Cleerline SSF Corning Unicam LC User manual

4. Cleave fiber to the appropriate
measurement. For the Corning type connector
this measurement = 20mm from the 2.0 or
3.0mm jacket to fiber
1. Slide the appropriate boot onto the
fiber cable. Slide on the LC trigger after
installing the boot.
2. Furcation tube installation
Refer to page 2 for detailed instructions
3. Soft peel coating removal
Refer to page 2 for detailed instructions
5. Insert fiber into lead-in tube
Refer to page 2 for detailed instructions
6. Verification light
Refer to page 2 for detailed instructions
• Cleerline SSFTM can be terminated per standard connector using soft peel coating for buffer measurement if desired. Our exclusive SSFTM coating allows cleave lengths to be
adjusted to simplify the process of termination.
• Dependent upon specific connector model/type activator mechanism may need to be placed in the “open” position.
• SSFTM Fiber does not require the use of alcohol cleaning as the glass is not exposed and is protected with SSFTM proprietary coating. Remove soft peel with fingers only. Alcohol can
be used if desired.
• Due to the bend insensitivity of SSFTM fiber, your cleaver may require a wheel height adjustment to be properly cleaved.
This guide assumes proper selection of connector matching cable type.
20
10 10
(A) SSFTM Fiber = 125µm
(B) Soft Peel* = 250µm
(C) 2.0mm & 3.0mm Jacket
*(A) 10mm from 900/250µm
*12mm Soft Peel is an approx.
This instructional supplements the installation guide for Corning UniCam® connectors. SSFTM fibers have a integral polymer that
provides incredible bend and durability properties with a 250 micron soft peel acrylate. SSFTM fibers can be handled much like
typical buffered 900um fibers in both strength and durablity. Following the installation steps in the Corning manual and adding or
deleting the specific steps as noted for installation with 250um, 900 micron buffered and furcated, or 2.0mm & 3.0mm jacketed
cables will provide for ease of installation. This instructional illustrates 2.0mm & 3.0mm installation.
For connector installation, unless your connectors include a 900 micron furcation build up tube, please obtain this part from
Cleerline as it is necessary for optimum termination as noted in this instructional.
(A) (B) (C)
To Scale
CLEERLINE
TECHNOLOGY GROUP
TM
cleerlinefiber.com
Revise #3
Cleerline SSF TM Corning Unicam®LC Termination With:
SSF TM Jacketed Fiber 2.0mm/3.0mm
Do Not
Use Strippers
Corning UniCam® – 2.0 & 3.0mm Jacketed Cable - *Follow standard Corning preparation steps unless
otherwise noted. Items below refer to the Corning UniCam® installation manual noted by section:
Section 4
1) Measure and mark standard Corning measurements on the jacket at two points being 40mm
(mark #1) from the cable end and 53 mm (mark #2) from the cable end. Remove 40mm of jacket
with stripping tool.
2) Use the correct opening in the stripping tool for jacket size.
3) Use scissors to trim the aramid yarn flush with the end of the outer jacket. (At your mark #1)
4) Remove 13mm of jacket at mark #2 exposing 13mm of aramid yarn using stripping tool.
5) Fold the yarn back over the cable jacket and slide the crimp ring about 5mm down the cable to
hold it out of the way.
6) In place of steps #6 thru # 8 in the installation manual perform the following SSFTM specific steps
(refer to page 1 for “Figure A through E” callouts):
Figure A. Slide a piece of 40mm long furcation tubing onto the SSFTM fiber to build up to 900
micron. If not supplied with your particular connector this tubing can be obtained at www.
clrtec.com. Slide the piece of tubing onto the SSFTM 250um fiber. Push the tubing into the
jacketed cable leaving 6mm exposed.
Figure B. Gently remove the “Soft Peel” coating with finger tips to within 10mm of jacket.
Upon completion extend the furcation tubing out of the cable jacket to this same 10mm.
Do not attempt to remove 250um soft peel coating with ber strippers.
Section 5 - SSFTM Specific Instruction - refer to Figure C on page 1:
Figure C. The Corning FBC-015 typically cannot cleave SSFTM fiber due to the fiber’s polymer
coating which increases bend and extreme durability. Cleave the fiber with a precision wheel
cleaver for the best cleave possible.
Section 6 - SSFTM Specific Instruction - refer to Figure D & E on page 1:
Figures D & E. Follow standard connector termination steps using the TPA-2801 [or TPA-
2802] for inserting the cleaved fiber, maintaining a bow in the fiber, activating the cam button,
obtaining a green verification light, followed by rotating the crimp knob to secure the crimp
sleeve.
Completing the Connector Assembly – Jacketed Cable - follow standard Corning installation steps –
Section 6.2 of the installation manual:
1 Ensure the ferrule dust cap is installed
2) Hold the cable and slide the crimp ring back away from the connector along the cable jacket to
free the aramid yarn.
3) Flare the yarn around the connector. The ends of the yarn should just touch the back of the
square cam. If the yarn is too long, trim to length.
4) Hold the connector and push the crimp ring over the aramid yarn and against the back of the
connector’s cam.
5) Place the connector crimp ring into the opening of the crimp tool jaws.
6) Squeeze the handles until they automatically release indication completion of crimp.
7) Proceed to the description of your connector type for complete connector assembly.
Section 6.2.2 - Slide the trigger up to the back of the connector and latch its arms into the windows of
the housing. While holding the connector by the front dust cap, slide the correct strain-relief boot up
the back of the connector and under the trigger until it stops.
Cleerline SSF TM Corning Unicam®LC Termination With:
SSF TM Jacketed Fiber 2.0mm/3.0mm

