Hotspot FULHAM FHSAC1-UNV-40C-HL User manual

•
•
Output Wattage: 40W Max.
•
Universal Voltage: 120-277V , 50/60Hz~
•
Output Current: 250-1400mA
•
Output voltage range of 11-55V
General Specifications
Input Voltage
Input Current
Input Power
Standby Input Power
Output Current
Output Voltage Range
Output Power
Number of Output Channels
RFI/EMI
Output Type
Ambient Operating Temperature Range
Input Surge Protection
Protections
120-277VAC, 50/60Hz
0.43A @ 120VAC
54W
<0.85W
Constant Current
11-28VDC ( 250-1400mA ) , 11-40VDC ( 250-1000mA ) , 11-55VDC ( 250-730mA )
40W Max. ( Figure 1 )
1 Channel
FCC Part 15A Non-Consumer
LED Class 2
Line-Neutral 3kV , Line & Neutral-Gound 6kV , Ring Wave ANSI/IEEEC62.41
Input Current Protection
Output Open Circuit Protection
Output Short Circuit Protection
Output To Ground Short Circuit Protection
250-1400mA [ TPSB 100 ( Program Box ) , Figure 1 ] ; Record New Setting On 1"x0.5" Label
This Driver Will Operate The Following LED Modules: Any LED module designed to accept input voltage range of 11-55VDC and can operate
up to current of 250-1400mA.
Battery Type LiFePO4 6.4VDC (Part# FHSBATL2-3.2L)
Battery Capacity Available
Max. Case Temperature
3200mAh
Battery Recharge Time 12 Hours
Page 1 of 8
Driver Type
FHSAC1-UNV-40C-HL
SPECIFICATIONS
2023-956 Rev A
Power Factor >0.9
<20%
THD
5W or 10W @ Emergency Mode (Min. 180 Minutes @ 5W, Min. 90 Minutes @ 10W)
Sound Rating A
Over Temperature Protection
Overload Protection
Dimming Controller Type / Dimming Range 0-10V / 100% - 1%,0% ( Figure 2 ) / Custom Dimming Curve / Dimmed To Off
Service Life
Approvals / Class
50,000 hours
RoHS , cURus , CEC , Dry or Damp Locations
MECHANICAL DATA 100%-1%,0% LiFePO4 E313578
0°C to 48°C(32°F to 118.4°F)
85°C (185°F)
•
Compact case with side leads
MECHANICAL DATA
LED Driver with integrated emergency backup
Meets UL 924 & NFPA 101
•
Test Switch Remote Mounting Distance 20' (6m) Max.
Fulham extends a limited warranty to the original purchaser or first user for a period of 5 years @ Tc 63°C from the date of manufacture when properly
installed and operated under normal conditions of use. For complete terms and conditions, please refer to the Warranty Center at www.fulham.com.
Specifications subject to change without notice.
Type HL
•
MECHANICAL DATA
Case Tolerance=±0.02"
FHSAC1-UNV-40C-HL
5.96"
[151.5mm]
6.32"
[160.5mm]
5.53"
2.56"
[65mm]
Tc
0.59"
[15mm]
[140.4mm]
R0.08"
[2.1mm]
0.59"
[15mm]
1.14"
[29mm]
3.13"
[79.5mm]

Accessories
Page 2 of 8
Fulham extends a limited warranty to the original purchaser or first user for a period of 5 years @ Tc 63°C from the date of manufacture when properly
installed and operated under normal conditions of use. For complete terms and conditions, please refer to the Warranty Center at www.fulham.com.
Specifications subject to change without notice.
FHSAC1-UNV-40C-HL
SPECIFICATIONS MEC HANICAL DATA 100%-1%,0% LiFePO4 E313578
Wall Plate: FHSWLPWH
70.5
(2.78”)
115.5
(4.55”)
Ø12.7
(0.50”)
84
(3.31”)
1.“Charge push to Test”plate
2. (2) 6-32 x ½”LG mounting screws
Wall plate and screw color:
white with black lettering
0.06"[1.6mm]
Ø.54"[13.8mm]
0.31" Max.[8mm Max.]
Panel Thickness
Ø.472"[Ø12mm]
0.88"[22.4mm]
Ø.36"[Ø9.1mm]
LED Lamp
Ø.3"[Ø7.6mm]
Metal cap
Mounting hole: ø0.472" - 0.492"
[ø12mm-12.5mm]
Overall Switch Dimension
O-rin g Sea l
0.544"[13.82mm]
0.621"[15.78mm]
Bi-Color Wet Location Test Switch: FHS-TSTWL-BC
Test Switch Extension: FHS-EXT-48-TST
2023-956 Rev A

