Holley LoRaWAN DTZ541-ZDBL User manual

Contents
1 Notice.........................................................................................................................................1
2 Preface........................................................................................................................................2
3 General.......................................................................................................................................4
3.1 Device versions................................................................................................................4
3.2 Housing element ..............................................................................................................5
3.3 Nameplate........................................................................................................................6
4 Technical Data............................................................................................................................7
4.1 Test-LED.........................................................................................................................8
4.2 Notes on measurement accuracy.......................................................................................8
5 Assembly....................................................................................................................................9
5.1 Attachment and connection ..............................................................................................9
5.2 Rates control....................................................................................................................9
5.3 Terminal block...............................................................................................................10
6 LC-Display...............................................................................................................................12
6.1 LCD- Segments..............................................................................................................12
6.2 Display of operation.......................................................................................................13
7 PIN...........................................................................................................................................15
7.1 INFO PIN ......................................................................................................................15
7.2 MSB PIN.......................................................................................................................16
7.3 LMN PIN.......................................................................................................................17
8 Tariff control ............................................................................................................................18
8.1 Configuration of the dual tariff function .........................................................................18
8.2 LMN command for tariff switching................................................................................18
9 Operation of the counter with the key........................................................................................20
10 LoRaWAN Function...............................................................................................................27
10.1 Meter Reading Message (MRM)...................................................................................27
10.1.1 Meter Reading Message Header (MRMHDR) is defined as:.........................27
10.1.2 HEX-Code conversion.................................................................................28

User Manual LoRaWAN mME DTZ541 Three-phase electricity meter
3/ 35
10.2 Meter Control Message (MCM)....................................................................................29
10.2.1 Meter Control Message (MCMHDR) defined as: .........................................30
10.2.2 Unconfirmed Interval...................................................................................30
10.2.3 Confirmed Interval ......................................................................................31
10.2.4 Max Wiederholungen ..................................................................................31
10.2.5 Example......................................................................................................31
11 LoRa Function..............................................................................................................32

User Manual LoRaWAN mME DTZ541 Three-phase electricity meter
1/ 31
1 Notice
Safety Instructions
The installation, installation and uninstallation of the meter may only be carried out by a certified electrician. For
your own safety and to avoid damage to the device, please observe the following safety information. The information
in the manual is important for your own safety in order to avoid damage. Please also comply with the generally
applicable local safety regulations for electrical installations
Danger!
Improper handling of live parts can lead to life-threatening injuries and accidents.
Before starting the installation, the power must be switched off for the main circuit
breaker. Incorrect labeling of fuses or circuit breakers can lead to the inadvertent
shutdown of the wrong system. This would mean that the system being worked on
would continue to be live. A suitable measuring device is used to check that there
is no voltage.
Guarantee Notice
Damage to the meter may only be repaired by the manufacturer. The meter may not be repaired
yourself if it is damaged. Claims under the guarantee can only be asserted if the prerequisite is that the
meter is not opened and / or the seal is undamaged. All guarantee and warranty rights expire when the
device is opened. The same applies to damage caused by external influences
The meter is maintenance-free.
Disclaimer
This description was created to the best of our knowledge and belief. The data in this manual are
checked regularly and necessary corrections are included in the subsequent revisions.

