manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Holmes
  6. •
  7. Humidifier
  8. •
  9. Holmes HM1895 User manual

Holmes HM1895 User manual

STORAGE INSTRUCTIONS
REPLACEMENT ACCESSORIES
TROUBLESHOOTING
FREQUENTLY ASKED QUESTIONS
PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS
Owner’s Guide
HM1895
WARRANTY INFORMATION
Cool Mist
Humidifier
☎INFO HOT-LINE: If, after reading this owner’s guide you have
any questions or comments, please call 1-800-546-5637 and a
Customer Service Representative will be happy to assist you.
STORAGE INSTRUCTIONS
When not using your humidifier for an extended period of time:
1. Dispose of the filters. DO NOT leave in unit.
2. Clean, rinse and thoroughly dry the humidifier as directed in weekly maintenance. DO NOT leave any water in
the unit when storing. Leaving water in the unit may render the unit inoperable for the following season.
3. Place the humidifier in the original carton and store in a cool, dry place.
4. Order your replacement filter for next year’s use.
REPLACEMENT ACCESSORIES
To order the replacement accessories you can do any of the following:
• Visit your local retailer
• Go to www.holmesproducts.com
• Call consumer service at 1-800-546-5637
FILTER# : HWF65CS / HF206
FILTER TYPE: WICK
FREQUENTLY ASKED QUESTIONS
QUESTIONS ANSWER
The estimated run time for this humidifier is based on average room conditions. The
actual run time of your humidifier is dependent on numerous variables such as:
1. Air exchange in the room where the humidifier is placed.
2. Room construction where the humidifier is placed.
3. Temperature of the room where the humidifier is placed.
4. Humidity levels in the room where the humidifer is placed.
5. Movement of occupants and the opening and closing of doors in the room where
the humidifier is placed.
6. Home furnishings in the room where the humidifer is placed.
See Daily Maintenance instructions. Regular cleaning is recommended.
1. Run your unit on the lowest setting.
2. If your unit has electronics, set it to your desired humidity level. The unit will turn
on and off, which will extend the run time.
3. Fill the tank all the way full, place it on the base, let the water empty into the
base until it stops bubbling, then refill the tank full again. This ensures maximum
water capacity and will extend run time.
What are the variables that
affect run time?
How do I remove film on
water tank?
How can I extend the run
time?
© 2008 Sunbeam Products, Inc. doing business as Jarden Consumer Solutions. All Rights Reserved. Distributed by
Sunbeam Products, Inc. doing business as Jarden Consumer Solutions, Boca Raton, Florida 33431.
3 YEAR LIMITED WARRANTY
Sunbeam Products, Inc. doing business as Jarden Consumer Solutions or if in Canada, Sunbeam Corporation (Canada)
Limited doing business as Jarden Consumer Solutions (collectively “JCS”) warrants that for a period of three years from
the date of purchase, this product will be free from defects in material and workmanship. JCS, at its option, will repair
or replace this product or any component of the product found to be defective during the warranty period. Replacement
will be made with a new or remanufactured product or component. If the product is no longer available, replacement
may be made with a similar product of equal or greater value. This is your exclusive warranty. Do NOT attempt to repair
or adjust any electrical or mechanical functions on this product. Doing so will void this warranty.
This warranty is valid for the original retail purchaser from the date of initial retail purchase and is not transferable.
Keep the original sales receipt. Proof of purchase is required to obtain warranty performance. JCS dealers, service centers,
or retail stores selling JCS products do not have the right to alter, modify or any way change the terms and conditions of this
warranty.
This warranty does not cover normal wear of parts or damage resulting from any of the following: negligent use or
misuse of the product, use on improper voltage or current, use contrary to the operating instructions, disassembly, repair
or alteration by anyone other than JCS or an authorized JCS service center. Further, the warranty does not cover: Acts
of God, such as fire, flood, hurricanes and tornadoes.
What are the limits on JCS’s Liability?
JCS shall not be liable for any incidental or consequential damages caused by the breach of any express, implied or
statutory warranty or condition.
Except to the extent prohibited by applicable law, any implied warranty or condition of merchantability or fitness for a
