HMS Anybus AWB4004 User guide

Anybus®WLAN Access Point IP67
STARTUP GUIDE
SP2383 1.3 en-US ENGLISH

Important User Information
Disclaimer
The information in this document is for informational purposes only. Please inform HMS Industrial
Networks of any inaccuracies or omissions found in this document. HMS Industrial Networks disclaims
any responsibility or liability for any errors that may appear in this document.
HMS Industrial Networks reserves the right to modify its products in line with its policy of continuous
product development. The information in this document shall therefore not be construed as a
commitment on the part of HMS Industrial Networks and is subject to change without notice. HMS
Industrial Networks makes no commitment to update or keep current the information in this document.
The data, examples and illustrations found in this document are included for illustrative purposes and are
only intended to help improve understanding of the functionality and handling of the product. In view of
the wide range of possible applications of the product, and because of the many variables and
requirements associated with any particular implementation, HMS Industrial Networks cannot assume
responsibility or liability for actual use based on the data, examples or illustrations included in this
document nor for any damages incurred during installation of the product. Those responsible for the use
of the product must acquire sufficient knowledge in order to ensure that the product is used correctly in
their specific application and that the application meets all performance and safety requirements
including any applicable laws, regulations, codes and standards. Further, HMS Industrial Networks will
under no circumstances assume liability or responsibility for any problems that may arise as a result from
the use of undocumented features or functional side effects found outside the documented scope of the
product. The effects caused by any direct or indirect use of such aspects of the product are undefined
and may include e.g. compatibility issues and stability issues.
Anybus®WLAN Access Point IP67 Startup Guide SP2383 1.3 en-US

Anybus®WLAN Access Point IP67 Startup Guide SP2383 1.3 en-US
Table of Contents Page
1 About This Document . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . 3
1.1 Document Conventions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2 Safety ...................................................................... 4
2.1 General Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.2 Intended Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.3 5 GHz Transmission Power Restriction (EU only). . . . . . . . . . . . . . . . . . . . . . . . . . 5
3 Installation................................................................. 6
3.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.2 Wall Mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3.3 Pole Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.4 Power Connector (M12) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3.5 Ethernet Connector (M12) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3.6 Ethernet Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3.7 Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3.8 LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
4 Configuration .............................................................14
4.1 Factory Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
5 Technical Data ............................................................15
5.1 Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
5.2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

This page intentionally left blank

About This Document 3 (18)
1 About This Document
This document describes how to install Anybus WLAN Access Point IP67.
For additional documentation and software downloads, FAQs, troubleshooting
guides and technical support, please visit www.anybus.com/support.
1.1 Document Conventions
The following conventions are used to indicate safety information and other
important content in this document:
WARNING
Instruction that must be followed to avoid a risk of death or serious injury.
Caution
Instruction that must be followed to avoid a risk of personal injury.
Instruction that must be followed to avoid a risk of reduced functionality
and/or damage to the equipment, or to avoid a network security risk.
Additional information which may facilitate installation and/or operation.
Anybus®WLAN Access Point IP67 Startup Guide SP2383 1.3 en-US

Safety 4 (18)
2 Safety
2.1 General Safety Instructions
Caution
This equipment emits RF energy in the ISM (Industrial, Scientific, Medical)
band. Make sure that all medical devices used in proximity to this device
meet appropriate susceptibility specifications for this type of RF energy.
This product contains parts that can be damaged by electrostatic
discharge (ESD). Use ESD prevention measures to avoid damage.
To prevent water intrusion, make sure that the unit is installed with the
connectors on the bottom panel of the unit facing down.
2.2 Intended Use
The intended use of this equipment is as a communication interface and
gateway. The equipment receives and transmits data on various physical levels
and connection types.
If this equipment is used in a manner not specified by the manufacturer, the
protection provided by the equipment may be impaired.
Anybus®WLAN Access Point IP67 Startup Guide SP2383 1.3 en-US

Safety 5 (18)
2.3 5 GHz Transmission Power Restriction (EU only)
Transmission power must be reduced for 5 GHz channels 149-165 when
the unit is used in the EU.
To comply with the European Radio Equipment Directive (RED) the effective
radiated power output for 5 GHz channels 149-165 (U-NII-3) must not exceed
25 mW (~14 dBm) when the unit is used in the EU.
To configure the unit for use within the EU, set Tx Power to 14 dBm or less on
the Wireless 1 Options page of the web configuration interface.
Fig. 1 Wireless Settings
Anybus®WLAN Access Point IP67 Startup Guide SP2383 1.3 en-US

Installation 6 (18)
3 Installation
The Anybus WLAN Access Point IP67 can be screw-mounted onto a stable flat
surface using the included wall mounting kit. It can also be pole-mounted using
the included adjustable steel band straps.
For optimal reception, wireless devices require a zone between them clear of
objects that could otherwise obstruct or reflect the signal. A minimum distance
of 50 cm between the devices should also be observed to avoid interference.
Make sure that you have all the necessary information about the capabilities
and restrictions of your local network environment before installation.
Package Contents
After unpacking the access point, check the contents to be sure you have
received all the components:
• Anybus WLAN Access Point IP67 (1 x)
• Wall mounting kit (1 x)
– Mounting plate (1 x)
– Screw 5.8 mm x 14.8 mm for fixed mounting plate (4 x)
– Screw 6.3 mm x 25.3 mm for wall mount (4 x)
• Steel band strap (2 x)
• Antenna (2 x)
• Grounding cable (1x)
• Grounding screw with washer (2x)
• Startup Guide (1 x)
Anybus®WLAN Access Point IP67 Startup Guide SP2383 1.3 en-US

