HomeLink GLOBE7 Manual

Installation and
maintenance manual
for automations for
sectional overhead doors
and spring balanced
up-and-over doors.
(Translation of the original instructions)
GLOBE
IP1839EN- rev. 2011-04-08
DITEC S.p.A.
Via Mons. Banfi, 3 - 21042 Caronno Pertusella (VA) - ITALY
Tel. +39 02 963911 - Fax +39 02 9650314
EN

2
,3(1
INDEX
Subject Page
1. General safety precautions 3
2. Declaration of incorporation of partly completed machinery 4
2.1 Machinery Directive 4
3. Technical data 5
3.1 Operating instructions 6
3.2 Dimensions 6
4. Standard installation 7
5. Main components 8
6. Assembling belt and chain 9
7. Assembling the automation 10
8. Tensioning belt and chain 11
9. Mechanical installation 12
10. Fastening the arm 13
11. Installation of the end stops 14
12. Installation of the manual release 15
13. Installation of the GLOBEC adapter for up-and-over doors 16
14. Installation of the GLOBESI intermediate support 17
15. Electrical connections 18
16. Commands 19
17. Outputs and accessories 20
18. Settings 21
19. Radio receiver operation 23
20. Start up 24
21. Troubleshooting 25
22. Routine maintenance plan 25
23. Operating instructions 26
23.1 General safety precautions 26
23.2 Manual release instructions 27
CAPTION
i
STOP
This symbol indicates instructions or notes regarding safety issues which require particular attention.
This symbol indicates informations which are useful for correct product function.
This symbol indicates options and parameters which are only available with the indicated item.
This symbol indicates options and parameters which are not available with the indicated item.
This symbol indicates instructions or notes intended for technical and expert personnel.
This symbol indicates operations not to be effected for not compromise the correct operation of the
automation.
All right reserved
$OOGDWDDQGVSHFL¿FDWLRQVKDYHEHHQGUDZQXSDQGFKHFNHGZLWKWKHJUHDWHVWFDUH7KHPDQXIDFWXUHUFDQQRW
KRZHYHUWDNHDQ\UHVSRQVLELOLW\IRUHYHQWXDOHUURUVRPPLVLRQVRULQFRPSOHWHGDWDGXHWRWHFKQLFDORULOOXVWUDWLYH
purposes.