SPECIFICATIONS
Page 3 of 8
MECHANICAL DATA 100%-1%,0% LiFePO4 E313578
FHSAC1-UNV-40C-HL
Figure4Figure3
Figure5 Figure6
Figure2
Figure1
700
R-SETCurve
400
500
600
700
Io(mA)
200
300
0 4 8 12 16 20
ResistorValue(Kohm)
0-10VLinearDimmingCurve
40
60
80
100
oValue(%)
0
20
0 1 2 3 4 5 6 7 8 9 10
Io
DimmingVoltge(V)
0 1 2 3 4 5 6 7 8 9 10
60
80
100
e(%)
0-10VLogDimmingCurve
0
20
40
Io Value
DimmingVoltge(V)
800
1000
1200
1400
max) (mA)
200
400
600
Io(m
VovsIo(max)Curve( )
10 20 30 40 50
OutputVoltage(V)
90
82
84
86
88
Efficienc (%)
750mA
1000mA
1250mA
1400mA
80
20 25 30 35 40 45 50 55
OutputVoltage(V)
90
86
88
ncy (%)
750mA
1000mA
80
82
84
20 25 30 35 40 45 50 55
Effici n
OutputVoltage(V)
1250mA
1400mA
OutputVoltage(V)
Efficiency vs Output Voltage at 120Vac Efficiency vs Output Voltage at 230Vac
Fulham extends a limited warranty to the original purchaser or first user for a period of 5 years @ Tc 63°C from the date of manufacture when properly
installed and operated under normal conditions of use. For complete terms and conditions, please refer to the Warranty Center at www.fulham.com.
Specifications subject to change without notice.
2023-956 Rev A

WIRING DIAGRAMS
SPECIFICATIONS
Page 4 of 8
MECHANICAL DATA 100%-1%,0% LiFePO4 E313578
SELF DIAGNOSTIC INSTRUCTIONS / OPERATION:
FHSAC1-UNV-40C-HL
If Dip Switch 2 (Self-Diagnostic Switch) is set to the OFF position:
The self diagnostic feature is disable. A functionality test shall be manually conducted every thirty (30) days to ensure
the emergency LED light source illuminates as intended. A full discharge test shall be conducted once a year; the LED
light source shall illuminate for a minimum of ninety (90) minutes for the 10W load (Dip Switch 1 is set to the ON position)
or one hundred eighty (180) minutes for 5W load (Dip Switch 1 is set to the OFF position).
If Dip Switch 2 (Self-Diagnostic Switch) is set to the ON position:
The self diagnostic feature is enable .The emergency LED driver will conduct a self check for thirty (30) seconds every
thirty (30) days; and ninety (90) minutes or one hundred eighty (180) minutes self check every 12 months. After every self
check the LED indicator light will indicate a status signal. A single self-diagnostic test can be activated by pressing the test
switch three (3) times. Refer to Indicators Status Table for details.
When user toggle the Dip Switch, the LED indicator on Switch button would flash 3 times, 2.5S ON/0.5S OFF for Enabled,
while 0.5S ON/2.5S OFF for Disabled.
Fulham extends a limited warranty to the original purchaser or first user for a period of 5 years @ Tc 63°C from the date of manufacture when properly
installed and operated under normal conditions of use. For complete terms and conditions, please refer to the Warranty Center at www.fulham.com.
Specifications subject to change without notice.
NOTE: 1.The driver must be grounded.
2.Once assembly, installation or servicing is complete,
insert the two connectors of the battery cable.
FHSAC1-UNV-40C-HL
LED OUTPUT
CHANNEL
PINK( - )
PURPLE( + )
Un-Switched Line
WHT(COMMON)
YEL/BLK( L )
BLK( L )
Switched or
Un-Switched Line
LED OUTPUT LEAD
TEST SWITCH / LED INDICATOR
DIMMING
0-10V
LED MODULE WITH NTC
(NTC OPTIONAL)
LED MODULE
NTC INPUT LEAD
Ø
INPUT SIDE LENGTH
BLACK 12"[304.8mm]
WHITE 12"[304.8mm]
YEL/BLK 16"[406.4mm]
OUTPUT SIDE LENGTH
LED OUTPUT
BATTERY
CONNECTOR
8"[203.2mm]
10.8"[275mm]
TEST LEAD 8"[203.2mm]
PURPLE 12"[304.8mm]
PINK 12"[304.8mm]
Case Dimensions
Length 6.32"[160.5mm]
Width 3.13"[79.5mm]
Height 1.14"[29mm]
Note: Pink or Gray dimming wire
provided. use interchangeably.
BAT TERY CONNECTOR
2023-956 Rev A