particular purpose is limited in duration to the duration of the above warranty.
JCS disclaims all other warranties, conditions or representations, express, implied, statutory or otherwise.
JCS shall not be liable for any damages of any kind resulting from the purchase, use or misuse of, or inability to use the
product including incidental, special, consequential or similar damages or loss of profits, or for any breach of contract,
fundamental or otherwise, or for any claim brought against purchaser by any other party.
Some provinces, states or jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or
limitations on how long an implied warranty lasts, so the above limitations or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from province to province,
state to state or jurisdiction to jurisdiction.
How to Obtain Warranty Service
In the U.S.A.
If you have any question regarding this warranty or would like to obtain warranty service, please call 1-800-546-5637
and a convenient service center address will be provided to you.
In Canada
If you have any question regarding this warranty or would like to obtain warranty service, please call 1-800-546-5637
and a convenient service center address will be provided to you.
In the U.S.A., this warranty is offered by Sunbeam Products, Inc. doing business as Jarden Consumer Solutions located
in Boca Raton, Florida 33431. In Canada, this warranty is offered by Sunbeam Corporation (Canada) Limited doing
business as Jarden Consumer Solutions, located at 20 B Hereford Street, Brampton, Ontario L6Y 0M1. If you have any
other problem or claim in connection with this product, please write our Consumer Service Department. PLEASE DO
NOT RETURN THIS PRODUCT TO ANY OF THESE ADDRESSES OR TO THE PLACE OF PURCHASE.
9100030005447 HM1895UC08EM2 Printed in China
If you have any questions regarding your product or would like to learn more about other Holmes®products, please
contact our Consumer Service Department at 1-800-546-5637 or visit our website at www.holmesproducts.com.
TROUBLE
Unit does not turn on
Mist output minimal to none
Filter turns brown
FilterCheck®is not working
Humidifier continuously displays 21%
Humidifier continuously displays 90%
PROBABLE CAUSE
Not plugged in. Humidistat is set too low
Mist is invisible. Filter has not
absorbed water
The filter has absorbed minerals
Takes 60 minutes to register
Humidity at the humidifier is at or
below 21%
Humidity at the humidifier is at or
above 90%
SOLUTION
Plug in unit. Set humidistat to high
Wait 30 minutes for filter to absorb water
Replace your filter (HWF65CS/HF206)
by calling 1-800-546-5637, or
visiting
www.holmesproducts.com
Allow the humidifier to run
continuously for 60 minutes for the
FilterCheck®Indicator to reflect the
filter condition
Continue to operate humidifier to raise
the room humidity
Stop operating the humidifier if the
humidity level is too high
HM1895-UC_08EM2.qxd:9100030005294 5/28/08 10:38 AM Page 1
5. To stop the unit, press and hold the button for two
seconds, or keep pressing the button until the display
reads OFF (OF).
AccuSet Plus™ HUMIDISTAT INSTRUCTIONS
To take advantage of the AccuSet Plus™ Digital Humidistat,
press the MODE/OFF button (Mode / ) until the speed is
set in either the auto HIGH (A3), auto MEDIUM (A2) or auto
LOW (A1) setting. Then adjust the set humidity by using the
up and down buttons. Humidity will increase or decrease in
increments of 5%. When the humidity level is set, the
display will return to show the current room humidity. When
the room humidity level rises above the set humidity, the
humidifier will stop. When the humidity level drops below
the set humidity, the humidifier will turn on automatically.
NOTE: Allow up to 30 minutes for the filter to fully
absorb water and for the unit to produce moisture.
NOTE: The AccuSet Plus™ Humidifier has memory. This
means that when you turn the unit back on, it will be at
the last setting the humidifier was set at.
If you do not plan to use the humidifier for two or more
days, make sure any residual water is drained from the
water tank, base and wick filter to prevent algae or
bacteria growth.
Extended Run Time Setting:
By setting you humidifier to a specific humidity level, you
are actually also extending the run time. Since the unit will
turn on and off to maintain the set humidity level, less
water will be used than on manual setting, so you will need
to fill the unit less than you would on manual setting.
16 HOUR AUTO ON/OFF TIMER
INSTRUCTIONS