3,3(1
1. GENERAL SAFETY PRECAUTIONS
This installation manual is intended for professionally competent personnel only.
,QVWDOODWLRQHOHFWULFDOFRQQHFWLRQVDQGDGMXVWPHQWVPXVWEHSHUIRUPHGLQDFFRUGDQFHZLWK*RRG:RUNLQJ
Methods and in compliance with applicable regulations.
%HIRUHLQVWDOOLQJWKHSURGXFWFDUHIXOO\UHDGWKHLQVWUXFWLRQV%DGLQVWDOODWLRQFRXOGEHKD]DUGRXV7KHSDFNDJLQJ
materials (plastic, polystyrene, etc.) should not be discarded in the environment or left within reach of children,
as these are a potential source of hazard.
%HIRUHLQVWDOOLQJWKHSURGXFWPDNHVXUHLWLVLQSHUIHFWFRQGLWLRQ
'RQRWLQVWDOOWKHSURGXFWLQDQH[SORVLYHHQYLURQPHQWDQGDWPRVSKHUHJDVRULQÀDPPDEOHIXPHVDUHDVHULRXV
KD]DUGULVN
%HIRUHLQVWDOOLQJWKHPRWRUVPDNHDOOVWUXFWXUDOFKDQJHVUHODWLQJWRVDIHW\FOHDUDQFHVDQGSURWHFWLRQRUVHJUH-
JDWLRQRIDOODUHDVZKHUHWKHUHLVULVNRIEHLQJFUXVKHGFXWRUGUDJJHGDQGGDQJHUDUHDVLQJHQHUDO
0DNHVXUHWKHH[LVWLQJVWUXFWXUHLVXSWRVWDQGDUGLQWHUPVRIVWUHQJWKDQGVWDELOLW\7KHPRWRUPDQXIDFWXUHU
LVQRWUHVSRQVLEOHIRUIDLOXUHWRXVH*RRG:RUNLQJ0HWKRGVLQEXLOGLQJWKHIUDPHVWREHPRWRUL]HGRUIRUDQ\
deformation occurring during use.
7KHVDIHW\GHYLFHVSKRWRFHOOVVDIHW\HGJHVHPHUJHQF\VWRSVHWFPXVWEHLQVWDOOHGWDNLQJLQWRDFFRXQW
DSSOLFDEOHODZVDQGGLUHFWLYHV*RRG:RUNLQJ0HWKRGVLQVWDOODWLRQSUHPLVHVV\VWHPRSHUDWLQJORJLFDQGWKH
forces developed by the motorized barrier.
7KHVDIHW\GHYLFHVPXVWSURWHFWDQ\DUHDVZKHUHWKHULVNH[LVWVRIEHLQJFUXVKHGFXWRUJUDJJHGRUZKHUH
WKHUHDUHDQ\RWKHUULVNVJHQHUDWHGE\WKHPRWRUL]HGEDUULHU
Apply hazard area notices required by applicable regulations.
(DFKLQVWDOODWLRQPXVWFOHDUO\VKRZWKHLGHQWL¿FDWLRQGHWDLOVRIWKHPRWRUL]HGEDUULHU
%HIRUHPDNLQJSRZHUFRQQHFWLRQVPDNHVXUHWKHSODWHGHWDLOVFRUUHVSRQGWRWKRVHRIWKHSRZHUPDLQV
Fit an omnipolar disconnection switch with a contact opening gap of at least 3 mm.
0DNHVXUHDQDGHTXDWHUHVLGXDOFXUUHQWFLUFXLWEUHDNHUDQGRYHUFXUUHQWFXWRXWDUH¿WWHGXSVWUHDPRIWKHHOHF-
trical system. When necessary, connect the motorized barrier to a reliable earth system made in accordance
with applicable safety regulations.
During installation, maintenance and repair, interrupt the power supply before opening the lid to access the
electrical parts.
To handle electronic parts, wear earthed antistatic conductive bracelets. The motor manufacturer decli-
QHVDOOUHVSRQVLELOLW\LQWKHHYHQWRIFRPSRQHQWSDUWVEHLQJ¿WWHGWKDWDUHQRWFRPSDWLEOHZLWKWKHVDIH
an correct operation.
For repairs or replacements of products only original spare parts must be used. The installer shall provide all
information relating to automatic, manual and emergency operation of the motorized barrier, and provide the
user with operating instructions.

4
,3(1
2. DECLARATION OF INCORPORATION OF PARTLY COMPLETED MACHINERY
(Directive 2006/42/EC, Annex II-B)
7KHPDQXIDFWXUHU',7(&6S$ZLWKKHDGTXDUWHUVLQ9LD0RQV%DQ¿&DURQQR3HUWXVHOOD9$
ITALY declares that the automation for sectional doors type GLOBE:
- has been constructed to be installed on a manual gate to construct a machine pursuant to the Directive
2006/42/EC. The manufacturer of the motorized gate shall declare conformity pursuant to the Directive
2006/42/EC (annex II-A), prior to the machine being put into service;
- conforms to applicable essential safety requirements indicated in annex I, chapter 1 of the Directive
2006/42/EC;
- conforms to the Low Voltage Directive 2006/95/EC;
- conforms to the Electromagnetic Compatibility Directive 2004/108/EC;
- technical documentation conforms to annex VII-B to the Directive 2006/42/EC;
WKHWHFKQLFDO¿OHLVPDQDJHGE\5HQDWR&DO]DZLWKRI¿FHVLQ9LD0RQV%DQ¿&DURQQR3HUWX-
sella (VA) - ITALY;
- a copy of technical documentation will be provided to national competent authorities, following a suitably
MXVWL¿HGUHTXHVW
Caronno Pertusella, 13-12-2010 Silvano Angaroni
(Managing Director)
2.1 Machinery Directive
Pursuant to Machinery Directive (2006/42/CE) the installer who motorises a door or gate has the same obliga-
tions as the manufacturer of machinery and as such must:
SUHSDUHWKHWHFKQLFDO¿OHZKLFKPXVWFRQWDLQWKHGRFXPHQWVLQGLFDWHGLQ$QQH[9RIWKH0DFKLQHU\'LUHFWLYH
7KHWHFKQLFDO¿OHPXVWEHNHSWDQGSODFHGDWWKHGLVSRVDORIFRPSHWHQWQDWLRQDODXWKRULWLHVIRUDWOHDVW
ten years from the date of manufacture of the motorized gate);
- draft the EC declaration of conformity in accordance withAnnex II-Aof the Machinery Directive and deliver
it to the customer;
DI¿[WKH&(PDUNLQJRQWKHSRZHURSHUDWHGJDWHLQDFFRUGDQFHZLWKSRLQWRI$QQH[,RIWKH0DFKLQHU\
Directive.

