Hilintec C15 User manual

Copyright © Chengdu Hilin Technology Co., Ltd.
D15 Flow Control Vacuum Pump and Compressor
Series
User Guide
Issue
08
Date
2020-06

D15 Flow Control Vacuum Pump and Compressor Series User Guide
Copyright © Chengdu Hilin Technology Co., Ltd.
Copyright © Chengdu Hilin Technology Co., Ltd. 2020. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means
without prior written consent of Chengdu Hilin Technology Co., Ltd.
Trademarks and Permissions
is a trademark of Chengdu Hilin Technology Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of
their respective holders.
Notice
The purchased products, services and features are stipulated by the contract made
between Chengdu Hilin Technology Co., Ltd. and the customer. All or part of the products,
services and features described in this document may not be within the purchase scope or
the usage scope. Unless otherwise specified in the contract, all statements, information,
and recommendations in this document are provided "AS IS" without warranties,
guarantees or representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has
been made in the preparation of this document to ensure accuracy of the contents, but all
statements, information, and recommendations in this document do not constitute a
warranty of any kind, express or implied.
Chengdu Hilin Technology Co., Ltd.
Address:
No.3663 Section 2 Muhua Road
Shuangliu District
Chengdu Sichuan China 610000
Website:
http://www.hilintec.com
Tel:
+86-28-62567958

D15 Flow Control Vacuum Pump and Compressor Series User Guide
Copyright © Chengdu Hilin Technology Co., Ltd.
I
About This Document
Purpose
This document is a description of the D15S flow control vacuum
pump and compressor series in the test period, which is used to
guide the relevant technical personnel to understand the product
characteristics.
Intended Audience
This document is intended for technical personnel. You should have
a good understanding of your product and have a clear concept of
the relevant parameters, specifications, and other information of the
applications of the micro pump.
Keyword
PWM Speed Control, working status indicator, related parameters,
wiring instructions

D15 Flow Control Vacuum Pump and Compressor Series User Guide
Copyright © Chengdu Hilin Technology Co., Ltd.
II
Change History
The change history accumulates each update of this document. The
latest version of the document contains all the previous updates.
Issue
Date
Product
Version
Issuer
Modification
01
2018-3
1.0
LT
First official release
02
2018-10
1.0
LT
Add product images
and models of
matching speed
controllers
03
2018-11
1.0
LT
Add product version
description and speed
feedback description
04
2019-09
1.0
LYZ
Modify the document
format
05
2019-12
1.0
FB
Update notes in section
3.1
06
2020-02
1.0
FB
Add model
description; update
outline drawing
07
2020-03
1.0
FB
Update definition of
FG feedback signal
08
2020-06
1.0
FB
Update medium
description

D15 Flow Control Vacuum Pump and Compressor Series User Guide
Copyright © Chengdu Hilin Technology Co., Ltd.
III
Contents
About This Document............................................................................................... I
Change History..........................................................................................................II
Contents.................................................................................................................... III
1Product Characteristics........................................................................................1
1.1 Compact Size....................................................................................................................................... 1
1.2 Working Status Indicator......................................................................................................................1
1.3 Brushless Motor................................................................................................................................... 1
1.4 Protections............................................................................................................................................1
2Special Features.....................................................................................................2
2.1 Speed Control Feature..........................................................................................................................2
2.2 Warning Feature................................................................................................................................... 2
3Technical Parameters........................................................................................... 3
3.1 Key Parameters.................................................................................................................................... 3
3.2 Description of Versions........................................................................................................................ 3
3.3 Life-time Test Conditions.................................................................................................................... 4
3.4 Working Conditions............................................................................................................................. 4
3.5 Materials...............................................................................................................................................5
3.6 Parameter Curve...................................................................................................................................5
4Product Model Description................................................................................. 6
4.1 Brief Description of Model Naming.................................................................................................... 6
This series of pumps are mainly: basic type.............................................................................................. 6
5Electrical Connection............................................................................................7
6Cautions................................................................................................................. 10
7Dimensions............................................................................................................ 11
8Appearance............................................................................................................12

D15 Flow Control Vacuum Pump and Compressor Series User Guide
Copyright © Chengdu Hilin Technology Co., Ltd.
1
1Product Characteristics
1.1 Compact Size
The product weighs about 50g and the overall size is about
50x29x36mm.
1.2 Working Status Indicator
The bottom case of the pump is made of light-transmitting material
ABS, which can visually reflect the working status of the pump
through the indicator light.
1.3 Brushless Motor
This model is driven by brush-less motors which have the
advantages of long service life, low interference and high reliability.
1.4 Protections
Equipped with overheating protection, overload protection and
reverse connection protection function to prevent accidental damage
to the pump.