Other Cleerline Cables And Connectors manuals

Cleerline SSF-48UHD-AOC-05m User manual

Cleerline

Cleerline SSF-48UHD-AOC-05m User manual

Cleerline SSF-48UHD-AOC-05m User manual

Cleerline

Cleerline SSF-48UHD-AOC-05m User manual

Popular Cables And Connectors manuals by other brands

ADTRAN BVL3AWWD Series quick start guide

ADTRAN

ADTRAN BVL3AWWD Series quick start guide

Gomax SP-5002PZQ user manual

Gomax

Gomax SP-5002PZQ user manual

ELEKTRA SelfTec16 ready2heat instruction manual

ELEKTRA

ELEKTRA SelfTec16 ready2heat instruction manual

MOB YAPO+ user manual

MOB

MOB YAPO+ user manual

Knaack Power Pass installation instructions

Knaack

Knaack Power Pass installation instructions

Tyco Electronics Raychem C25-21 manual

Tyco Electronics

Tyco Electronics Raychem C25-21 manual

TE Connectivity AMP-LATCH Application Specification

TE Connectivity

TE Connectivity AMP-LATCH Application Specification

Converters.TV 470 Operation manual

Converters.TV

Converters.TV 470 Operation manual

Ikelite 4102.15 instruction manual

Ikelite

Ikelite 4102.15 instruction manual

Lindy 38490-4 user manual

Lindy

Lindy 38490-4 user manual

HP 175X - JetDirect Print Server user guide

HP

HP 175X - JetDirect Print Server user guide

BrassCraft ProCoat CSSL SELECTION & INSTALLATION INSTRUCTIONS

BrassCraft

BrassCraft ProCoat CSSL SELECTION & INSTALLATION INSTRUCTIONS

CYP CDPS-UA1H10HS Operation manual

CYP

CYP CDPS-UA1H10HS Operation manual

TE Connectivity 025/250 instruction sheet

TE Connectivity

TE Connectivity 025/250 instruction sheet

Sennheiser AC 3000 Product sheet

Sennheiser

Sennheiser AC 3000 Product sheet

Kramer WP-209 user manual

Kramer

Kramer WP-209 user manual

Keysight 16048A Operation and service manual

Keysight

Keysight 16048A Operation and service manual

Philips SWA2084 Specifications

Philips

Philips SWA2084 Specifications

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.