10 Hearth & Home Technologies • SMART-BATT-II Remote Control Instructions • 100-909 Rev. i • 5/12
Child Proof Lockout (CP)
The transmitter contains a “Child Proof” lockout feature that
preventsunauthorizeduse oftheremotecontrol. Toaccess
the “Child Proof” activation button, remove cover on BACK
of transmitter. To activate LOCKOUT:
1. Pressand holdin the“settingbutton” for5 seconds.The
letters CP will display on the LCD screen (see Figure
13).This preventsthe activation offireplace. Whenany
function button is pressed ON/OFF etc. the letter CP
will display on the LCD screen.
To deactivate LOCKOUT:
1. Pressand holdin the“settingbutton” for5 seconds.The
LCD will display CP until 5 seconds have elapsed, and
then the LCD screen will return to its normal state.
TRANSMITTER SAFETY FEATURES
It is recommended that the TRANSMITTERS always be
located within a 20 foot operating range of the fireplace,
preferably in the same room in which the fireplace system
is located. The TRANSMITTER features several safety
features that alert the user when the TRANSMITTER is
placed outside the 20 foot normal operating range.
Thermo-Safety and Communication-Safety Features
This remote control has both a THERMO-SAFETY and
COMMUNICATION-SAFETYfunctionbuilt intoitssoftware.
Itprovides anextra marginof safety whentheTRANSMIT-
TER is out of the normal 20 foot operating range of the
receiver. It is also activated when the batteries become
weak or are removed from the transmitter.
In the THERMO-SAFETY feature (only in the THERMO or
TIMER modes) the transmitter normally reads the ROOM
temperature every 2 minutes. In addition to checking the
temperature,thetransmittersends a signaltothereceiverin-
dicating that the transmitter and its batteries are still active.
In the COMMUNICATION-SAFETY feature, at all times
and in all OPERATING MODES the transmitter sends a
signal every fifteen (15) minutes to the receiver, indicating
that the transmitter is within the normal operating range
of 20 feet.
Should the receiver NOT receive a transmitter signal every 2
minutes (THERMO-SAFETY feature) or 15 minutes (COM-
MUNICATION-SAFETYfeature),theRECEIVERwillbegina
2HOUR(120minute)countdowntimingfunction.Ifduringthis
2 hourperiod, thereceiver doesnot receivea signalfrom the
transmitter,theRECEIVERwillshutdownthefireplacebeing
controlled by the receiver. The RECEIVER will then emit a
series of rapid “beeps”. Then, after 10 rapid “beeps”, the RE-
CEIVERwillcontinuetoemitasingle“beep”every4seconds
until a transmitter signal is again received. The intermittent 4
second beeping will go on indefinitely until reset.
To “reset” the RECEIVER and operate the fireplace system:
1. Press the MODE button on the transmitter. The word
ON must display on the LCD screen. The THERMO-
SAFETYand COMMUNICATION -SAFETY operationis
overriddenandthesystemwill returntonormaloperation
depending on the MODE selected at the transmitter.
We recommend the user check the batteries in the
TRANSMITTER to make sure the voltage is no less than
2.7 volts.
Auto Shutdown
This remote control has an Auto Shutdown feature incor-
porated into its system. When the transmitter MODE is
in the ON position the fireplace will continuously operate
for 9 hours. After 9 hours, the fireplace will shut down. To
relight the fireplace:
1. Press the MODE button.
Thetransmitter mustbe positioned withina 20foot operat-
ing range for the Auto Shutdown feature to operate.
SYSTEM CHECK
Millivolt Valves
Light the appliance following the lighting instructions that
came with the fireplace. Confirm that the pilot flame is on.
It must be in operation for the main gas valve to operate.
1. Slidethe 3-positionbutton onthe remotereceiver tothe
ON position. The main gas flame (i.e., the fire) should
ignite.
2. Slide the button to OFF. The flame should extinguish
(the pilot flame will remain on).
3. Slide the button to REMOTE (the center position), then
press the MODE button on the transmitter to change
the system to ON. The main gas flame should ignite.
4. Press the MODE button on the transmitter to change
the system to OFF. The flame should extinguish (the
pilot flame will remain on).
5. Press the MODE button on the transmitter to change
the system to THERMO.
6. Advance the SET temperature on the transmitter to a
temperature of at least 2 ºF (1 ºC) above the ROOM
temperature displayed on the LCD screen and the
system flame will ignite.
7. Set the SET temperature to at least 2 ºF (1 ºC) below
the room temperature and the system flame will extin-
guish. Thereafter, it should continue to cycle on and
off thermostatically approximately every two minutes
as the ROOM temperature changes, but only when
the temperature differential between ROOM and SET
temperatures differs at least 2 ºF (1 ºC). The 2 ºF dif-
ferential is the factory setting.
Electronic Ignition System
1. Slidethe 3-positionbutton onthe remotereceiver tothe
ON position. The spark electrode should begin spark-
ing to ignite the pilot (the pilot may ignite after only one
spark). After the pilot flame is lit, the main gas valve
should open and the main gas flame should ignite.
2. Slide the button to OFF. The main gas flame and pilot
flame should BOTH extinguish.
3. Slide the button to REMOTE (the center position).