The Auto On/Off timer will allow the user two options, to
set a time to turn the unit off or to set a time to turn the
unit on.
Auto Off Timer
While the unit is running, the off timer can be activated by
holding down the up and down buttons simultaneously for
2 seconds, the screen will flash 00 and the up and down
arrows can be pushed to adjust the timer up to 16 hours in
increments of one, once 16 hours is reached, the next push
of the timer button will cycle back to 00 hours. The Timer
Light ( ) will illuminate when the Timer is set. The unit
will then shut off after the timer expires (in its current
setting). While the unit is running, the timer should stay on
even if other modes are being changed. The timer should
only be deactivated if the unit is turned off.
Auto On Timer
While the unit is off, the up and down buttons are pressed
simultaneously for 2 seconds and the display will flash 00
the up button may then be pushed again to increase the
hours to turn on (in its last setting) from 1-16 in
increments of 1 hour. The unit will then come on after the
timer expires, if the unit is then turned on, the timer will
be deactivated. The Timer Light ( ) will illuminate when
the Timer is set. Once 16 hours is reached, the next push
of the timer button will cycle back to 00 hours .
REPLACING THE FILTERS
Through normal use, waterborne minerals and sediment
become trapped in the wick filter. The harder your water, the
greater the amount of minerals in the water, and the more
often you will need to change your filter.
You will be able to monitor the life of the filter in your
humidifier by checking the FilterCheck®Indicator. The
FilterCheck®Indicator will only read the filter condition
when the humidifier is in operation.
NOTE: It may take up to 60 minutes of operation for the
FilterCheck®Indicator to reflect the filter condition.
A brand new filter will register in the section reading GOOD
filter. After frequent use of your humidifier, the FilterCheck®
Indicator will let you know when the filters need to be
changed, see Figure 2.
When the needle is in the
CHANGE section, this means
the proper amount of
moisture is not getting into
your air due to the excessive
minerals and sediment that
have become trapped on your
filters. At this point, you should replace your filter. It is
important to change your filter as indicated to obtain
stated performance level.
To replace the filter, follow the steps below:
1. Turn the unit off and disconnect from the electrical outlet.
2. Remove the tank and main housing to access the base tray.
3. Remove wick and discard.
4. Follow the weekly cleaning instructions.
5. Insert new filter.
6. Repeat Operating Instructions steps.
It will take about 30 minutes for the humidifier to reach
maximum output.
You can purchase replacement filters (model HWF65/
HF206) at a local retailer, by calling 1-800-546-5637, or
by visiting www.holmesproducts.com. It is recommended
that a replacement filter is purchased for uninterrupted
use.
CLEANING AND MAINTENANCE
INSTRUCTIONS
Humidifiers provide comfort by adding moisture to dry,
heated indoor air. To benefit most from the humidifier and
avoid product misuse, follow all instructions carefully. Please
note that this is an electrical appliance and requires attention
when in use.
In addition, if you do not follow the recommended care
and maintenance guidelines, micro-organisms may be
able to grow in the water within the water tank. You must
routinely follow the cleaning procedures that follow in
order to ensure proper, efficient operation of your
humidifier. Proper maintenance and cleaning is essential
to the continued performance of your unit and the
avoidance of algae or bacteria build-up.
DAILY MAINTENANCE
1. Be sure the unit is OFF and is disconnected from the
electrical outlet.
2. Remove the housing and the tank from the
humidifier and place in sink or tub.
3. Carry the base of the unit to the sink, remove the
wick, place in sink, drain any remaining water and
rinse thoroughly to remove any sediment or dirt.
Wipe clean, and dry with a clean cloth or paper towel.
4. Drain the water from the tank into the sink and rinse
tank thoroughly. Wipe clean, and dry with a clean
cloth or paper towel.
5. Put filter back in, replace the housing, then refill tank
with cool tap water as instructed earlier in the Filling
Instructions. Do not overfill.
6. Follow Operating Instructions.
WEEKLY MAINTENANCE
To Remove Scale:
1. Repeat steps 1-4 above.
2. Clean the base by partially filling the base with one
8-oz cups of undiluted white vinegar, or by using