D15 Flow Control Vacuum Pump and Compressor Series User Guide
Copyright © Chengdu Hilin Technology Co., Ltd.
2
2Special Features
2.1 Speed Control Feature
The flow can be changed by adjusting the motor speed of the pump
(by adjusting the PWM duty cycle).
Or by ordering our company's special speed controller for micro
pump (model: TS-G12) to regulate the speed.
2.2 Warning Feature
The color of the indicator light displayed on the transparent bottom
case (as shown in Figure 2-1 and Figure 2-2) can feedback the
working status of the pump:
1. It is normal when the blue light flashes regularly;
2. When the light remains red, it is abnormal, i.e. the motor runs too
low;
3. When the red and blue lights alternately flash, it is abnormal , and
at this time,the motor speed is low and unstable;
4. The indicator light is off when the positive and negative
connections are reversed;
5. When the voltage is out of the working voltage range (3.2V~6V),
the indicator light is off.
Figure 2-1 Normal working status Figure 2-2 Abnormal working status

D15 Flow Control Vacuum Pump and Compressor Series User Guide
Copyright © Chengdu Hilin Technology Co., Ltd.
3
3Technical Parameters
3.1 Key Parameters
Model
Voltage
(V DC)
Load
Current
(A)
Flow(L/min)
Relative
Vacuum
(-kPa)
Maximum
Output
Pressure
(kPa)
Weight
(g)
Peak Flow
Average
Flow
D15S
5
≤280
≥0.4
≥0.4
≥18
≥22
≈50
Note:
1.Working voltage is 3.2V~6V, input voltage change will affect the load current;
2.Unless otherwise specified, the technical parameters are measured under the
conditions of temperature 25℃ and standard atmospheric pressure of 101kPa. For
products with other parameters and specifications, you can contact us to customize.
3.The parameters in the table are measured at the maximum speed of the motor
under rated voltage. When the motor speed changes, the pressure/vacuum level is
basically unchanged.
4.The peak flow rate in the table refers to the flow value measured with a rotameter,
and the average flow rate is measured with a soap film flow-meter.
3.2 Description of Versions
Performance
Version
Simplified
Version
Standard Version
Premium Version
Life time
>2500h
>6000h
>10000h
Noise
★
★★
★★★

D15 Flow Control Vacuum Pump and Compressor Series User Guide
Copyright © Chengdu Hilin Technology Co., Ltd.
4
Reliability
★
★★
★★★
Parameter
Consistency
★
★★
★★★
Speed Feedback
None
Equipped with FG signal feedback
Speed Controller
None
Compatible with TS-G12 type speed controller
Note: 1. The more ★, the better performance of this item.
2. The noise data of the simplified version and the standard version are not
specified. For the noise data of the premium version, please refer to the
latest information.
3.3 Life-time Test Conditions
In a clean, non-corrosive laboratory, the pump carries a full load(the
inlet is blocked and the outlet directly connected to the atmosphere),
and operates continuously around the clock. The ambient temperature
is 5℃ ~33℃, fluctuates with the climate; the relative humidity is
30%~90%, which fluctuates with the climate.
3.4 Working Conditions
1. Environment: Permissible ambient temperature range of the pump
is 0 ℃ ~ 50 ℃, permissible relative humidity is ≤90%, no
condensation. The pump should not be exposed to the sun, and
should work in a clean and ventilated environment.
2.Medium: Permissible gaseous media temperature range is 0 ℃ ~
50℃. The medium is allowed to be rich in water vapor, but cannot
contain particles or oil mist.
3. Load:
1) When used as a compressor: the outlet can run at full load ( i.e.
the inlet is completely blocked), but the applied load cannot exceed
the maximum discharge pressure of the pump; the inlet must keep
unobstructed.
2) When used as a vacuum pump: the inlet can operate at full load
( i.e. the inlet is completely blocked), but the applied load cannot

D15 Flow Control Vacuum Pump and Compressor Series User Guide
Copyright © Chengdu Hilin Technology Co., Ltd.
5
exceed the maximum vacuum of the pump; the outlet must be
unobstructed.
3.5 Materials
1. The materials of the wetted parts: reinforced nylon and EPDM
rubber, which have certain corrosion resistance. Please check the
chemical resistance and compatibility of the medium according to
the wetted material.
2. The pump body is made of reinforced nylon for plastic parts,
EPDM for elastomer parts and light-transmitting ABS for bottom
case.
3.6 Parameter Curve
Vacuum degree-flow curve, there are individual differences between
different micro pumps, this curve is a statistical value, only as a
technical reference for users to confirm the working point. The
"flow" mentioned in this section refers to the "average flow".
(to be updated……)
Note: 1. The maximum average flow rate of the curve will be slightly lower than the
nominal value, which is due to the resistance of the test pipeline components,
which leads to the attenuation of the flow;
2. The value of this curve is for reference only, not as a basis for product
acceptance.