5,3(1
3. TECHNICAL DATA
GLOBE7 GLOBE10
Power supply 230 V~ / 50-60 Hz 230 V~ / 50-60 Hz
Absorption 0,7 A 1,2 A
Thrust 500 N 900 N
Opening speed 0,18 m/s 0,15 m/s [chain]
0,18 m/s [belt]
Closing speed 0,12 m/s 0,10 m/s [chain]
0,12 m/s [belt]
Maximum load 7 m210 m2
Carriage maximum stroke 2760 mm
3820 mm [GLOBELV1] 2760 mm
3820 mm [GLOBEL1-GLOBELV1]
Service class 3 - FREQUENT 3 - FREQUENT
Intermittence S2 = 30 min
S3 = 50% S2 = 30 min
S3 = 50%
Temperature -20° C / +55° C -20° C / +55° C
Degree of protection IP10 IP10
GLOBE7J GLOBE10J
Power supply 120 V~ / 50-60 Hz 120 V~ / 50-60 Hz
Absorption 1,4 A 2,4 A
Thrust 500 N 900 N
Opening speed 0,18 m/s 0,15 m/s [chain]
0,18 m/s [belt]
Closing speed 0,12 m/s 0,10 m/s [chain]
0,12 m/s [belt]
Maximum load 7 m210 m2
Carriage maximum stroke 2760 mm
3820 mm [GLOBELV1] 2760 mm
3820 mm [GLOBEL1-GLOBELV1]
Service class 3 - FREQUENT 3 - FREQUENT
Intermittence S2 = 30 min
S3 = 50% S2 = 30 min
S3 = 50%
Temperature -20° C / +55° C -20° C / +55° C
Degree of protection IP10 IP10
Control panel 70R 71R
F1 fuse F1,6A F1,6A
Motor power supply 24 V= / 8 A 24 V= / 12 A
Accessories power supply 24 V= / 0,3 A 24 V= / 0,3 A
Control panel 70R 71R
F1 fuse F3,15A F3,15A
Motor power supply 24 V= / 8 A 24 V= / 12 A
Accessories power supply 24 V= / 0,3 A 24 V= / 0,3 A

6
,3(1
3.2 Dimensions
127(XQOHVVRWKHUZLVHVSHFL¿HGDOOPHDVXUHPHQWVDUHH[SUHVVHGLQPLOOLPHWUHVPP
i
208
124
490
3.1 Operating instructions
Service class: 3 PLQLPXP·\HDUVRIZRUNLQJOLIHZLWK·F\FOHVSHUGD\
Applications: FREQUENT (for multi-family entrances or small condominiums with frequent vehicle or pede-
strian access).
- Performance characteristics are to be understood as referring to the recommended weight (approx. 2/3 of
maximum permissible weight). When used with the maximum permissible weight a reduction in the above
mentioned performance can be expected.
6HUYLFHFODVVUXQQLQJWLPHVDQGWKHQXPEHURIFRQVHFXWLYHF\FOHVDUHWREHWDNHQDVPHUHO\LQGLFDWLYH
Havingbeenstatistically determinedunderaverageoperating conditions, and are thereforenot necessarily
DSSOLFDEOHWRVSHFL¿FFRQGLWLRQVRIXVH
- Each automatic entrance has variable elements such as: friction, balancing and environmental factors,
all of which may substantially alter the performance characteristics of the automatic entrance or curtail
LWVZRUNLQJOLIHRUSDUWVWKHUHRILQFOXGLQJWKHDXWRPDWLFGHYLFHVWKHPVHOYHV7KHLQVWDOOHUVKRXOGDGRSW
suitable safety conditions for each particular installation.