Cleanse Clean®Solution (Model S1710) by the
manufacturer. Leave this solution in the base for 20
minutes, while cleaning all the interior surfaces with
a soft brush. Remove base scale by wiping the base
with a cloth dampened with undiluted white vinegar.
3. Rinse with clean warm water to remove the cleaning
solution before disinfecting the tank.
To Disinfect Humidifier Base and Tank:
1. Fill humidifier base with 1/4gallon of water and 1/2
teaspoon of chlorine bleach.
2. Fill the tank 1/2full with water and 1/2teaspoon of
chlorine bleach.
3. Let the solution stand for 20 minutes, swishing every
few minutes. Wet all surfaces.
4. Carefully empty the base and tank after 20 minutes,
and rinse with water until you cannot detect any
bleach smell. Dry with a clean cloth or paper towel.
5. Check the FilterCheck®Indicator to see if it is time to
replace the filter. Depending on water hardness in your
area, it may be necessary to change the filter every 1-
2 months. Reinsert the wick filter into the base.
6. Refill the water tank as directed with cool tap water,
replace the humidifier housing, and turn the unit on.
23. Do not pour water in any openings other than the
water tank.
24. To prevent damage to surfaces, do not place
humidifier under overhanging surfaces.
25. NEVER operate unit without water in the tank.
26. Do not move unit after it has been used until unit
cools completely.
27. Use both hands when carrying full tank of water.
PLEASE READ AND SAVE
THESE IMPORTANT SAFETY
INSTRUCTIONS
Consumer Safety Information
Note: This is an electrical appliance and requires
attention when in use.
Note: If moisture forms on the walls or windows of the
room, turn off the humidifier. The room already has plenty
of humidity and additional moisture may cause damage.
Note: DO NOT block air inlet or outlet.
Cord and Plug Installation Safety Instructions
The length of cord used on this appliance was selected to
reduce the hazards of becoming tangled in, or tripping
over a longer cord. If a longer cord is necessary an
approved extension cord may be used. The electrical
rating of the extension cord must be equal to or greater
than the rating of the humidifier. (refer to the rating
artwork placed on the humidifier). Care must be taken to
arrange the extension cord so that it will not drape over
the countertop or tabletop where it can be pulled on by
children or accidentally tripped over.
HOW COOL MIST WORKS
Your Holmes®Cool Mist humidifier draws dry air through
the rear air intake grill area. This air is then passed
through a moisture – laden wick filter, which retains the
minerals and deposits in the water. The resulting moist air
is directed back into the room from the top air grill.
NOTE: This humidification system provides a cool,
invisible moisture output. It is normal not to see the mist.
NOTE: A humidity level below 20% can be unhealthy
and uncomfortable. The recommended humidity level is
between 40%-50%.
PRE-OPERATING INSTRUCTIONS
1. Be sure the humidifier is switched to OFF and the unit
is disconnected from the electrical outlet.
2. Select a location for your humidifier, on a flat
surface, about 4 inches (10 cm) away from the wall.
DO NOT place the humidifier on a finished floor or
near furniture, which can be damaged by moisture or
water. Place on a moisture-resistant surface.
FILLING THE WATER TANK
1. Remove the tank from the base of the humidifier and
bring to the faucet. Turn the tank upside down and
twist off the tank cap by turning counter clockwise.
Fill tank with cool, fresh tap water. DO NOT fill with
warm water as this may cause leaking. Replace the
cap on tank FIRMLY.
2. When full, carry tank to the humidifier and place
onto the base. The tank holds 2.25 gallons of water
and the base holds 1/4gallon of water. The tank will
immediately begin to empty into base.
3. Plug the power cord into a 120V AC electrical outlet.
OPERATING INSTRUCTIONS
Your humidifier is equipped with a technologically
advanced Accuset Plus™ digital Humidistat. You can set
the humidifier to run continuously in manual mode or set
the Accuset Plus™ digital Humidistat to your desired
humidity setting. The Accuset Plus™ digital Humidistat
will automatically turn the humidifier ON or OFF,
depending on the preset comfort level. The comfort level
ranges between 35% and 65% relative humidity.
Manual Mode Instructions:
1. Plug the humidifier into a 120V AC electrical outlet.
2. The display will show the current room humidity.
NOTE: The display range is 21% - 90%. If your room