SPECIFICATIONS
Page 5 of 8
MECHANICAL DATA 100%-1%,0% LiFePO4 E313578
FHSAC1-UNV-40C-HL
Figure7 Figure8
Figure9 Figure10
Figure11 Figure12
88
90
(%)
750mA
80
82
84
86
Efficienc
1000mA
1250mA
1400mA
20 25 30 35 40 45 50 55
OutputVoltage(V)
80
100
120
140
e(Khrs)
LifetimevsTcase
0
20
40
60
50 55 60 65 70 75 80 85
Lifetime
Tcase(°C)
6
8
10
(%)
THDVsOutputPower
277V/60Hz
230V/50Hz
0
2
4
20 25 30 35 40
THD(
OutputPower(W)
120V/60Hz
p ( )
80
90
100
110
IovsExt.NTCCurve
10
20
30
40
50
60
70
80
IoRatio(% )
0
0 2 4 6 8 10 12 14 16 18 20
ResistorofExt.NTConModule(Kohm)
60
70
80
90
100
110
tio (%)
IovsTcase(driver)
0
10
20
30
40
50
50 60 70 80 90 100
IoRat
Tcase(°C)
0.95
1.00
r
PowerFactorVsOutputPower
277V/60Hz
0.75
0.80
0.85
0.90
Power Factor
230V/50Hz
120V/60Hz
20 25 30 35 40
OutputPower(W)
Fulham extends a limited warranty to the original purchaser or first user for a period of 5 years @ Tc 63°C from the date of manufacture when properly
installed and operated under normal conditions of use. For complete terms and conditions, please refer to the Warranty Center at www.fulham.com.
Specifications subject to change without notice.
Efficiency vs Output Voltage at 277Vac
2023-956 Rev A

SPECIFICATIONS
Page 6 of 8
MECHANICAL DATA 100%-1%,0% LiFePO4 E313578
FHSAC1-UNV-40C-HL
TEST SWITCH OPERATIONS:
1. EM Test: Press and hold test button (>1s) to enter EM mode for testing in normal AC powered. Subsequent tests
can be performed after a minimum 20 Second delay in pressing the Test Switch.
2. Manual Self-Diagnostic(When Self-Diagnostic Enabled - Dip Switch 1 set to the ON position): After charging twelve
(12) hours or battery fully charged, quickly press the test button three (3) times within three (3) seconds to force the
controller to enter a Self-Diagnostic cycle. To quit the self-diagnostic cycle after engaged press and hold the test button
for ten (10) seconds.
TEST SWITCH INDICATOR STATUS:
Programming:
This driver can be programmed using the TPSB-100(E). Programming features include the following:
* Output Current: 250-1400mA
* Dimming Curve
* LED NTC Thermal Protection
LED Indicators Status EM Driver Status/Mode
• Solid Green System OK/AC OK(Self-diagnostic Enabled or Disabled).
• Slow Flashing Red, 4s on/1s off Battery not detected, check battery switch or connection.
• Flashing Red, 1s on/1s off Battery Failure, replace battery.
• Flashing Green, 1s on/1s off Self-Diagnostic test underway.
• Fast Flashing Red, 0.1s on/0.1s off Abnormal driver performance, replace driver.
• Very Slow Flashing Red, 4s on/4s off Over temperature.
• None. Both LEDs OFF Normal working in EM mode.
• Green/Red alternative flashing, 1s green/1s red. No load or output over voltage protection triggered.
Fulham extends a limited warranty to the original purchaser or first user for a period of 5 years @ Tc 63°C from the date of manufacture when properly
installed and operated under normal conditions of use. For complete terms and conditions, please refer to the Warranty Center at www.fulham.com.
Specifications subject to change without notice.
https://www.fulham.com/PDFs/SpecSheets/Fulham-Design-Guide-Programmable-Drivers.pdf
* For more detailed programming instructions please see our Programming Instructions and Design Guide found
on our website:

