hebvest UC01SD User manual

UC01SD UC01GD
hebvest.com t 800.469.8908 | f 407.264.6309 | mike@hebvest.com
operator’s manual
Commercial Single Door Undercounter Coolers
performance • reliability • simplicity
Model No. Description
UC01SD Commercial Single Stainless Steel Door Undercounter Cooler
UC01GD Commercial Single Glass Door Undercounter Cooler

hebvest.com t 800.469.8908 | f 407.264.6309 | mike@hebvest.com
Commercial Single Door Undercounter Coolers
operating instructions:
1. The appliance is intended for commercial use or similar use (etc. to be used by a layman in shops).
2. DO NOT use the appliance outside.
3. DO NOT attempt to service the item yourself.
4. DO NOT use damaged appliances. If you are in any doubt, consult service agent.
5. DO NOT use electrical appliances inside the appliance (e.g. heaters, ice-cream makers etc.), unless
they are of the type recommended by the manufacturer.
6. Keep ventilation openings, in the appliance enclosure or in the built-in structure, clear of obstruction.
7. DO NOT use mechanical devices or other means to accelerate the defrosting process, other than
those recommended by the manufacturer.
8. DO NOT damage the refrigerant circuit.
9. DO NOT stand or support yourself on the base, drawers or the door.
10. DO NOT allow oil or fat to come into contact with the plastic components or door seal.Clean
immediately if contact occurs.
11. DO NOT place combustible, explosive or volatile articles, corrosive acids or alkalis or liquids in the
appliance.
12. DO NOT use this appliance to store medical supplies.
13. DO NOT use jet/pressure washers to clean the appliance.
14. DO NOT allow children to play with the packaging, and destroy plastic bags safely.
15. Bottles that contain a high percentage of alcohol must be sealed and placed vertically in the
refrigerator.
16. Always carry, store and handle the appliance in a vertical orientation and move by holding the base
of the appliance.
17. Always switch off and disconnect the power supply to the unit before cleaning.
18. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.
19. This appliance is not intended for use by persons (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their safety (IEC603365-1).
20. Children should be supervised to ensure that they do not play with the appliance. (IEC 60335-1)
21. This appliance can be used by children aged from 8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of experience and knowledge if they have been given
supervision or instruction concerning use of the appliance in a safe way and understand the hazards
involved. Children shall not play with the appliance, Cleaning and user maintenance shall not be
made by children without supervision.(EN 60335-1)
22. Keep the appliance and its cord out of reach of children less than 8 years.
23. Any repairs and work on the appliance should only be carried out by the customer service
department.
24. Maximum loading of each shelf is 66 lbs.
25. The key to the fridge/freezer should be kept out of the reach of children and users.
26. If the cabinet is no longer in use and you wish to proceed with disposal please read chapter
‘disposal’ of this instruction manual. Please note that the blowing gases in products are flammable.
27. Appliance is built to be working according to ISO climatic classification class 4, meaning wherever
the temperature not exceeds 80°F and relative humidity not exceed 55%.
28. Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance.
29. When disconnected from the power, The removal of the plug has to be such that an operator can
check from any of the points to which he has access that the plug remains removed.

hebvest.com t 800.469.8908 | f 407.264.6309 | mike@hebvest.com
Commercial Single Door Undercounter Coolers
intended use
controler operations instructions
operation
Only use this appliance for cooling and storage of food and beverage for commercial purposes.
Turn on:
1. Close the door of the appliance.
2. Ensure the power switch is set to [O] and insert plug into socket.
3. Switch on the Power{I}. The current temperature within the appliance is displayed.
4. The on the display will flash for 3-min to indicate a delay between the motor
compressor being stopped and then restarted.
Temperature setting and control
Thermoatat display and contro panel
How to see the set point:
Push and immediately release the SET key, the set point will be showed;
Push and immediately release te SET key again or wait about 5s to return to normal visualization.
How to change the set point:
Push the SET key for more than 2 seconds to chagne the set point value;
The value of the set point will be displayed and the “oC” start blinking ;
To change the set value push the “ ”(up) or “ ” (down)arrows within 10s.
To memorze the new set point values push the SET key again or wait 10s.
Further instructions:
Refer to manufactures instruction manual or a qualified service agent for
modifications to the controller to your requirements.
Plug in the cabinet.
The display shows the actual cabinet temperature
Servicing
Make sure the appliance is switched off at the mains before service is performed on electrical parts