7,3(1
4. STANDARD INSTALLATION
Ref. Code Description
1 GLOBE7
GLOBE10 Motor + control panel
2 GLOBEL1
GLOBELV1
GLOBESI
Extension set for chain automation
Extension set for belt automation
Intermediate guide support
3 LAMPH Flashing light
4 ASB1
ASB2
GLOBESB
.LWIRUWKHH[WHUQDOUHOHDVHFRUGZLWKORFN
&RUGEORFNLQJGHYLFHPP
&RUGEORFNLQJGHYLFHPP
5 GOL4 Radio
6 XEL2
LAB4
LAB4S
Photocells
7 Safety edge
8BATK1 %XIIHUEDWWHU\NLW
A Connect the power supply to an approved omnipolar switch with an opening distance
of the contacts of at least 3mm (not supplied).
The connection to the mains must be made via an independent channel, separated
from the connections to command and safety devices.
i
127(WKHJLYHQRSHUDWLQJDQGSHUIRUPDQFHIHDWXUHVFDQRQO\EHJXDUDQWHHGZLWKWKHXVHRI',7(&
DFFHVVRULHVDQGVDIHW\GHYLFHV
A
5
7
2x1.5 mm²
RG58 + 2x1.5 mm²
4x0.5 mm²
4x0.5 mm²
6
1
2
4
3
8
6

8
,3(1
5. MAIN COMPONENTS
Ref. Code Description
1 24 V= motor with encoder
2)DVWHQLQJEUDFNHW
3 Slide carriage
4 Sliding guide
5 Fastening arm
6'RRUVHFWLRQUHWHQWLRQEUDFNHW
7 Control panel
2
1
4
3
5
6
7
30
2010
500

9,3(1
6. ASSEMBLING BELT AND CHAIN
- Attach the belt or chain [A] to the transmission [B] and slide [C].
- Assemble the belt stop [D].
- Fasten the two ends of the belt [A] to the release pin [E] through the couplings [F] in the direction of the
SLQDVVKRZQLQWKH¿JXUH
- Fasten the two ends of the chain [A] to the release pin [E] through the couplings [F] in the direction of the
SLQDVVKRZQLQWKH¿JXUH
1
C
B
2
D
A
A
F
E
AE
3B
3A
F
FE
EF

10
,3(1
7. ASSEMBLING THE AUTOMATION
- Insert the guide [B] into the non-bevelled side of the coupling [C] until it reaches the stop.
- Insert the guide [D] into the bevelled side of the coupling [C] until it reaches the stop.
- Insert the guide [D] into the non-bevelled side of the coupling [E] until it reaches the stop.
-Lay out the belt or chain [A] and insert it into the carriage side of assembled guide [B]+[C]+[D]+[E].
0RXQWWKHJXLGH>%@RQWKHGULYHXQLWDQGSDVVWKHEHOWRUFKDLQ>$@RYHUWKHSXOOH\>+@EORFNLQJLWZLWKWKH
pin [I]. Attach the guide [B] to the drive unit using the screw [J].
- Place the guide [F] over the coupling [E].
- Insert the transmission [G] correctly into the guide [F], raising the guide to facilitate insertion.
- Insert the guide [F] into the coupling [E].
- the coupling [E] towards the transmission [G] until its reaches the guide stop [F].
EF
D
B B
C C
C
D
1 2 3
A
370
1066 1066
205 400 370205 400 370
1066
205
B D F G
C E
A
H
I
B
J
127(WKHFRUUHFWGLUHFWLRQIRULQVHUWLQJWKHJXLGHLQVKRZQLQWKH¿JXUH
i

11 ,3(1
8. TENSIONING BELT AND CHAIN
$VVHPEOHWKHWUDQVPLVVLRQXQLWDVLQGLFDWHGLQWKH¿JXUH
- To tension the chain or belt correctly, 1÷2 mm should be left between the spring retainer [A] and the stop
[B], so that the spring [C] can function properly.
:$51,1*RYHUWHQVLRQLQJWKHFKDLQRUEHOWZLOOSUHYHQWWKHDXWRPDWLFV\VWHPIURPIXQFWLRQLQJSURSHUO\
1 2
A
B
C A
C
1÷2
B

12
,3(1
9. MECHANICAL INSTALLATION
6HOHFWDQGPDUNWKHSRLQWZKHUHWKHJXLGHZLOOEHPRXQWHGRQWKHZDOODQGFHLOLQJ
/HDYLQJWKHFRQWUROXQLWRQWKHÀRRUPRXQWWKHJXLGH>$@RQWKHZDOOXVLQJWKHWUDQVPLVVLRQVXSSRUWEUDFNHW
[B].
,QVHUWWKHUHWHQWLRQEUDFNHWV>&@DQGORFNWKHPLQSODFHZLWKWKHVFUHZVSURYLGHG
5DLVHWKHFRQWUROXQLWDQGEHQGWKHEUDFNHWVDVQHFHVVDU\H[FHVVSDUWVFDQEHUHPRYHGWKHQDWWDFKWR
the ceiling.
A
B
C
10÷100
45°
min 680