User Manual LoRaWAN mME DTZ541 Three-phase electricity meter
2/ 31
2 Preface
LoRaWAN mME DTZ541, it is a new innovative product that was developed for the German market.
The meter has 2 communication channels "LoRaWAN" and "LoRa". With the LoRaWAN network,
the meter can regularly send the defined measurement data to the server. In addition, the user can use
a LoRa adapter to query all measurement data from the meter at any time and also set all parameters.
As the "modern measuring device", the meter meets all legal requirements as well as standards and
normative documents. The main ones are listed in the following table:
Norm
Explanation
IEC 62052-11
AC electricity meters - General requirements, tests and test conditions - Part
11: Measuring devices
IEC 62053-21
AC Electricity Meter - Special Requirements. Part 21: Electronic active
consumption meters of accuracy classes 1 and 2
IEC 62056-21
Electricity metering - Data exchange for meter reading, tariff and load control -
Part 21: Direct local data exchange
SML 1.04
SML –Smart Message Language
EN 50470-1
AC electricity meter; General requirements, tests and test conditions -
measuring equipment (accuracy classes A, B andC); German version
EN50470-1: 2006 Correction to DIN 50470-1 (VDE 0418-0-1): 2007-05
EN 50470-3
ALTERNating current electricity meter; Special requirements - Electronic
power consumption counters (accuracy classes A, B and C); German version
EN 50470-3:2006
DIN 43857-2
Electricity meter in insulating housing for direct connection up to 60 A limit
current Main dimensions for three-phase meters
EN 60999-1
Connection material - Electric copper conductors; Safety requirements for
screw terminals and screwless terminal points - Part 1: General requirements
and special requirements for terminal points for conductors from 0.2 mm2up to
and including 35 mm2
Richtlinie
2014/32/EU
DIRECTIVE 2014/32 / EU OF THE EUROPEAN PARLIAMENT AND OF
THE COUNCIL of February 26, 2014 on the harmonization of the laws of the
member states regarding the making available of measuring instruments on the
market
Lastenheft
Funktionale
Merkmale
VDE / FNN instructions, specifications for basic meter functional features,
version 1.3 (11/2016)

User Manual LoRaWAN mME DTZ541 Three-phase electricity meter
3/ 31
Lastenheft
EDL
VDE / FNN specifications EDL electronic household meters, functional
features and protocol, version 1.2 (11/2016)

User Manual LoRaWAN mME DTZ541 Three-phase electricity meter
4/ 31
3 General
3.1 Device versions
This chapter lists options for the DTZ541 type electricity meter. These options then map a complete
type designation of the meter. The individual meter can be defined by specific, clear characteristics
such as maximum electricity, the tariff or the data interface. With the additional type number you can
fully define the version of the DTZ541 three-phase energy meter.
DTZ541
-
*
*
*
*
1
2
3
4
5
The type of current direction is permanently configured as the factory setting and may no longer be
changed during use. The double tariff function can be set in the same way as other functions specified
in the FNN specification sheet for basic meters. The measuring device user can activate or deactivate
via the LMN interface with the communication adapter "BAB-01".
Nr.
Norm
Explanation
1
Three-phase electricity
meter
DTZ541: Design
2
Current direction
B: Reference counter with backstop
L: Delivery counter with backstop
Z: Bidirectional counter
S: Delivery counter, balancing without backstop
3
Rates
D: Double rates
E: Single rate
4
MSB- PIN
B: RS485
C: RS232
5
Accuracy
A: class A
B: class B
L: LoRaWAN + class A

User Manual LoRaWAN mME DTZ541 Three-phase electricity meter
5/ 31
3.2 Housing element
Nr.
Explanation
Nr.
Explanation
1
LED Pulse output
6
Control button for switching the
display and entering the PIN
2
Optional extension of the upper
attachment
7
Sealable housing cover
3
Two-line display
8
User security can be secured with a
wire seal
4
Housing cover protection under
calibration law
9
Terminal cover
5
INFO customer PIN

User Manual LoRaWAN mME DTZ541 Three-phase electricity meter
6/ 31
3.3 Nameplate
Nr.
Explanation
Nr.
Explanation
1
LED- Pulse constant
2
Logo from manufacturer
3
AC electricity meter
4
Three-phase four-wire meter
5
Protection class III
6
Information on the type of measurement
7
operation manual
8
Temperature range
9
Circuit diagram
10
Construction year
11
Manufacturer's address
12
Unique identification number according to
DIN 43863-5
13
Server ID
14
Measurement accuracy
15
Connection conditions
16
Material number by the customer
17
Design
18
Number of the EC-type examination certificate
19
CE- Conformity mark
20
OBIS Code and register

