Installation Instructions
1. Before installation and/or use of this appliance please read these instructions carefully to ensure that all requirements are fully understood. The
appliance must be fitted by a registered installer*, or approved by your local building control officer.
2. All local regulations, including those referring to national and european standards need to be complied with when installing the appliance. In all
cases the installation must comply with current local regulations including Building Regulations, Local Authority Byelaws and other specifications or
regulations including Ireland, UK or EU standards referred to as they affect the installation of the stove. Please refer to
Building regulations available on http://www.environ.ie and http://www.planningportal.gov.uk.
3. Only use for domestic heating in accordance with these operating instructions.
4. Only approved fuels must be burned. Do not use with liquid fuels or as an incinerator.
5. Appliance surfaces become very hot when in use. Use a suitable fireguard if young children, elderly or infirm persons are present.
6. Do not place photographs, TV’s, paintings, porcelain or other combustible items on the wall or near the appliance. Exposure to hot temperatures
will cause damage. Do not place furniture, or other items such as drying clothing, closer than 1m from the front of this appliance.
7. Extractor fans or cooker hoods must not be placed in the same room or space as this can cause the appliance to emit fumes into the room.
8. Do not obstruct inside or outside ventilation required for the safe use of this appliance.
9. Do not make unauthorised changes to the appliance.
10. The chimney must be swept at least once a year
11. Do not connect, or share, the same flue or chimney system with another appliance.
12. The serial number is required when ordering spare parts or making warranty claims. It is found on the appliance data plate.
www.henleystoves.com | 5
Hearth
The appliance must stand on a non-combustible constructional hearth which is
at least 125mm thick. The building must have a suitable load-bearing capacity
for the hearth and appliance. Consult a structural engineer for advice before
proceeding. When fitting into an existing hearth check that the hearth complies
with current construction regulations and is at least the minimum sizes shown.
If there is no existing fireplace or chimney it is possible to construct a suitable
non-combustible housing and hearth setting. The flue must be installed in
accordance with all local and national regulations and current rules in force.
Check if adding a new chimney to your property requires planning permission.
The hearth must protrude at least 250mm in front of the stove and 150mm
each side. If the hearth is constructed on timber, there must be a clearance of
at least 250mm from the timber to the top surface of the hearth.
Ventilation
This appliance requires a constant supply of air to maintain proper combustion and effective flue performance. An inadequate air supply can result
in poor combustion and smoke entering the room which is potentially dangerous. This supply of air can come from either:
• The natural leakage of air into the room in which the product is tted.
• Purpose provided ventilation.
The amount of air required must comply with local building regulations and the rules in force. If spillage is detected during commissioning then
there may be insufficient natural ventilation and an additional air supply will be necessary. Many older buildings are sufficiently ventilated by natural
leakage of air to provide suitable air supply for an appliance of 5kW output or less.
Extractor fans should not be installed in the same room as the appliance and any air vents should be positioned so that they are not liable to block-
age.
Chimney
The chimney draw is critical on any installation and should be checked to ensure that it matches what is specified. If it is higher than
recommended provision must be made to correct the overdraw. The draw can vary in different weather conditions and the customer should be
made aware of this. Failure to correct an over-drawing flue will invalidate the warranty, and may damage the appliance.
Please remember that chimney draught is dependent on four main factors.
• Flue gas temperature • Flue height • Flue size • Flue terminal
The flue or chimney system must be in good condition. It must be inspected by a competent person and passed for use with the appliance before
installation. Products of combustion entering the room can cause serious health risks.
The following must be checked:
• The construction of the masonry chimneys, ue block chimneys and connecting ue pipe system must meet the requirements of the Building
Regulations.
• A exible ue liner system can be used if certied for use with solid fuel systems and installation complies with manufacturer’s instructions and
Building Regulations. The flue liner must be replaced when an appliance is replaced, unless proven to be recently installed and in good condition.