Installation 8 (18)
3.2 Wall Mounting
Fig. 3 Wall mounting
1. Attach the mounting plate to the back of the unit using the 4 included
screws. The plate can be attached vertically or horizontally.
2. Hold the unit upright against the wall and fasten it with 4 screws through
the apertures in the plate.
Anybus®WLAN Access Point IP67 Startup Guide SP2383 1.3 en-US

Installation 9 (18)
3.3 Pole Mounting
Fig. 4 Pole mounting
1. Attach the mounting plate to the back of the unit using the 4 included
screws. The plate can be attached vertically or horizontally.
2. Thread the two supplied metal mounting straps through the large slots on
the mounting plate and then put the straps around the pole.
To prevent water intrusion, make sure that the unit is installed with the
connectors on the bottom panel of the unit facing down.
Anybus®WLAN Access Point IP67 Startup Guide SP2383 1.3 en-US

Installation 10 (18)
3.4 Power Connector (M12)
The power connector is a 5-pin A-coded M12 type connector that supports dual
power inputs with a common ground connection.
Connecting power with reverse polarity or using the wrong type of power
supply may damage the equipment. Make sure that the power supply is
correctly connected and of the recommended type.
See also Technical Data, p. 15 regarding power supply requirements.
Pin Function
V1+ Power Input 1 +
V1- Power Input 1 -
V2+ Power Input 2 +
V2- Power Input 2 -
Power Ground
Anybus®WLAN Access Point IP67 Startup Guide SP2383 1.3 en-US

Installation 11 (18)
3.5 Ethernet Connector (M12)
The Ethernet connector is an 8-pin A-coded M12 type connector. The Ethernet
port supports PoE (Power over Ethernet) compliant with IEEE 802.3af.
A Power over Ethernet power source is not included with the equipment.
The power source must be UL (UL 62368-1) certified for UL compliance,
fully compliant with IEEE 802.3af, marked “Limited Power Source”, “LPS”
or “Class 2”, and have a rated voltage of 48 VDC and output meeting ES1
(SELV) and PS2.
See also Technical Data, p. 15 regarding power supply requirements.
Pin Function
1 BI_DC+
2 BI_DD+
3 BI_DD-
4 BI_DA-
5 BI_DB+
6 BI_DA+
7 BI_DC-
8 BI_DB-
Anybus®WLAN Access Point IP67 Startup Guide SP2383 1.3 en-US

Installation 12 (18)
3.6 Ethernet Cabling
When planning a cable route from the access point (outdoors) to the power
injector module (indoors), consider the following guidelines:
• Determine a building entry point for the cable.
• Determine if conduits, bracing, or other structures are required for safety
or protection of the cable.
• For lightning protection at the power injector end of the cable, consider
using a lightning arrestor immediately before the cable enters the building.
• Power cable and Ethernet cable are not included with the unit. The cables
and connectors must be waterproof and installed by a professional.
3.7 Grounding
When connecting a ground wire to the Anybus WLAN Access Point IP67, use the
grounding screw on the unit. Use #20 AWG or larger copper core ground wire.
The ground wire can be connected to a point on the bracket, pole, metal
grounding plate, or directly to an earth termination. Make sure that there is a
good electrical connection between the ground wire and the grounding point
(no paint or isolating surface treatment).
Anybus®WLAN Access Point IP67 Startup Guide SP2383 1.3 en-US

Installation 13 (18)
3.8 LED Indicators
Fig. 5 LED indicators on bottom panel
PWR1 Green Power supplied on Power Input 1
PWR2 Green Power supplied on Power Input 2
PoE Green Power supplied on Ethernet port
ETH
Off No LAN
Green LAN link established
Green, flashing LAN traffic
WLAN
Off No WLAN
Green WLAN link established
Green, flashing WLAN traffic
Anybus®WLAN Access Point IP67 Startup Guide SP2383 1.3 en-US

Configuration 14 (18)
4 Configuration
Anybus WLAN Access Point IP67 is configured via a web interface which is
accessed by pointing a web browser to the IP address of the unit. The computer
accessing the web interface must be in the same IP subnet as the access point.
Default web interface settings
IP address 192.168.0.2
User ID admin
Password admin
See the Anybus WLAN Access Point IP67 User Manual for more information
about how to configure the access point.
4.1 Factory Reset
Fig. 6 Reset
To restore the factory default settings, press and hold RESET on the front panel
until the power LED indicator(s) starts to flash, then release the button.
Anybus®WLAN Access Point IP67 Startup Guide SP2383 1.3 en-US

Technical Data 15 (18)
5 Technical Data
5.1 Technical Specifications
Order code AWB4004
Wireless antenna External (N-type)
Wired interface Ethernet
Ethernet port 10/100/1000Base-T(X) Auto MDI/MDX
M12 8-pin female A-coded connector
Power connector M12 5-pin female A-coded connector
(dual power inputs in single connector)
Power supply 2 x 12–48 VDC
Power over Ethernet 44–57 VDC DTE Type1 according to IEEE 802.3af
Current consumption Max. 0.75 A @ 12 VDC (9 W)
Dimensions (WxHxD) 310 x 87 x 310 mm
Weight 2.56 kg
Operating temperature -25 to +70 °C
Storage temperature -40 to +85 °C
Humidity 5 % to 95 % non-condensing
Mounting Wall mount or pole mount
Housing Metal
Protection class IP67
Certifications See datasheet
For more technical details and specifications, visit www.anybus.com/support.
Disposal and recycling
You must dispose of this product properly according to local laws
and regulations. Because this product contains electronic
components, it must be disposed of separately from household
waste. When this product reaches its end of life, contact local
authorities to learn about disposal and recycling options, or simply
drop it off at your local HMS office or return it to HMS.