humidity level falls below 21%, the unit will display 21. If
your room humidity level rises above 90%, the unit will
display 90.
3. To start the unit, push the MODE/OFF button
(Mode / ) twice within 3 seconds for the HIGH (3)
manual setting.
4. Press the button again for the MEDIUM (2) manual
setting and again for LOW (1). After the selection is
made, the display will return to show the current
room humidity.
PLEASE READ AND SAVE THESE
IMPORTANT SAFETY INSTRUCTIONS
FEATURES - OPERATIONS
When using electrical appliances, basic safety precautions
should always be followed to reduce the risk of fire, electric
shock, and injury to persons, including the following:
1. Read all instructions before using the appliance.
2. To avoid fire or shock hazard, plug the appliance
directly into a 120V AC electrical outlet.
3. Keep the cord out of heavy traffic areas. To avoid
fire hazard, NEVER put the cord under rugs or near
heat registers.
4. DO NOT place humidifier near heat sources such as
stoves, radiators, and heaters. DO locate your
humidifier on an inside wall near an electrical outlet.
The humidifier should be at least 4 inches (10 cm)
away from the wall for best results.
5. NEVER place humidifier in an area where it is
accessible to children. NEVER use humidifier in a
closed room, particularly where a child may be
sleeping, resting, or playing (a closed room may
result in excessive humidity).
6. WARNING: Do not attempt to refill humidifier
without first unplugging the unit from its electrical
outlet. Failure to heed this warning may cause
personal injury. Be sure to unplug the unit by
pulling on the plug and not the cord.
7. Never place anything over moisture outlet when the
unit is running.
8. NEVER drop or insert any object into any openings.
9. DO NOT operate any appliance with a damaged cord
or plug, after the appliance malfunctions, or if it has
been dropped or damaged in any manner. Return
appliance to manufacturer for examination, electrical
or mechanical adjustment, or repair.
10. Use appliance only for intended household use as
described in this manual. Any other use not
recommended by the manufacturer may cause fire,
electric shock, or injury to persons. The use of
attachments not recommended or sold by the
manufacturer may cause hazards.
11. DO NOT use outdoors.
12. Always place humidifier on a firm, flat, level surface.
A waterproof mat or pad is recommended for use
under the humidifier. NEVER place it on a rug or
carpet, or on a finished floor that may be damaged
by exposure to water or moisture.
13. DO NOT allow the Moisture Outlet to directly face the
wall. Moisture could cause damage, particularly to
wall paper.
14. Humidifier should be unplugged when not in use.
15. NEVER tilt, move, or attempt to empty unit while it is
operating. Shut off and unplug before removing the
water tank and moving the unit.
16. This humidifier requires daily and weekly
maintenance to operate appropriately. Refer to daily
and weekly cleaning procedures. Use only cleaners
and additives recommended by the manufacturer.
17. NEVER use detergents, gasoline, glass cleaner,
furniture polish, paint thinner, or other household
solvents to clean any part of the humidifier.
18. Excessive humidity in a room can cause water
condensation on windows and some furniture. If this
happens, turn the humidifier OFF.
19. Do not use humidifier in an area where humidity
level is in excess of 50%. Use a hygrometer,
available at your local retailer or through the
manufacturer, to measure the humidity.
20. DO NOT attempt to repair or adjust any electrical or
mechanical functions on this unit. Doing so will void
your warranty. The inside of the unit contains no
user serviceable parts. All servicing should be
performed by qualified personnel only.
21. Never place housing under water flow or immerse in
liquids.
22. Do not plug in the cord with wet hands: electric shock
could result.
FEATURES - OPERATIONS CLEANING/MAINTENANCE
THIS APPLIANCE HAS A POLARIZED PLUG (one blade is wider than the
other). To reduce the risk of electric shock, this plug is intended to fit in a
polarized outlet only one way. If the plug does not fit fully in the outlet,
reverse the plug. If it still does not fit, contact a qualified electrician to
install the proper outlet.
DO NOT ATTEMPT TO MODIFY THIS PLUG OR DEFEAT THIS
SAFETY FEATURE IN ANY WAY.
Figure 1
A. WATER TANK
B. CARRY HANDLE
C. FILTERCHECK®INDICATOR
D. HUMIDIFIER HOUSING
E. CONTROL PANEL
F. HUMIDIFIER BASE
DB
A
EF
C
Figure 2
HM1895-UC_08EM2.qxd:9100030005294 5/28/08 10:38 AM Page 2

