HESCablingSystem
Installation Manual for Category 6E Shielded Tool-Less Keystone Jack
HCS P/N J6E-00863 - Universal Wiring - FTP Cable
1Remove 5 cm of the cable jacket. 2Carefully remove the foil shield.
Make sure the drain wire remains intact.
3Hold the wiring block with the colored side up and insert the pairs into place as shown below.
4Insert the wires into the correct colored slots. 5Cut the wires flush with a sharp tool.
6Slide the wiring block into the the jack housing with the colored side down and
push gently with your thumb. Note the guide and the IDC contacts. 7 Fold up the side caps.
8Press the side caps firmly until they click and
make sure both caps are securely closed. 9Slide the metal shield over the
jack. Note the correct orientation. 10 Wrap the drain-wire around the
cable and close the metal shield.
11 Make sure the two grounding belts are
inserted into the two slots. 12 Pull the grounding belts with a
suitable pliers and fold them. 13 Wrap the ground wire and press
tightly both grounding belts.
Note: Avoid damaging the cable when using the pliers and make sure the drain wire is in good contact with the keystone jack shield.
Form HC6F-TLKSJ-1 Rev 02/05 dated 26 July 2005
www.hescs.com