D15 Flow Control Vacuum Pump and Compressor Series User Guide
Copyright © Chengdu Hilin Technology Co., Ltd.
6
4Product Model Description
4.1 Brief Description of Model Naming
Only basic type type available for this series of pumps.
Note: If the remarks starts with a letter, it means a special custom function. For
example, letter"GJ" means customized high-temperature medium function,
and "GH", means customized high-temperature environment function. If it
starts with a number, it means other information.
Example 1: D15S-51J (D15S pump, simplified version of 5V voltage basic type

D15 Flow Control Vacuum Pump and Compressor Series User Guide
Copyright © Chengdu Hilin Technology Co., Ltd.
7
5Electrical Connection
The electrical connection is for connecting the external power supply and
signal wires of this product. The definition of the wires is distinguished
by color.
5.1 Definition of Signals
This is a product with basic functions. There are 3 wires. The wiring and usage
instructions are as follows.
S.N
Wire
Signal
Function
Definition of Signal
Remarks
1
Red
Vm
Positive pole
of the power
supply
+3.2V~+6V
The voltage is not
allowed to exceed
6V, otherwise it
will burn the motor.
2
Black
GND
Negative pole
of the power
supply,ground
3
White
PWM
Pulse Width
Modulation
(PWM)
Pulse width
modulation signal,
active at low level
0V≤low level≤
0.8V
Start
2V≤high level≤5V
Stop
carrier-frequency
range:
15kHz~25kHz
Select a fixed a
value of frequency
within the range of
15kHz ~25kHz,
and adjust the speed
by changing the
duty cycle
4
Yellow
FG
FG feedback
signal
The motor speed
feedback signal is a
3.3V pulse signal,
and the motor outputs
6 pulses per rotation.
Speed feedback
function
unavailable with
simplified version
and there is no such
wire.

D15 Flow Control Vacuum Pump and Compressor Series User Guide
Copyright © Chengdu Hilin Technology Co., Ltd.
8
Note: More wiring will be added with more functions to be added into the
product,and this table will also be updated.
5.2 Logical Wiring Diagram
When the speed control function is not needed, the white connection
wire PWM input signal and the black connection wire can be
grounded together, the yellow wire must be insulated and wrapped,
and the micro pump will work at the rated speed.
Note: The speed feedback function is unavailable with the simplified version so
there is no yellow FG signal line.
When you need to use the PWM speed control function, you need to
use a signal source that supports PWM signal output (function
signal generator, MCU, PLC, etc.), connect the signal source output
to the white PWM input cable, and connect the PWM signal source
ground to the DC power ground. If you do not need to monitor the
speed feedback signal, the FG signal line must be insulated and
wrapped. The speed feedback function is unavailable with the
simplified version so there is no yellow FG signal line.

D15 Flow Control Vacuum Pump and Compressor Series User Guide
Copyright © Chengdu Hilin Technology Co., Ltd.
9
When you need to use the PWM speed control function and obtain
the FG feedback, you need to use a signal source that supports
PWM signal output (function signal generator, MCU, PLC and
other controllers) and an oscilloscope or host computer, and connect
the signal source output to the white PWM input. Connect the PWM
signal source ground to the DC power ground, connect the yellow
FG feedback signal line to the oscilloscope probe or the host
computer input, and connect the oscilloscope or host computer
ground wire to the black ground wire. If the FG signal wire is not
used, it must be insulated and wrapped. The speed feedback
function is unavailable with the simplified version so there is no
yellow FG signal line.

D15 Flow Control Vacuum Pump and Compressor Series User Guide
Copyright © Chengdu Hilin Technology Co., Ltd.
10
6Cautions
Please read the instructions in this chapter carefully and follow
the instructions strictly before use.
1. This product has no waterproof, dust-proof, and explosion-proof
functions and cannot be used in flammable and explosive environments!
2. Foreign matter must not fall into the gas nozzles, and there should be
no solid particles in the medium, otherwise the micro pump will be
damaged!
3. The outlet must keep unobstructed, otherwise the micro pump will
be damaged!
4. When this product is used to transfer harmful medium, it must be
double-sealed to ensure personal safety!
5. The matching piping components and containers must have
sufficient strength to ensure personal safety!
6. Please follow the instructions strictly!

D15 Flow Control Vacuum Pump and Compressor Series User Guide
Copyright © Chengdu Hilin Technology Co., Ltd.
11
7Dimensions
Installation instructions:
1. The screws on the pump cannot be removed, otherwise it will damage the
pump;
2. The mounting hole is a self-tapping screw hole, which is not easy to be
repeatedly tightened and disassembled, otherwise it will cause loose and
unreliable installation.

D15 Flow Control Vacuum Pump and Compressor Series User Guide
Copyright © Chengdu Hilin Technology Co., Ltd.
12
8Appearance
Other manuals for C15
1
This manual suits for next models
2
Table of contents
Popular Control Unit manuals by other brands

BRUEL & KJAER
BRUEL & KJAER 3015 Service manual

Ingersoll-Rand
Ingersoll-Rand ARO STOP 23644-400 Operator's manual

Graco
Graco 24P976 instructions

Sierra Wireless
Sierra Wireless MC Series Hardware integration guide

Etherma
Etherma eNEXHO-PS Assembly and operating instructions

Promatic
Promatic Game Trailer Radio operating instructions