Hot Shot HS-1200 User Manual R2.1 | 6
READY TO PROGRAM YOUR CONTROLLER NOW?
Novus 4 480D setting ramp and soak times, temps and events.Novus 4 480D setting ramp and soak times, temps and events.
The oven comes with a factory installed USB port for programming the controller via a computer. Note:
Disconnect oven from power source before plugging in USB.
Press and hold the “P” button till PTOL appears, the use the “P” button to scroll thru parameter group.
GROUP PARAMETER
PSPO starting temp (control temp starting pt)
Pt1 time 1 (set desired temp)
PSP1 temp 1 (set desired temp)
PE1 event 1 (o or A-1 for alarm)
Pt2 time 2 (desired temp)
PSP2 temp 2 (set desired temp)
PE2 event 2 (o or A-1 for alarm)
Pt3 time 3 (set desired time)
PSP3 temp 3 (set desired temp)
PE3 event 3 (o or A-1 for alarm)
Pt4 time 4 (set desired time)
PSP4 temp 4 (set desired temp)
PE4 event 4 (o or A-1 for alarm)
Pt5 time 5 (set desired time)
PSP5 temp 5 (set desired temp)
PE5 event 5 (o or A-1 for alarm)
Pt6 time 6 (set desired time)
PSP6 temp 6 (set desired temp)
PE6 event 6 (o or A-1 for alarm)
Pt7 time 7 (set desired time)
PSP7 temp 7 (set desired temp)
PE7 event 7 (o or A-1 for alarm)
GROUP PARAMETER
Pt8 time 8 (set desired time)
PSP8 temp 8 (set desired temp)
PE8 event 8 (o or A-1 for alarm)
Pt9 time 9 (set desired time)
PSP9 temp 9 (set desired temp)
PE9 event 9 (o or A-1 for alarm)
Note: If any “PT” value is set to zero, the controller
will stop and end the sequence at the point.
rPT.P = number of times the controller will repeat
the sequence (after the Pt9 has timed out, it will
return to Pt1 and repeat the sequence)
Running in manual set point mode.
Press “P” once, E-prog = no press, press “P” again,
run = yes, you can manually adjust the green temp
set point and oven is in “run hold” mode with no
timers. Use the “^-v” keys to change set point.
N1030T controllers only
From the main start up screen, press “P” to cycle
through time and run-hold options.
Press “P” once for timer display, twice for “T1” timer
set, third time is run option.
On the “run” screen select “yes” to run hold, “no” to
remove run command or “F” to enable the function
key.
Once you have enable the “F” key, push and hold
the F key for a 3 count, run command will applied
and controller will run for the amount of time set
on “T1”, when this timer reaches zero value, the run