hebvest.com t 800.469.8908 | f 407.264.6309 | mike@hebvest.com
Commercial Single Door Undercounter Coolers
controler operations instructions
The front panel of the thermostat
1. Compressor operation light
2. Defrosting light
3. Energy saving light
4. Stand-by light
5. Programming key (service agent only)
6. Machine On/Stand-by (keep pushed)
7. Manual defrost (keep pushed)
How to unlock the keyboard (»Loc» message)
• Push any button for more than 2s, «UnL» message will appear and the keyboard will be unlocked.
Note: for safety reasons the keyboard locks automatically after 30s of keys inactivity.
To execute any operation, please unlock the keyboard first.
How to see and modify the set point
• Push and immediately release the key, the set point will be showed and starts blinking;
• To change the set value push or arrows within 20s.
• To memorize the new set point value push the key again or wait 20s.
Manual Defrost
The appliance will automatically run a defrost cycle every 12 hours.
Note: the cycle starts from the time the appliance is initially powered up.
To manually defrost the applicance:
• Press and hold the DEFROST button for 3s;
• The defrost cycle will start immediately and the LED illuminates. The defrost will last 20 minutes.
Note: starting a manual defrost also resets the automatic defrost timer. The next automatic
defrost will start 12 hours after the manual defrost has finished.
How to turn the machine in ON / STAND-BY status
• Press and hold the key for 4s, the machine will turn from ON to STAND-BY status and vice-versa.
During the button hold the LED will blink to show status changing

hebvest.com t 800.469.8908 | f 407.264.6309 | mike@hebvest.com
Commercial Single Door Undercounter Coolers
defrosting procedure
changing the door hinge
Refrigerator: Automatic Defrosting using automatic water evaporation.
Automatic defrost:
The appliances will automatically run a defrost cycle every 6 hours.
Note: The cycle starts from the time the appliance is initially powered up.
To manually defrost the appliance:
• Press and hold the DEFROST button for 5 seconds.
• The defrost cycle will start immediately and the Defrost LED illuminates. The defrost will last 20 minutes.
Note: Starting a manual defrost also resets the automatic defrost timer. The next
automatic defrost will start 6 hours after the manual defrost has finished.
Freezer: Manual defrosting by switching off and disconnecting the wait until all the ice inside has been melted.
The condensation water must be collected.
Never use a sharp or pointed object that may damage the freezer/refrigerator.
The door can be changed from right hand-hinged to left hand-hinged, or vice versa.
To do so, proceed as follows:
1. Switch off power and disconnect from the main socket
Remark: It has a small roller that helps slide the door when closing and function as a door support.
Hinge 3 (Upper door hinge)
Hinge 4 (Lower door hinge)
Hinge 1* Hinge 2
(see remark)

hebvest.com t 800.469.8908 | f 407.264.6309 | mike@hebvest.com
Commercial Single Door Undercounter Coolers
changing the door hinge
2. Remove the hinge 2
3. Take off the door

hebvest.com t 800.469.8908 | f 407.264.6309 | mike@hebvest.com
Commercial Single Door Undercounter Coolers
changing the door hinge
4. Remove the hinge 1
5. Change two hinges positions
6. Fix the hinge1

hebvest.com t 800.469.8908 | f 407.264.6309 | mike@hebvest.com
Commercial Single Door Undercounter Coolers
changing the door hinge
7. Remove Hinge 4 (Lower door hinge)
8. Remove Hinge 3 (Upper door hinge)

hebvest.com t 800.469.8908 | f 407.264.6309 | mike@hebvest.com
Commercial Single Door Undercounter Coolers
changing the door hinge
9. Exchange Hinge 3 and Hinge 4‘s position.
10. Fix Hinge 3 and Hinge 4 on the door