User Manual LoRaWAN mME DTZ541 Three-phase electricity meter
7/ 31
4 Technical Data
Features
Explanation
Connection type
Dreiphasen-Vierleiter / Einphasen-Wechselstrom
frequency
50Hz
Rated voltage
3 * 230/400 V
1*230V auf L1, L2, L3
Current Imin-Ib(Imax)
0,25-5(100) A or 0,25-5(60) A
Starting current
0.004*Ib=0,02 A
Transient current (Itr)
10%*Ib=0,5 A
Surge voltage resistance
6 kV, IEC 62052-11
Short-circuit strength
30Imax, IEC 62053-21
Power consumption
Current path: <0,2VA
Voltage path: <0,5W
Measurement accuracy
Class A (EN50470-1-3) or
Class2.0 (IEC62053-21)
LED pulse output
500 or 5 000 or 10 000 Imp/kWh
Metrology
Current direction +A: (Single rate) only 1.8.0;
(Double rate) Change between1.8.1 and 1.8.2 Current direction-
A: 2.8.0
(Double rate) Substitution between 2.8.1 and 2.8.2
External rates switching
control (with double rate
meters)
Clamp 13 u. 15
LC-Display
Format: Two lines
Viewing angle: 15° (from above) and 60° (from left, right, down)
Digit dimensions in the range of values: 3,5mm * 8mm (min.)
Digit dimensions in the code area: 1,9mm * 4,2mm (min.)

User Manual LoRaWAN mME DTZ541 Three-phase electricity meter
8/ 31
Features
Explanation
Mechanical environmental
conditions
M1
Electromagnetic
environmental conditions
E2
Protection class
IP51
Relative humidity
95% non-condensing, <75% annual mean according to
IEC 62052-11, EN 50470-1 and IEC 60068-2-30
Temperature range
-25 ° C ... + 55 ° C (operation)
-40 ° C ... + 70 ° C (storage)
lifespan
20 years
User protection
2 security options for seal
Terminal block
DIN 43857 part 2
Clamps ∅
9,5mm
casing material
Glass fiber reinforced polycarbonate
Size
290,5 mm (L) * 170 mm (W) * 52,5 mm (H)
Weight
720g
4.1 Test-LED
The test LED of the DTZ541 illuminates the infrared light. It is used to output energy-proportional
active energy pulses and to display start-up and idling. When idling, the test LED lights up
continuously. If the meter measures above its start-up threshold, the energy-proportional pulses are
displayed. The accuracy of the DTZ541 is determined by the LED pulse outputs.
4.2 Notes on measurement accuracy
Only the specified meter types with the associated software version numbers are permitted for use of
the LMN interface in accordance with calibration law. For this purpose, the respective approved
software versions must be observed. The measured value data have a resolution of 4 decimal places.
All parties involved must ensure that the requirements from PTB-A 50.8, Appendix A3 for latency
times and applicable tariff application cases are complied with, also taking into account several
communication adapters connected to a smart meter gateway.

User Manual LoRaWAN mME DTZ541 Three-phase electricity meter
9/ 31
5 Assembly
5.1 Attachment and connection
Before installing and commissioning the meter, check whether the meter is damaged. please check whether the
meter is damaged. If you detect any damage to the housing or a missing legal metrological fuse, the meter must not
be used if the seals are missing or the housing is damaged. The DTZ541 three-phase energy meter is suitable for
mounting on a meter position in accordance with DIN VDE 0603-2-1, three-point attachment DIN 43857-2 and
should be connected according to the circuit diagram.
Dimension
Double rates(DIN 43856 Schltg.: 4101MME) Single rates(DIN 43856 Schltg.: 4000MME)
5.2 Rates control
The rates control is carried out regulated by potential-free rates control terminals 13 and 15. With the
double rates meter, the rates can be switched by activating the terminals with system voltage by a
rates control device. Without control,rates 2 is active. rate T1 is activated when voltage is applied to
terminal 13.

