Honeywell UltraKey Lite HJC5000 User manual

Document 800-07422 – Rev A – 08/10
Installation and User Guide
UltraKey Lite
Keyboard controller for VideoBloX
and MAXPRO-Net Matrix Systems
HJC5000


Installation and User
Guide

Revisions
Issue Date Revisions
800-03854 rev A 02/2009 New document.
800-03854 rev B 03/2009 Updated the MaxPRO map code.
800-03854 rev C 04/2009 Corrected the controller login PIN code; corrected IP address p. 59;
updated images for quality
800-07422 rev A 08/2010 Revisions to Step 3: Configure Address, Baud Rate or IP for VideoBloX
Mode; Step 4: Configure VideoBloX Mode Default Settings While Powering
Up; Step 4: Configure the Controller for an Ethernet Connection; added
Step 5: Setting the Keyboard Address While Powering Up; and, the System
Configuration Menu screen.
4

Document 800-07422 Rev A 5
08/10
Explanation of Symbols
FCC Compliance Statement
Information to the User: This equipment has been tested and found to comply with the limits for a Class B digital
device. Pursuant to Part 15 of the FCC Rules, these limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to
radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference. For example, try orienting or
relocating the receiving antenna, increasing the separation between the equipment and receiver, or connecting the
equipment to an outlet on a different circuit.
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device
may not cause harmful interference, and (2) this device must accept any interference received, including interference
that may cause undesired operation.
WARNING! The exclamation point in a red octagon is a WARNING. Failure to take
or avoid a specific action could result in physical harm to a person
or irreparable damage to equipment.
Caution The lightning flash with arrowhead symbol within an equilateral triangle
alerts the user to the presence of uninsulated dangerous voltage within the
enclosure of the product that may be of sufficient magnitude to
constitute a risk of electric shock to the person
Caution The exclamation point in a yellow equilateral triangle is a Caution. Failure
to take or avoid a specified action could result in loss of data or damage
to equipment and may contain important operating and maintenance
servicing information.

6
Canadian Compliance Statement
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
European Compliance Statement
The manufacturer declares that the equipment supplied with this guide is compliant with the essential protection
requirements of the EMC directive 2004/108/EC and the Low Voltage Directive LVD 2006/95/EC, conforming to the
requirements of standards EN 55022 for emissions, EN 50130-4 for immunity, and EN 60065 for Electrical Equipment
safety.
Caution Users of the product are responsible for checking and complying with all federal, state, and local
laws and statutes concerning the monitoring and recording of video and audio signals.
Honeywell shall not be held responsible for the use of this product in violation of current laws and
statutes.
Warnings and Cautions
Read the following cautions and warnings prior to installation and use of this product.
Changes or modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
Users of the product are responsible for checking and complying with all federal, state and
local laws and statutes concerning the monitoring and recording of video and audio signals.
Honeywell Systems Group shall not be held responsible for the use of this product in violation
of current laws and statutes.
Installation and servicing must be performed by qualified personnel in accordance with
local codes and regulations.

Document 800-07422 Rev A 7
08/10
Important Safety Instructions
BEFORE OPERATING OR INSTALLING THE UNIT, READ AND FOLLOW ALL INSTRUCTIONS.
AFTER INSTALLATION, retain the safety and operating instructions for future reference
1. HEED WARNINGS - Adhere to all warnings on the unit and in the operating instructions.
2. INSTALLATION
• Install in accordance with the manufacturer’s instructions.
• Installation and servicing should be performed only by qualified and experienced technicians to conform to
all local codes and to maintain your warranty.
• Do not install the unit in an extremely hot or humid location, or in a place subject to dust or mechanical
vibration. The unit is not designed to be waterproof. Exposure to rain or water may damage the unit.
3. POWER SOURCES - This product should be operated only from the type of power source indicated on the
marking label. If you are not sure of the type of power supplied to your facility, consult your product dealer or
local power company.
4. HEAT - Situate away from items that produce heat or are heat sources such as radiators, heat registers, stoves,
or other products (including amplifiers).
5. WATER AND MOISTURE - Do not use this unit near water or in an unprotected outdoor installation, or any area
classified as a wet location.
6. ATTACHMENTS - Do not use attachments not recommended by the product manufacturer as they may result in
the risk of fire, electric shock, or injury to persons.
7. ACCESSORIES - Only use accessories specified by the manufacturer.
8. CLEANING - Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning.
9. SERVICING - Do not attempt to service this unit yourself as opening or removing covers may expose you to
dangerous voltage or other hazards. Refer all servicing to qualified service personnel.
Consider using a UPS source to ensure satisfactory performance.
Using replacement parts or accessories other than the original manufacturers may invalidate the
warranty.
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK).
NO USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN

8
10. REPLACEMENT PARTS - When replacement parts are required, be sure the service technician has used
replacement parts specified by the manufacturer or have the same characteristics as the original part.
Unauthorized substitutions may result in fire, electric shock or other hazards.
Warranty and Service
Subject to the terms and conditions listed on the Product Warranty Card, during the warranty period Honeywell will
repair or replace, at its sole option, free of charge, any defective products returned prepaid.
In the event you have a problem with any Honeywell product, call Customer Service for assistance or to request a
Return Merchandise Authorization (RMA) number. Be sure to have the model number, serial number, and the nature
of the problem available for the technical service representative.
In the U.S.A. and Canada, call 1.800.796.2288. See the back cover for other contact details.
Prior authorization must be obtained for all returns, exchanges, or credits. Items shipped to Honeywell without a
clearly identified Return Merchandise Authorization (RMA) number may be refused.
WEEE (Waste Electrical and Electronic Equipment). Correct disposal of
this product (applicable in the European Union and other European
countries with separate collection systems). This product should be
disposed of, at the end of its useful life, as per applicable local laws,
regulations, and procedures

UltraKey Lite Controller Installation and User Guide
Document 800-07422 Rev A 9
08/10
Contents
1 About this Document and the UltraKey Lite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Document Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Finding More Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Typographical Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
UltraKey Lite Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Shipping Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
UltraKey Lite Port Connections and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
2 Using the UltraKey Lite Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Logging Onto the Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Using the UltraKey Lite to Navigate the LCD Menus. . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
VideoBloX Key Functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
MAXPRO Key Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
3 Installing UltraKey Lite with VideoBloX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Navigating the LCD Configuration Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Installing and Configuring a Serial Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Installing and Configuring an Ethernet Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
(Optional) Configuring UltraKey Lite Using the Web Browser . . . . . . . . . . . . . . . . . . . . . . . 41
4 Installing UltraKey Lite with MAXPRO-Net . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Navigating the LCD Configuration Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Installing and Configuring a Serial Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Installing and Configuring an Ethernet Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
(Optional) Configuring UltraKey Lite Using the Web Browser . . . . . . . . . . . . . . . . . . . . . . . 60
5 System Administration and Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
System Administration Using the Controller LCD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
System Administration Using the Web Browser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68

10

UltraKey Lite Controller Installation and User Guide
Document 800-07422 Rev A 11
08/10
Figures
Figure 1-1 UltraKey Lite Port Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Figure 1-2 Terminal Box Front and Back Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Figure 2-1 UltraKey Lite Controller Keyboard Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Figure 2-2 The UltraKey Navigation Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Figure 3-1 LCD and LCD Navigation Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Figure 3-2 VideoBloX LCD Configuration Menu Tree . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Figure 3-3 AC Power Adapter with CEE 7/16 Europlug . . . . . . . . . . . . . . . . . . . . . . . . . 33
Figure 3-4 RJ45 to DB9 Male Adapter for VideoBloX and VideoBloX Lite CPUs . . . . . . . . . . . . . 34
Figure 3-5 Direct RJ45 Serial Port Connection for VideoBloX NetCPUs . . . . . . . . . . . . . . . . . 34
Figure 3-6 VideoBloX Serial Port RS422 Connection Example . . . . . . . . . . . . . . . . . . . . . . 34
Figure 3-7 Ethernet Port Connections to VideoBloX . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Figure 3-8 UltraKey Lite Login Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Figure 3-9 System Configuration Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Figure 3-10 VideoBloX Configuration Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Figure 3-11 Serial Port Configuration Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Figure 3-12 IP Configuration Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Figure 3-13 DynKey Configuration Tab. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Figure 4-1 LCD and Navigation Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Figure 4-2 MAXPRO LCD Menu Tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Figure 4-3 RS232 Serial Port Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Figure 4-4 RS232 Serial Port Connection and MegaPIT . . . . . . . . . . . . . . . . . . . . . . . . . 50
Figure 4-5 RS232 Serial Port Connection and MX18 . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Figure 4-6 AC Power Adapter with CEE 7/16 Europlug . . . . . . . . . . . . . . . . . . . . . . . . . 51
Figure 4-7 RJ45 to DB9 Female Adapter (RS232) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Figure 4-8 RS422 to RS232 Converter Using the Terminal Box (RS422). . . . . . . . . . . . . . . . . 52
Figure 4-9 RS232 Serial Port Connection and Terminal Box RS422 . . . . . . . . . . . . . . . . . . . 53
Figure 4-10 RS232 Serial Port Connection, MX18 and the Terminal Box . . . . . . . . . . . . . . . . . 53
Figure 4-11 Ethernet Port Connections to MAXPRO-Net . . . . . . . . . . . . . . . . . . . . . . . . . 56
Figure 4-12 UltraKey Lite Login page. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Figure 4-13 System Configuration Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Figure 4-14 MAXPRO Configuration Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Figure 4-15 Serial Port Configuration Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Figure 4-16 IP Configuration Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Figure 4-17 DynKey Configuration Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Figure 5-1 Software Upgrade Warning Message . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69