Programming Features
Output EM Power - 5W and 10W
https://www.fulham.com/PDFs/SpecSheets/Fulham-Design-Guide-Programmable-Drivers.pdf
* For more detailed programming instructions please see our Programming Instructions and Design Guide found
on our website:
Enable / Disable Self-Diagnosic
*
SPECIFICATIONS MEC HANICAL DATA 100%-1%,0% LiFePO4 E313578
FHSAC1-UNV-40C-HL
Page 7of 8
Fulham extends a limited warranty to the original purchaser or first user for a period of 5 years @ Tc 63°C from the date of manufacture when properly
installed and operated under normal conditions of use. For complete terms and conditions, please refer to the Warranty Center at www.fulham.com.
Specifications subject to change without notice.
2023-956 Rev A
Factory Defaults:
10W EM
Self-Diagnostics Enabled

SPECIFICATIONS
Page 8 of 8
MECHANICAL DATA 100%-1%,0% LiFePO4 E313578
FHSAC1-UNV-40C-HL
Important Safety Instructions
When using electrical equipment and this lighting device basic safety precaution should
be followed at all times including but not limited to the following:
·CAUTION: Do not mount near gas or electric heaters.
·IMPORTANT: An un-switched AC power source of 120VAC to 277VAC is required for the
·This device is designed for use in fixtures listed for dry and damp locations.
PLEASE READ CAREFULLY AND FOLLOW ALL INSTRUCTIONS FOR YOUR OWN SAFETY
·CAUTION: Make sure all electrical connections conform to the National Electrical Code and all applicable local
regulations.
·CAUTION: Battery is rechargeable LiFePO4 type and must be recycled or disposed of properly.
·CAUTION: Do not use this emergency driver with accessory equipment other than recommended by
manufacturer; failure to follow this may cause an unsafe condition. Servicing should only be performed
by qualified service personnel.
·CAUTION: Do not use this emergency driver for other than intended use.
·CAUTION: Equipment should be mounted in locations and at heights where it will not readily be subjected
to tampering by unauthorized personnel.
yellow/black and white leads.
·IMPORTANT: A switched or un-switched AC power source of 120VAC to 277VAC is acceptable
for the black lead only.
TESTING SYSTEM: The emergency battery requires a minimum charge time of one (1) hour before testing the circuit.
A minimum of twelve (12) hours is required for a full charge.
ASSEMBLY and FIELD INSTALLATION WIRING: WARNING: AC power must be off before proceeding with assembly,
installation or servicing of emergency driver. Additionally ensure that the battery is disconnected (Battery Switch set to OFF).
RATED EMERGENCY OPERATION: Ninety (90) minutes for the 10W load or one hundred eighty (180) minutes for the 5W
load. The 10W or 5W option is determined by the position of Dip Switch 1 (Emergency Power Selection Switch).
Fulham extends a limited warranty to the original purchaser or first user for a period of 5 years @ Tc 63°C from the date of manufacture when properly
installed and operated under normal conditions of use. For complete terms and conditions, please refer to the Warranty Center at www.fulham.com.
Specifications subject to change without notice.
IMPORTANT: In order to maintain proper operation and warranty coverage, the battery must be recharged once
per year prior to installation.
·CAUTION: REPLACE BATTERY ONLY WITH MODEL No: FHSBATL2-3.2L.
·ATTENTION: REMPLACER LA BATTERIE UNIQUEMENT PAR UNE BATTERIE: FHSBATL2-3.2L
2023-956 Rev A
Table of contents