User Manual LoRaWAN mME DTZ541 Three-phase electricity meter
10 / 31
5.3 Terminal block
In order to ensure asecure electrical connection between connecting cables and terminals, the clamping
screws must be tightened with a corresponding torque in accordance with DIN EN 60999-1. Tighten
the terminal screws with a corresponding torque in accordance with DIN EN 60999-1 to ensure a safe
electrical connection between the connecting cables and to ensure the terminals. The meter has tinned
copper shunts and can be contacted directly on copper or aluminum lines. The suitability of the meter
for connection is indicated on the meter.
Variant 60A (cage terminal block)
Variant 100A

User Manual LoRaWAN mME DTZ541 Three-phase electricity meter
11 / 31
Variant 60A/100A
Phase Clamps
1, 3, 4, 6, 7, 9, 10, 12
Voltage /
N tap
2, 11
Additive -
Clamps
13, 15, 27, 28
Clamps ∅(mm)
9,5
3,0
3,0
Min. Connection cross-sections
(mm²)
6
1,5
1,5
Max. Connection cross-sections
(mm²)
35
2,5
2,5
Prescribed tightening torque (Nm)
1,5…2,5
0,5
0,5
Kopf
PZ2
Kreuzschlitz
Kreuzschlitz
Thread size
M6
M3
M3

User Manual LoRaWAN mME DTZ541 Three-phase electricity meter
12 / 31
6 LC-Display
6.1 LCD- Segments
The meter has an LC display with additional symbols to identify measured values and working
conditions.
Nr.
Explanation
1
Active tariff display
2
OBIS code of the labor value
3
Display of meter reading
4
Unit for meter reading
5
Phase control
6
Energy direction
7
Direction of flow of the measured energy
8
simulates carrier
9
Unit for voltage, current or apparent power
10
Symbol for communication via the electrical data interface
11
Unit for performance or historical values

User Manual LoRaWAN mME DTZ541 Three-phase electricity meter
13 / 31
12
Display of current performance or info
13
Abbreviation of "Day" for historical values
14
Information content icon
15
Info display icon
6.2 Display of operation
The display test for 15 seconds when the voltage is restored. Upper display line segments and lower display line
segments alternately fade in and out 3 times.
The software version number of the metrological part is shown on the display with the associated checksum. The
software version is indicated with index 1.
If a communication adapter "BAB-01" is connected, the display then shows its software version number and the
associated checksum. The software version is indicated with index 2.
Rolling display of billing-relevant values. The display of the instantaneous power in the second line must be
enabled by entering a PIN:

User Manual LoRaWAN mME DTZ541 Three-phase electricity meter
14 / 31
Variant of single tariff for current direction + A: only register 1.8.0
Double tariff variant for current direction + A: alternating display between registers 1.8.1 and 1.8.2
Variant of individual tariff for current direction -A: only register 2.8.0
Double tariff variant for current direction -A: alternating display between registers 2.8.1 and 2.8.2
The 6 register values 1.8.0, 1.8.1, 1.8.2, 2.8.0, 2.8.1 and 2.8.2 are relevant for billing. They are always shown in the
same way as the variant in the first line of the display and only kWh without decimal places.
After entering the PIN, all the values shown in the second line are for customer information only and may not be
used for billing-related purposes. This applies in particular to the instantaneous power, the historical consumption
values (1d, 7d, 30d, 365d), as well as consumption values since zero setting.
If an error is detected which means that the measured values can no longer be used for accounting, the display shows
this message for 2 seconds after each partial step of the information to be displayed on a rolling basis.