13 ,3(1
10. FASTENING THE ARM
0RXQWWKHGRRUVHFWLRQUHWHQWLRQEUDFNHW>$@RQWKHWRSRIWKHGRRUXVLQJWKHUHLQIRUFHPHQWDQJOHEUDFNHWV
[B] provided, if necessary.
- Release the automation as shown on page 27. Bring the slide [C] to the closed door and attach the arm [D]
to the slide [C] so as to form approximately a 45° angle with the upright section of the door. If necessary
adjust the length of the arm [D] using the extension [E].
:$51,1*LQRUGHUWRRSHQSDUWLFXODUO\KLJKVHFWLRQDOGRRUVFRPSOHWHO\WKHDWWDFKPHQWSRLQW>)@FDQEH
PRYHGPPWRPPLQZDUGVIURPWKHSRLQWZKHUHWKHGRRUVHFWLRQUHWHQWLRQEUDFNHW>$@LVIDVWHQHG
LQVHUWLQJDVKLP>*@LIQHFHVVDU\QRWSURYLGHGPD[PPVRDVWRLQFUHDVHWKHVOLGHVWURNHDQGXVH
DOORIWKHDYDLODEOHJXLGH
$QDQJOHRIDSSUR[LPDWHO\VKRXOGDOZD\VEHNHSWEHWZHHQWKHDUPDQGXSULJKWVHFWLRQRIWKHVHFWLRQDOGRRU
A
BB
A
C
A
D
F
45°
C
45°
D
E
F
G
max
200
20÷100
A

14
,3(1
11. INSTALLATION OF THE END STOPS
,QVHUWWKHRSHQLQJHQGVWRS>$@LQWKHJXLGH>%@DVVKRZQLQWKH¿JXUHDQGIDVWHQLWLQSODFHZKHUHSUH-
ferred.
,QVHUWWKHFORVLQJHQGVWRS>&@LQWKHJXLGH>%@DVVKRZQLQWKH¿JXUHDQGIDVWHQLWLQSODFHZKHUHSUH-
ferred.
AC B
L
L = max 2760
max 3820 [GLOBEL1-GLOBELV1]

15 ,3(1
DOORTYPE
YEAROFMANUF
A
CTURE
V
OL
T
A
GESUPPL
Y
SERIAL
NUMBER
2
1
12. INSTALLATION OF THE MANUAL RELEASE
In order to facilitate the release and movement of the sectional door, position the cord release near the handle,
DVVKRZQLQWKH¿JXUH

16
,3(1
13. INSTALLATION OF THE GLOBEC ADAPTER FOR UP-AND-OVER DOORS
max 210
min 20
min 900

17 ,3(1
14. INSTALLATION OF THE GLOBESI INTERMEDIATE SUPPORT
1
220
50
30 75
2
12

18
,3(1
15. ELECTRICAL CONNECTIONS
7KH¿JXUHVKRZVWKHPDLQFRQQHFWLRQVRIWKHFRQWUROSDQHO55
-
+
Output 24 V= / max 0.3 A
Stop
Safety re-opening
Step-by-step
Lamp
Electric lock
Flashing light
TCR1
SIG
ON
OFF 123 4 5 6
PRG
SA
POWER
ALARM
1515 13 14 0 89
ENC
BATK1
Transformer
24V=
Motor
GOL4
COM
BIXMR2
M+
M-
24 V~
AUX
ANT
F1
Power supply
SO
JR4
JR3
JR2
Courtesy
light
5
6
Black
Blue
GLOBE10
1
5
1
3
GLOBE10

