Installation
Theinstallationprocedureisillustratedin the rst pages
of this manual.
Theinstallationmustbedonebyaqualiedtechnician.
Electrical hook up
The mains voltage must match that given on the ratings
label inside the hood itself. If the hood has a power plug,
connect the hood to an easily accessible regulatory power
socket. If it does not (direct connection to the mains), or the
socketisnoteasilyaccessible,installatwo-poleregulatory
switch to enable total disconnection from the mains in case
of category III overvoltage, as required by the installation
regulations.
Caution! Always check that the mains cable is hooked
up properly and check that it operates correctly before
reconnecting the hood to the mains.
Air exhaust (for ducted units)
Connectthehoodto a ductandwallexhaustholeof a
diameterequaltothatoftheairoutletange.Usingasmaller
diameter tube and exhaust hole reduces the extraction
capacity of the hood and also increases its running noise.
The manufacturer is not liable for any consequences of
doing so.
!Usetheshortestductrequiredtoachievethepurpose.
!Useaductwithasfewbendsaspossible
!Avoid suddenly changing the diameter of the duct.
!The duct must have as smooth an inner surface as
possible.
!The duct must be made of regulatory material.
!Donotconnectthehoodtouescarryingcombustion
fumes from other equipment (boilers, chimneys, stoves,
etc.).
!Observe the instructions of the competent authorities in
relationtotheairexhaust.Theairbeing exhausted may not
beexhaustedinto a wall cavity unless the cavity inquestion
isspecicallyintendedforthispurpose.
!Equiptheroomwithairintakestopreventthehoodcreating
suction pressure in the interior (this must not exceed 0.04
mbar).
!The manufacturer is not liable for any consequences of
failure to observe these instructions.
Filter or ducted?
!Your hood is supplied as a ducted unit.
Ifyouwishtouseitasalterunit,youmustinstalltheproper
ACCESSORYKIT.
Note: If supplied with the hood, the accessory active
charcoallterunitmayalreadybeinstalled.
Instructionsfor transforming thehoodfrom the ductedtothe
lterversionaregiveninthismanual(see“Filterversion”).
Ducted version
Thehoodpuriestheairandexpelsitoutdoorsviaan
exhaustduct(dia.150mm)connectedtoitsoutletange.
The diameter of the exhaust tube must be equal to that of
theoutletange.
Caution! The exhaust duct is not supplied and must be
purchased separately.
When routed horizontally, the tube must be angled slightly
upwards (around 10°) to enable the air to be conveyed
outdoorsmoreeasily.Ifthehoodisttedwithcharcoal
lters,theymustrstberemoved.
Filter version
Thehoodpuriestheairandreturnsittotheroom.This
version of the hood requires installation of an accessory
activecharcoallterunit.
Thisversionrequiresanairdeector,areductionadapter
andthecharcoallter/s.Thetoptubemusthaveitsair
outlet slots uppermost.
*Only available in certain models
Technical data
Model Height
(cm) Width
(cm) Depth
(cm)
dia. of
exhaust tube
(cm)
PYRAMID 60cm 61-82 59.8 50 15/12
PYRAMID 70cm 61-82 69.8 50 15/12
PYRAMID 90cm 61-82 89.9 50 15/12
Please check the plate in order to verify the total
absorption and the light absorption
Power Voltage Cap Dimensions
Halogen 25 W 2 x 25 W 230 V G9 L40xØ14
Halogen 20 W 2 x 20 W 12 V G4 L30xØ10
LED *
Risk Group 1 according to Standard EN 62471
The model is in accordance with the following
EU directives::The hoods are conforming to the
following EC Directives:
•“Low voltage” Directive2006/95/EC(12-12-2006)
• “EMC” Directive 2004/108/EC (15-12-2004)
•URReference no. 66/2014 integrating Directive
no. 2009/125/EC.
Reference standard:
• EN 60704-2-13:2011; EN 60704-3:2006
• EN61591:1997;EN61591:1997/A1:2006;EN61591:1997/A2:2011;
EN 61591:1997/A11:2014
• EN 50564:2011