UltraKey Lite Controller Installation and User Guide
Document 800-07422 Rev A 13
08/10
Tables
Table 1-1 UltraKey Lite Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Table 1-2 Shipping Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Table 2-1 LCD Menu Navigation During Set Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Table 2-2 VideoBloX Key Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Table 2-3 MAXPRO Key Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Table 3-1 Serial Port COM1 and COM2 Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . 33
Table 3-2 RJ45 Ethernet Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Table 3-3 Setting the Keyboard Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Table 4-1 Serial Port COM1 and COM2 Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . 49
Table 4-2 Terminal Box COM1 and COM2 Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . 52
Table 4-3 RJ45 Ethernet Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Table 4-4 Setting the Keyboard Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Table 5-1 HJC5000 UltraKey Lite Controller Default Settings. . . . . . . . . . . . . . . . . . . . . . . 67

14

Document 800-07422 Rev A 15
08/10
1
About this Document and the UltraKey Lite
In this section:
•Document Overview, page 15
•Finding More Information, page 16
•Typographical Conventions, page 16
•UltraKey Lite Specifications, page 17
•Shipping Checklist, page 18
•UltraKey Lite Port Connections and Descriptions, page 19
The UltraKey Lite (HJC5000) is a replacement for the Honeywell HEGSBLX controller and
is compatible with Honeywell VideoBloX and MAXPRO-Net Video Matrix Systems.
The UltraKey Lite has these modes available depending on the installation:
• MAXPRO: For use with MAXPRO-Net Matrix System installations.
• VideoBloX: For use with VideoBloX Matrix System installations.
Note This installation and user guide describes the Honeywell VideoBloX and
MAXPRO-Net Video Matrix mode installation and set-up. Future product and
documentation releases will include the Standalone mode for PTZ and DVR
functionality.
Document Overview
The following is included in this user guide:
• UltraKey Lite controller user instructions (Chapter 2).
• Installation/connection and configuration instructions specific to VideoBloX
(Chapter 3) and MAXPRO-Net (Chapter 4).
• System Administration and troubleshooting (Chapter 5).

16
About this Document and the UltraKey Lite
Finding More Information
Refer to the online literature library to access other electronic documents in PDF format
including data sheets, quick references, installation and user guides, specifications,
software and product notices: http://www.honeywellvideo.com. Also see the back cover
for international web sites and contact details.
Typographical Conventions
This document uses these typographical conventions:
Font What it represents Example
Use of an arrow
between items >
Use of an arrow between keys or tabs indicates
the order to select a menu item from the LCD or
a web browser. You may be using keys on the
controller or a mouse to click and select a tab on
a web browser
1. On the controller, press Alt > Clr to enter
the System Configuration: System Set
menu.
The System Set: Mode screen displays.
Lucida Values of editable fields that are mentioned in
the body text of the document for reference
purposes, but do not need to be entered as part
of a procedure.
The Time from field can be set to
Hours:Minute:Seconds.
Text strings displayed on the screen.
Syntax.
The message Unauthorized displays.
(object) entered
Swiss721 BT Bold Words or characters that are part of the task
process and identify a field and an action that
must be typed.
Enter the password 1234.
Menu titles and other items you select. Double-click Open from the File menu.
Buttons you click on a web browser to perform
actions.
Pressing a key on the keyboard.
Click Exit to close the program.
Press and hold Logon.
Courier Text that displays on the LCD screen The LCD menu IPAddr Changed displays.
Italic Placeholders: words that vary depending on the
situation.
user name
Cross-reference to external source. Refer to the System Administrator Guide.
Cross-reference within document. See Chapter 2, Installation.

