in vertical position) when faucet
is not in use.
Before attaching the screws provided to the wood blocking, drill four holes
into wall materials by passing through the slots of bracket. Attach the
bracket with minimum 1 3/4" long screws through the wall surface and
into the wood blocking.
5A. Position the wall flange onto the shank of the wall valve body. (The
flange will not pass over the set screw if it projects out).
B. After sliding on the flange, unscrew the set screw so that the point
inside is flush with the body wall. (You can not install the body onto the
bracket if the set screw is in the way).
C. Press the valve body onto the bracket; take care that the swing arm is
level. Install the faucet by tightening the set screw at the bottom of body
clockwise with allen wrench supplied, then slide flange to the wall.
Mental handle assembly
Bracket assembly
Mental handle assembly
Canopy
Cartridge
Screw
O-ring
Gasket
O-ring
Wrench
Pipe tape
O-ring
Cap
Canopy
Aerator
O-ring adaptor
Flange

installation
For Models: N180 01
Tools
Preparation/Assembly
1
2
3
Installation
Parts Breakdown
Maintenance
Satety Tips
Important Points
Things You May Need
Your new pot filler faucet is designed for years of trouble-free performance.
Keep it looking new by cleaning it periodically with a soft cloth. Avoid
abrasive cleaners, steel wool and harsh chemicals as these will dull the finish
and void your warranty.
• If you use soldering for the installation of the faucet, the seats, cartridges
and washers will have to be removed before using flame. Otherwise,
warranty will be void on these parts.
• Protect your eyes with safety glasses when cutting or soldering water
supply line.
• Cover your drain to avoid losing parts.
Prior to beginning installation, turn off the cold and hot water lines and open
the old faucet to release built-up pressure. When installing your new faucet,
turn the connector nuts finger-tight, then use one wrench to anchor the fitting
and a second wrench to tighten the nut one additional turn. Connections that
are too tight will reduce the integrity of the system. Wrap all threaded connections
with Teflon tape available at your local hardware or plumbing supply store.
Always wrap in a clockwise direction. The fittings should be installed by the
State-licensed plumber.
All installations can vary depending on how your previous faucet was installed.
Necessary supplies to install your faucet are not all included; however, they are
available wherever plumbing supplies are sold. When choosing your installation
supplies, make sure they are IAPMO and/or CSA approved products.
4
Steps 1-5 Parts Diagram
Shut off water supply before installation.
After the wall is finished, install the mounting bracket. Apply pipe tape to
the threads of stub-out pipe. Screw on the wall mount bracket clockwise.
RUN 1/2" IPS/NPT threaded stub out pipe through center of blocking
board; length of stub out to allow 1/2" to extend beyond the finished
wall surface.
6After installation, remove aerator and turn on water to remove any left
over debris. Reassemble aerator. This faucet is equipped with two valves,
the wall valve should be closed (handle in vertical position) when faucet
is not in use.
Before attaching the screws provided to the wood blocking, drill four holes
into wall materials by passing through the slots of bracket. Attach the
bracket with minimum 1 3/4" long screws through the wall surface and
into the wood blocking.
5A. Position the wall flange onto the shank of the wall valve body. (The
flange will not pass over the set screw if it projects out).
B. After sliding on the flange, unscrew the set screw so that the point
inside is flush with the body wall. (You can not install the body onto the
bracket if the set screw is in the way).
C. Press the valve body onto the bracket; take care that the swing arm is
level. Install the faucet by tightening the set screw at the bottom of body
clockwise with allen wrench supplied, then slide flange to the wall.
Mental handle assembly
Bracket assembly
Mental handle assembly
Canopy
Cartridge
Screw
O-ring
Gasket
O-ring
Wrench
Pipe tape
O-ring
Cap
Canopy
Aerator
O-ring adaptor
Flange

installation
For Models: N180 01
Tools
Preparation/Assembly
1
2
3
Installation
Parts Breakdown
Maintenance
Satety Tips
Important Points
Things You May Need
Your new pot filler faucet is designed for years of trouble-free performance.
Keep it looking new by cleaning it periodically with a soft cloth. Avoid
abrasive cleaners, steel wool and harsh chemicals as these will dull the finish
and void your warranty.
• If you use soldering for the installation of the faucet, the seats, cartridges
and washers will have to be removed before using flame. Otherwise,
warranty will be void on these parts.
• Protect your eyes with safety glasses when cutting or soldering water
supply line.
• Cover your drain to avoid losing parts.
Prior to beginning installation, turn off the cold and hot water lines and open
the old faucet to release built-up pressure. When installing your new faucet,
turn the connector nuts finger-tight, then use one wrench to anchor the fitting
and a second wrench to tighten the nut one additional turn. Connections that
are too tight will reduce the integrity of the system. Wrap all threaded connections
with Teflon tape available at your local hardware or plumbing supply store.
Always wrap in a clockwise direction. The fittings should be installed by the
State-licensed plumber.
All installations can vary depending on how your previous faucet was installed.
Necessary supplies to install your faucet are not all included; however, they are
available wherever plumbing supplies are sold. When choosing your installation
supplies, make sure they are IAPMO and/or CSA approved products.
4
Steps 1-5 Parts Diagram
Shut off water supply before installation.
After the wall is finished, install the mounting bracket. Apply pipe tape to
the threads of stub-out pipe. Screw on the wall mount bracket clockwise.
RUN 1/2" IPS/NPT threaded stub out pipe through center of blocking
board; length of stub out to allow 1/2" to extend beyond the finished
wall surface.
6After installation, remove aerator and turn on water to remove any left
over debris. Reassemble aerator. This faucet is equipped with two valves,
the wall valve should be closed (handle in vertical position) when faucet
is not in use.
Before attaching the screws provided to the wood blocking, drill four holes
into wall materials by passing through the slots of bracket. Attach the
bracket with minimum 1 3/4" long screws through the wall surface and
into the wood blocking.
5A. Position the wall flange onto the shank of the wall valve body. (The
flange will not pass over the set screw if it projects out).
B. After sliding on the flange, unscrew the set screw so that the point
inside is flush with the body wall. (You can not install the body onto the
bracket if the set screw is in the way).
C. Press the valve body onto the bracket; take care that the swing arm is
level. Install the faucet by tightening the set screw at the bottom of body
clockwise with allen wrench supplied, then slide flange to the wall.
Mental handle assembly
Bracket assembly
Mental handle assembly
Canopy
Cartridge
Screw
O-ring
Gasket
O-ring
Wrench
Pipe tape
O-ring
Cap
Canopy
Aerator
O-ring adaptor
Flange
Table of contents
Popular Plumbing Product manuals by other brands

Axor
Axor ShowerSelect Round Installation/User Instructions/Warranty

Brizo
Brizo Trevi Cross 6216709 manual

Axor
Axor Starck FixFit Round 27451 Series Assembly instruction

Glacier bay
Glacier bay 67236-0A01 Installation and care guide

VOXORT
VOXORT PERLA BLACK V401140 Installation instruction

Waterworks
Waterworks HENRY HNLS20 manual

Hans Grohe
Hans Grohe AXOR Urquiola 11026000 Instructions for use/assembly instructions

CUR AQUA
CUR AQUA 431-107 operating instructions

Sanela
Sanela SLUN 62EB manual

Dolphin Solutions
Dolphin Solutions Dolphin Blue DB100 Series Installation and maintenance guide

Mira
Mira Flight Wall Installation and user guide

Harvia
Harvia SMARTFOLD SF1212R Instructions for installation and use