User Manual LoRaWAN mME DTZ541 Three-phase electricity meter
15 / 31
7 PIN
7.1 INFO PIN
An optical data interface on the front is available forthe enduser. Its constant data rate is 9600 baud andthe character
encoding is 8-N-1. The transmission protocol is according to SML specification version 1.04. The interfaces work in
"PUSH" mode and send out one data record every second. The data has 3 variants. If you do not enter a PIN for the
"INFO OFF" setting, it is the "Reduced data record", otherwise it is the "Complete data record". The “manufacturer-
specific data record” can also be activated or deactivated via the rear interface.
Record to the INFO-PIN
Reduced data set
Complete data set
Manufacturer-specific data
record
•Manufacturer ID
•Device identification
•Meter reading + A, tariff-
free (without decimal
places, only for single-
tariff meters)
•Meter reading + A, tariff 1
(without decimal places,
only for two-tariff meters)
•Meter reading + A, tariff 2
(without decimal places,
only for two-tariff meters)
•Meter reading -A, tariff-
free (without decimal
places, only for single-
tariff meters)
•Meter reading -A, tariff 1
(without decimal places,
only for two-tariff meters)
•Meter reading -A, tariff 2
(without decimal places,
only for two-tariff meters)
•Manufacturer ID
•DeviceIdentification
•Meter reading + A,
tariff-free (only with
one-tariff meter)
•Meter reading + A,
tariff 1 (only for two-
tariff meters)
•Meter reading + A,
tariff 2 (only for two-
tariff meters)
•Meter reading -A,
tariff-free (only with
single-tariff meters)
•Meter reading -A,
tariff 1 (only for two-
tariff meters)
•Meter reading -A,
tariff 2 (only for two-
tariff meters)
•Current total active
power with sign
•Manufacturer ID
•Device identification
•Meter reading + A, tariff-free
(only with one-tariff meter)
•Meter reading + A, tariff 1
(only for two-tariff meters)
•Meter reading + A, tariff 2
(only for two-tariff meters)
•Meter reading -A, tariff-free
(only for single-tariff meters)
•Meter reading -A, tariff 1 (only
for two-tariff meters)
•Meter reading -A, tariff 2 (only
for two-tariff meters)
•Current total active power with
sign
•Active power L1
•Active power L2
•Active power L3
•Voltage L1
•Voltage L2

User Manual LoRaWAN mME DTZ541 Three-phase electricity meter
16 / 31
•Firmware version
•Firmware checksum
•Error register
•Voltage L3
•Current L1
•Current L2
•Current L3
•Phase angle U-L2 to U-L1
•Phase angle U-L3 to U-L1
•Phase angle I-L1 to U-L1
•Phase angle I-L2 to U-L2
•Phase angle I-L3 to U-L3
•frequency
•Historical consumption value
"1d" without previous values
•Historical consumption value
"7d" without previous values
•Historical consumption value
"30d" without previous values
•Historical consumption value
"365d" without previous values
•Historical consumption value
since the last reset
•Firmware version
•Firmware checksum
•Error register
7.2 MSB PIN
DTZ541 has an MSB interface from terminals 27 and 28. Its constant data rate is 9600 baud and the
character coding is 8-N-1. The transmission protocol is RS485 according to SML specification version
1.04. The interfaces work in "PUSH" mode and send out a manufacturer-specific data record every
second.

User Manual LoRaWAN mME DTZ541 Three-phase electricity meter
17 / 31
7.3 LMN PIN
The MSB interface can be expanded as the LMN interface with the Holley communication adapter
BAB-01. Its constant data rate is 1Mbit and the character encoding is 8-N-1. The LMN interface meets
the requirements of the FNN specification sheet for basic meters, the PTB requirements for
communication adapters PTB-A50.8 and the requirements of BSI TR03109. This LMN interface can
communicate directly with SMGw.
Table of contents
Other Holley Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

Minebea
Minebea CSD-401 instruction manual

Team
Team SWR-1180 KA Operating instruction

Gill Instruments
Gill Instruments R3-50 user manual

Badger Meter
Badger Meter ORION installation manual

S+S Regeltechnik
S+S Regeltechnik RHEASPEG KLSW Series Operating Instructions, Mounting & Installation

COM-power corporation
COM-power corporation FCLC-400 instruction manual