UltraKey Lite Controller Installation and User Guide
Document 800-07422 Rev A 17
08/10
UltraKey Lite Specifications
Table 1-1 UltraKey Lite Specifications
Parameter Value
Power Requirements 10.8 to 13.2 VDC @ 1 Ampere (A) or POE (48 VDC, Class 3)
Connector Types 1×Ethernet (10Base-T, 100Base-TX) RJ45 with LED
1×RS232/422/485 RJ45 with LED
LCD Type: STN, Positive Image
Backlight: Blue-White
Characters: 122×32 Dots
USB Type: A
Version: USB1.1 (For USB PC Keyboard)
Compliance EN55022 for radiated and conducted emissions
Mechanical Dimensions: 408 mm (L) × 215 mm (W) × 105 mm (H)
Gross Weight: 3.2 kg
Cover material: ABS+PC (cool gray)
Environment Operating Temperature: -10 to +55 deg C
Storage Temperature: -40 to +75 deg C
Humidity: 0 to 95% RH (non-condensing)

18
About this Document and the UltraKey Lite
Shipping Checklist
The following is included with your UltraKey Lite Controller shipment. Use of accessories
is dependent on the type of installation. Ultrakey Lite can be connected to the matrix
system either by serial port or Ethernet RJ45 connections.
Table 1-2 Shipping Checklist
Quantity Part Use with...
1 Ultrakey Lite keyboard controller All installations.
1 Ultrakey Lite installation and user
guide
All installations.
1 box Power adapter with plugs for
100-240 VAC, 12 VDC, 50-60 HZ,
1 A, 12 W
Plug adapters depend on local electrical current. Four
models are included:
• CEE 7/16 (Europlug 2.5 A/250V unearthed)
• NEMA 1-15 (North American 15 A/125V ungrounded)
• BS1363 (British 13A /230-240V 50 Hz earthed and
fused)
• CPCS-CCC (Chinese 10 A/250V)/AS 3112 ; Australian
10 A/240V).
1 Connector adapter, RJ45 to DB9
male, for RS422
Backwards compatibility with VideoBloX and
VideoBloX Lite CPU installations. VideoBloX
master port.
2 Connector adapter, RJ45 to DB9
female, for RS232
Backwards compatibility with MAXPRO-Net CPU
installations.
2 RJ45 network cable, 2 meters All installations.
1 RJ45 cross-over Ethernet cable, 2
meters, blue
Used to connect a PC directly to the Controller for web
browser configurations.
1 RJ11 4X6 flat ribbon cable, 2 meters To connect from a MAXPRO and MX18 to the UltraKey Lite.
1 Function key overlay For use with VideoBloX installations.
1 Terminal box For additional device connection requirements.

UltraKey Lite Controller Installation and User Guide
Document 800-07422 Rev A 19
08/10
UltraKey Lite Port Connections and Descriptions
Figure 1-1 UltraKey Lite Port Connections
DC Power Port
Supports 12V (±10%) DC/1 A power input. Use the power adapter included with the
shipment and insert one of the four adapters based on your local power requirements.
Ethernet Port
Note Ethernet is used to connect to the controller web browser, MAXPRO-Net or
VideoBloX NetCPU.
• 10/100M Ethernet PoE (power over Ethernet) input. If PoE is the power input, it is
not recommended to connect this network with an outside building.
• TCP/IP protocol on the controller.
• For VideoBloX, the controller address range can be between 1 and 32. For
MAXPRO-Net, the address range can be between 1 and 99.
Power RJ45
Ethernet
RS232 and RS422/485
Serial port
USB
18 18
Pins numbered from right to left

20
About this Document and the UltraKey Lite
RS232, RS422/485 Serial Port
Note These ports are used to connect to MAXPRO-Net RS232 or RS422 and to
VideoBloX NetCPU, Standard CPU and Lite CPU RS422.
An isolated surge protection is suggested when using RS485/RS422 and when cabling
between buildings.
Note For MAXPRO net installations, COM1 (RS422) and COM2 (RS485) are
configured using the controller LCD menu and cannot be used at the same
time.
Note Serial port 1 can be either RS485 or RS422. Serial port 2 is only RS232.
Terminal Box
Use the terminal box RJ45 port and 8-pin terminal plug as required for compatibility and
connectivity options. It can be used to break out the RJ45 cable when wiring to existing
infrastructure is required.
Figure 1-2 Terminal Box Front and Back Ports
USB Port
The USB port is not used with VideoBloX or MAXPRO-net.
RJ45 EthernetRS232 DB9
Serial port
RS232 and RS422/485 8-pin
Terminal plug (pin numbers can
be assigned by user)
Table of contents
Other Honeywell Keyboard manuals