hebvest.com t 800.469.8908 | f 407.264.6309 | mike@hebvest.com
Commercial Single Door Undercounter Coolers
changing the door hinge
11. Turn the door up side down and connect to the upper hinge.
12. Fix Hinge2

hebvest.com t 800.469.8908 | f 407.264.6309 | mike@hebvest.com
Commercial Single Door Undercounter Coolers
general maintenance
Before cleaning, switch off the cabinet and disconnect from the mains.
This is best done with a vacuum cleaner and a brush.
The cabinet should be kept clean using a mild soap solution. Do not use abrasive cleansers. The
plastic parts cannot withstand boiling water(max. temperature 185°F).
When regular cleaning is performed, be sure to wipe clean the rubber door gasket to ensure any
sticky substances are removed that would otherwise damage the gasket.
The condenser fan air outlet above the compressor must be free of leaves, paper etc. to ensure
normal operation of the cabinet.
This is best done with a vacuum cleaner and a brush.
Routine Maintenance:
Switch off and disconnect from the power supply before cleaning.
• Clean the enclosure and interior of the appliance as often as possible.
• Clean the unit with a moist cloth. Never allow the switch, control panel, cable or plug to get wet.
• Do not use abrasive cleaning agents. These can leave harmful residues. Use only mild soapy water.
• Clean the door seal with water only.
• Ensure that no cleaning water penetrates into the electrical components.
• Must not be cleaned by a water jet.
• Always wipe dry after cleaning with a soft cloth.
• Take care when cleaning the rear of the appliance.
• An agent or qualified technician must carry out repairs if required.
If the appliance is to be left inactive for long periods, unplug the appliance after having turned the
switch to OFF
position, empty the refrigerating compartment and clean thoroughly. Please leave the door open to
avoid the development of odor and mildew.
Special Maintenance: Periodic Operations: Qualified Persons Only
• Periodically clean the condenser using suitable tools. (vacuum cleaner or soft brushes).
• Check that the electrical connections are not loose.
• Check that the thermostat and the sensor are in proper working order.
• Periodically cleaning the condenser can extend the life of the appliance.
• Recommend that an agent or qualified technician clean the condenser.
• The key to the electrical cabinet should be kept out of the reach of children and users.
• Only use the key to open the lock.

hebvest.com t 800.469.8908 | f 407.264.6309 | mike@hebvest.com
Commercial Single Door Undercounter Coolers
wiring diagram
STANDARD

hebvest.com t 800.469.8908 | f 407.264.6309 | mike@hebvest.com
Commercial Single Door Undercounter Coolers
trouble shooting
If your Refrigerator, Freezer appliance develop a fault, please check the following table.
Fault Probable Cause Action
The appliance is not working The unit is not switched on Check that the unit is plugged in
correctly and switched on
Plug and/or lead are damaged Call our agent or qualified technician
Power supply Check power supply
Internal wiring fault Call our agent or qualified
technician
The appliance turns on, but the Too much ice on the evaporator Defrost the appliance
temperature is too high/low
Condenser blocked with dust Clean the condenser thoroughly by
qualified technician
The door is not shut properly Check that the door is shut and
seals are not damaged
Appliance is located near a heat Move the refrigerator to a more
source, or air flow to the suitable location
condenser is blocked
Ambient temperature is too high Increase ventilation or move
appliance to a cooler position
Unsuitable foodstuffs are being Remove any excessive hot
stored in the appliance foodstuffs or blockages to the fan
Appliance is overloaded Reduce the amount of food stored
in the appliance
The appliance is leaking water The appliance is not properly Adjust the screw feet to level the
(Refrigerator) levelled appliance
The discharge outlet is blocked Clear the discharge outlet
The water container is damaged Call our agent or qualifi ed technician
The appliance is unusually loud Loose nut/ screw Check and tighten all nuts and screws
The appliance has not been Check installation position and
installed in a level or stable position change if necessary