19 ,3(1
16. COMMANDS
Command Function Description
1 5 N.O. STEP-BY-STEP With DIP1=OFF, the closing of the contact activates opening
or closing operations in the following sequence: open-stop-
close-open.
NOTELIDXWRPDWLFFORVLQJLVHQDEOHGWKHVWRSLVQRWSHUPDQHQW
EXWODVWVIRUDGXUDWLRQVHWE\7&
OPENING WITH
AUTOMATIC
CLOSING
With DIP1=ON and TC<MAX, the closing of the contact acti-
vates the opening operation.
OPENING WITHOUT
AUTOMATIC
CLOSING
With DIP1=ON and TC=MAX, the closing of the contact acti-
vates the opening operation.
NOTERQFHWKHDXWRPDWLRQVWRSVWKHFORVLQJRIWKHFRQWDFW
SHUIRUPVWKHRSSRVLWHRSHUDWLRQWRWKHRQHSHUIRUPHGEHIRUH
VWRS
1 8 N.C. REVERSE
SAFETY CONTACT The opening of the safety contact triggers a reversal of motion
(re-opening) during closing.
1 9 N.C. STOP The opening of the safety contact stops the current operation.
PRG
N.O. TRANSMITTERS
STORAGE AND
CANCELLATION
:$51,1*WKH%,;05VWRUDJHPRGXOHPXVWEHLQVHUWHG
Transmitter storage:
SUHVVWKH35*NH\WKH6,*/('FRPHVRQ
WUDQVPLWWKHWUDQVPLWWHUWREHVWRUHGWKH6,*/('ÀDVKHV
- wait 10 s to complete storage (the SIG LED goes out).
Transmitter cancellation:
SUHVVWKH35*NH\IRUVHFWKH6,*/('ÀDVKHV
SUHVVWKH35*NH\IRUDQRWKHUVHFWKH6,*/('ÀDVKHV
TXLFNO\
:$51,1*PDNHDMXPSHUIRUDOOWKH1&FRQWDFWVLIQRWLQXVH7KHWHUPLQDOVZLWKWKHVDPHQXPEHU
DUHHTXDO

20
,3(1
17. OUTPUTS AND ACCESSORIES
Output Value - Accessories Description
01
+
-
24 V= / 0.3 A Accessories power supply. Power supply output for external ac-
cessories, including automation status lamp.
0 14 LAMPH
24 V= / 25 W Flashing light. Activated during opening and closing operations.
24 V= / 25 W Internal courtesy light. A courtesy light that turns on for 180 se-
conds with every opening (total or partial), step-by-step and closing
command can be connected.
1 13 24 V= / 3 W
Automation status lamp (proportional).
The light switches off when the automation is closed; the light
VZLWFKHVRQZKHQWKHDXWRPDWLRQLVRSHQWKHOLJKWÀDVKHVZLWKD
variable frequency while the automation is operating.
0 15 24 V= / 1.2 A max Electric lock. With DIP5=ON, on with the door closed.
0 15 12 V / 15 W Electric lock.:LWKD9HOHFWULFORFNFRQQHFWWKHVXSSOLHG
5 W resistance in series.
With DIP5=ON, on with the door closed.
ANT
BIXAL Connect the supplied antenna wire (173 mm), or alternatively the
BIXAL antenna, using a coaxial cable, type RG58.
AUX
The control panel has one housing for plug-in cards such as a radio
receiver type, magnetic loops, etc.
Plug-in card operating is selected using DIP1.
:$51,1*WKHSOXJLQFDUGVPXVWEHLQVHUWHGDQGUHPRYHGZLWK
WKHSRZHUVXSSO\GLVFRQQHFWHG
COM BIXMR2
The BIXMR2 storage module allows remote controls to be stored.
If the control panel is replaced, the BIXMR2 storage module being
used can be inserted in the new control panel.
:$51,1*WKHVWRUDJHPRGXOHPXVWEHLQVHUWHGDQGUHPRYHGZLWK
WKHSRZHUVXSSO\GLVFRQQHFWHG
BAT BATK1
2 x 12 V / 2 Ah
Battery operating. 7KHEDWWHULHVDUHNHSWFKDUJHGZKHQWKHSRZHU
supply is on. If the power supply is off, the control panel is powered
by the batteries until power is re-established or until the battery
voltage drops below the safety threshold. If this occurs, the control
panel turns off.
:$51,1*WKHEDWWHULHVPXVWDOZD\VEHFRQQHFWHGWRWKHFRQWURO
SDQHOIRUFKDUJLQJ3HULRGLFDOO\FKHFNWKHHI¿FLHQF\RIWKHEDWWHULHV
127(WKHRSHUDWLQJWHPSHUDWXUHRIWKHUHFKDUJHDEOHEDWWHULHVLV
DSSUR[LPDWHO\&&
GLOBE10
Other manuals for GLOBE7
1
This manual suits for next models
1
Table of contents
Other HomeLink Garage Door Opener manuals
Popular Garage Door Opener manuals by other brands

Chamberlain
Chamberlain Whisper Drive WD912K owner's manual

Guardian
Guardian 315 owner's manual

Chamberlain
Chamberlain Security+ 1215EM FS2 owner's manual

Multi-code
Multi-code 1090 installation instructions

RollSeal
RollSeal RS-500 Series installation manual

Etdoor
Etdoor 600E Installation instructions and user guide