Other manuals for HM1895

2

Other Holmes Humidifier manuals

Holmes HM1200 User manual

Holmes

Holmes HM1200 User manual

Holmes HM5601 User manual

Holmes

Holmes HM5601 User manual

Holmes HM1761 User manual

Holmes

Holmes HM1761 User manual

Holmes HM630 User manual

Holmes

Holmes HM630 User manual

Holmes HUL2723B User manual

Holmes

Holmes HUL2723B User manual

Holmes HM2408 User manual

Holmes

Holmes HM2408 User manual

Holmes HM630 User manual

Holmes

Holmes HM630 User manual

Holmes HM7306 User manual

Holmes

Holmes HM7306 User manual

Holmes HM2409 User manual

Holmes

Holmes HM2409 User manual

Holmes COOL MIST HM1700 User manual

Holmes

Holmes COOL MIST HM1700 User manual

Holmes HM3608 User manual

Holmes

Holmes HM3608 User manual

Holmes HWM6000 User manual

Holmes

Holmes HWM6000 User manual

Holmes HM495 User manual

Holmes

Holmes HM495 User manual

Holmes HM1855 User manual

Holmes

Holmes HM1855 User manual

Holmes HM1895 User manual

Holmes

Holmes HM1895 User manual

Holmes HM1865 User manual

Holmes

Holmes HM1865 User manual

Holmes HM2409 User manual

Holmes

Holmes HM2409 User manual

Holmes HM1895 User manual

Holmes

Holmes HM1895 User manual

Holmes HM1230 User manual

Holmes

Holmes HM1230 User manual

Holmes HWF100 User manual

Holmes

Holmes HWF100 User manual

Holmes HM3607 User manual

Holmes

Holmes HM3607 User manual

Holmes HCM1100 User manual

Holmes

Holmes HCM1100 User manual

Holmes HM1700 User manual

Holmes

Holmes HM1700 User manual

Holmes HM7204 User manual

Holmes

Holmes HM7204 User manual

Popular Humidifier manuals by other brands

Philips HU5930 user manual

Philips

Philips HU5930 user manual

Skuttle Indoor Air Quality Products 45 owner's manual

Skuttle Indoor Air Quality Products

Skuttle Indoor Air Quality Products 45 owner's manual

ALDI Stirling HTJ-2108-W user manual

ALDI

ALDI Stirling HTJ-2108-W user manual

American Red Cross Y7087 Cool Mist Humidifier user guide

American Red Cross

American Red Cross Y7087 Cool Mist Humidifier user guide

Essick ED11 800 Care and use manual

Essick

Essick ED11 800 Care and use manual

SOLIS ultrasonic TOWER user manual

SOLIS

SOLIS ultrasonic TOWER user manual

TOTALINE HUMCRSTM3134 Installation & maintenance instructions

TOTALINE

TOTALINE HUMCRSTM3134 Installation & maintenance instructions

Medisana AH 670 instruction manual

Medisana

Medisana AH 670 instruction manual

madebyzen Amaya user guide

madebyzen

madebyzen Amaya user guide

Neptronic SKS4 Series Startup Procedure

Neptronic

Neptronic SKS4 Series Startup Procedure

Hunter Care Free Permawick 34407 instructions

Hunter

Hunter Care Free Permawick 34407 instructions

Venta LPH60 WIFI user manual

Venta

Venta LPH60 WIFI user manual

CA.MI 28118 Humi-Round instruction manual

CA.MI

CA.MI 28118 Humi-Round instruction manual

Aprilaire 56 operating instructions

Aprilaire

Aprilaire 56 operating instructions

Carel humiSteam x-plus user manual

Carel

Carel humiSteam x-plus user manual

Essick Bemis H12 001 Care & use manual

Essick

Essick Bemis H12 001 Care & use manual

KYARA BUNNY instruction manual

KYARA

KYARA BUNNY instruction manual

EUROM 374940 instruction manual

EUROM

EUROM 374940 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.