#ISU
ISU
Name
ISU
Options
(defaults
in
bold)
Notes
356
Aux
Heat
Lock
Out
(Aux
Heat
Outdoor
Lockout)
Off,
5
°F
to
65
°F
(in
5
°F
increments)
or
-15.0
°C
to
18.5
°C
(in
2.5
°C
or
3.0
°C
increments)
Aux
Heat
Lockout
requires
an
outdoor
temperature.
Set
Aux
Heat
Lockout
to
optimize
energy
bills
and
to
not
allow
it
to
run
the
more
expensive
Aux
Heat
source
above
certain
outdoor
temperature
limit.
This
ISU
is
only
displayed
if
ISU
200
is
set
to
Heat
Pump,
AND
ISU
260
is
set
to
Thermostat
control
AND
if
ISU
221
Aux/E
stages
="1.
365
Cooll
CPH
(Cooling
cycle
rate
stage
1)
1-6CPH(3CPH)
This
ISU
is
only
displayed
when
Cool
/Compressor
Stages
is
set
to
1
or
more
stages.
Cycle
rate
limits
the
maxi
mum
number
of
times
the
system
can
cycle
in
a
1
hour
period
measured
at
a
50%
load.
For
example,
when
set
to
3
CPH,
at
a
50%
load,
the
most
the
system
will
cycle
is
3
times
per
hour
(10
minutes
on,
10
minutes
off).
The
system
cycles
less
often
when
load
conditions
are
less
than
or
greater
than
a
50%
load.
366
Cool
2
CPH
(Cooling
cycle
rate
stage
2)
1-6CPH(3CPH)
This
ISU
is
only
displayed
when
Cool
/Compressor
Stages
is
set
to
2.
370
Heat
1
CPH
(Heating
cycle
rate
stage
1)
1-12CPH
This
ISU
is
only
displayed
when
Heat
Stages
is
set
to
1
stage
or
more
stages.
Cycle
rate
limits
the
maximum
number
of
times
the
system
can
cycle
in
a
1
hour
period
measured
at
a
50%
load.
For
example,
when
set
to
3
CPH,
at
a
50%
load,
the
most
the
system
will
cycle
is
3
times
per
hour
(10
minutes
on,
10
minutes
off).
The
system
cycles
less
often
when
load
conditions
are
less
than
or
greater
than
a
50%
load.
The
recommended
(default)
cycle
rate
settings
are
below
for
each
heating
equipment
type:
Standard
Efficiency
Gas
Forced
Air
-
5
CPH;
High
Efficiency
Gas
Forced
Air
=
3
CPH;
Oil
Forced
Air
=
5
CPH;
Electric
Forced
Air
=
9
CPH;
Fan
Coil
•»
3
CPH;
Hot
Water
Radiant
Heat
=
3
CPH;
Steam
•»
1
CPH.
371
Heat
2
CPH
(Heating
cycle
rate
stage
2)
1-12CPH
This
ISU
is
only
displayed
when
Heat
Stages
is
set
to
2
stages.
The
recommended
(default)
cycle
rate
settings
are
below
for
each
heating
equipment
type:
Standard
Efficiency
Gas
Forced
Air
»
5
CPH;
High
Efficiency
Gas
Forced
Air
=
3
CPH;
Oil
Forced
Air
-
5
CPH;
Electric
Forced
Air
=
9
CPH;
Fan
Coil
=
3
CPH;
Hot
Water
Radiant
Heat
=
3
CPH;
Steam
=
1
CPH.
375
Aux
Heat
CPH
(Heating
cycle
rate
Auxiliary
Heat)
1-12CPH
This
ISU
is
only
displayed
when
ISU
200
=
Heat
Pump
and
ISU
221-1.
It
is
only
displayed
when
Auxiliary
Heat
is
configured.
The
recommended
cycle
rate
settings
are
below
for
each
heating
equipment
type:
Standard
Efficiency
Gas
Forced
Air
»
5
CPH;
High
Efficiency
Gas
Forced
Air
°
3
CPH;
Oil
Forced
Air
=
5
CPH;
Electric
Forced
Air
=
9
CPH.
378
EM
Heat
CPH
(Heating
cycle
rate
Emergency
Heat)
1-12CPH
This
ISU
is
only
displayed
when
Emergency
Heat
is
configured
and
ISU
253:
Aux/E
Terminal
Control
is
set
to
control
Aux
and
E
heat
Independently.
The
recommended
cycle
rate
settings
are
below
for
each
heating
equip
ment
type:
Standard
Efficiency
Gas
Forced
Air
°
5
CPH;
High
Efficiency
Gas
Forced
Air
=
3
CPH;
Oil
Forced
Air
=
5
CPH;
Electric
Forced
Air
=
9
CPH.
387
Compressor
Protection
Off,
1-5
minutes
The
thermostat
has
a
built
in
compressor
protection
(minimum
off
timer)
that
prevents
the
compressor
from
restarting
too
early
after
a
shutdown.
The
minimum-off
timer
is
activated
after
the
compressor
turns
off.
If
there
is
a
call
during
the
minimum-off
timer,
the
thermostat
shows
"Wait"
in
the
display.
This
ISU
is
displayed
if
ISU
220
is
set
to
at
least
1
stage.
390
ExtFan
RunTime
in
Cool
Off,
30.60,90
seconds
2,3,4,5,6,7,8,9,10,11,12,13,14,15
minutes
After
the
call
for
cooling
ends,
the
thermostat
keeps
the
fan
on
for
the
selected
amount
of
time
for
increased
efficiency.
This
may
reintroduce
humidity
into
the
living
space.
This
ISU
is
displayed
if
ISU
220
Is
set
to
at
least
1
stage.