Hovertech HOVERMATT PROS Air User manual

TABLE OF CONTENTS
Symbol Reference ..........................................................2
Intended Use and Precautions........................................3
Part Id - HoverMatt® PROS Air.........................................4
Product Specifications/Required Accessories..................4
Part Identification - HT-Air® Air Supply............................5
HT-Air® Keypad Functions ..............................................5
Air200G/Air400G Air Supplies........................................5
Instructions for Use .....................................................6-7
Cleaning and Preventive Maintenance ...........................8
Returns and Repairs........................................................9
User Manual
Visit www.HoverMatt.com for other languages
Patient Repositioning O-Loading System

PROS™ Air User Manual
2| HoverTech International HMPROSAirManual, Rev. A
Symbol Reference
CE MARKING OF CONFORMITY
UK MARKING OF CONFORMITY
AUTHORIZED REPRESENTATIVE
UK RESPONSIBLE PERSON
SWITZERLAND AUTHORIZED
REPRESENTATIVE
CAUTION / WARNING
ATTACH CONNECTING STRAP
DISPOSAL
FOOT END
IMPORTER
OPERATING INSTRUCTIONS
LATEX FREE
LOOP STYLE HANGER BAR
LOT NUMBER
MANUFACTURER
DATE OF MANUFACTURE
MEDICAL DEVICE
MODEL NUMBER
SINGLE PATIENT MULTIPLE USE
DO NOT LAUNDER
UNIQUE DEVICE IDENTIFIER
PATIENT WEIGHT LIMIT

HMPROSAirManual, Rev. A www.HoverMatt.com | 3
PROS™ Air User Manual
Intended Use and Precautions
INTENDED USE
The HoverMatt® PROS™ (Patient Repositioning O-Loading System) Air, is
used to assist caregivers with patient positioning (including boosting and
turning), lateral transfers, and proning using air. By providing pressure
relief of bony prominences to aide with Q2, reducing shear and friction
when repositioning, and enhancing microclimate management, the system
provides a solution to safely turn and reposition patients while reducing
caregiver strain.
The HoverTech Air Supply inflates the PROS Air to cushion and cradle the
patient, while air simultaneously escapes from the holes on the underside,
reducing the force needed to move the patient by 80-90%.
INDICATIONS
• Patients unable to assist in their own repositioning (including turning
and boosting) and lateral transfers.
• Patients that need Q2 turning for o-loading pressure.
• Patients that need to be placed in prone position.
• Patients whose weight or girth poses a potential health risk for the
caregivers responsible for repositioning or laterally transferring said
patients
CONTRAINDICATIONS
• Do not use with patients over the weight limit of 1200lbs.
• Do not use with patients who are experiencing thoracic, cervical or
lumbar fractures that are deemed unstable unless a clinical decision
has been made by your facility.
INTENDED CARE SETTINGS
• Hospitals, long term or extended care facilities.
PRECAUTIONS PROS AIR
• Caregivers must verify that all brakes have been engaged prior to
transfer.
• Use a minimum of two caregivers during lateral patient transfers.
• For in-bed positioning tasks, more than one caregiver may be needed.
• Never leave patient unattended on an inflated device.
• Use this product only for its intended purpose as described in this
manual.
• Only use attachments and/or accessories that are authorized by
HoverTech International.
• When transferring or positioning on a low air loss mattress, set the bed
mattress air flow to the highest level for a firm surface.
If there is any indication of damage, remove the PROS Air
from service and discard.
Side rails must be raised with one caregiver.
PRECAUTIONS AIR SUPPLY
• Not for use in the presence of flammable anesthetics or in a hyperbaric
chamber or oxygen tent.
• Route the power cord in a manner to ensure freedom from hazard.
• Avoid blocking the air intakes of the air supply.
• When using the PROS Air in the MRI environment, a 25 ft. specialty
MRI hose is required (available for purchase).
Reference product specific user manuals for
operating instructions.
Avoid electric shock. Do not open air supply.
In the OR – To prevent patient from slipping, always deflate the
HoverMatt and secure the patient and HoverMatt to the OR table
prior to moving the table into an angled position.

PROS™ Air User Manual
4| HoverTech International HMPROSAirManual, Rev. A
Part Identification – PROS Air
Hose Entries (2)
PROS Air
Material: Nylon Twill
Construction: Sewn
Width: 48.5" (123 cm)
Length: 78" (198 cm)
Model #: PROS-HM-KIT (Air Matt + HoverCover + pair of wedges) 3 per case*
Model #: PROS-HM-CS (Air Matt + HoverCover) 10 per case
LIMIT 1200 LBS/ 544 KG
*Wedge Pair Includes: 1 Wedge with Tail & 1 without Tail, Compressed
REQUIRED ACCESSORY:
Model #: HTAIR1200 (North American Version) – 120V~, 60Hz, 10A
Model #: HTAIR2300 (European Version) – 230V~, 50 Hz, 6A
Model #: HTAIR1000 (Japanese Version) – 100V~, 50/60 Hz, 12.5A
Model #: HTAIR2356 (Korean Version) – 230V~, 50/60 Hz, 6A
Model #: AIR200G (800 W) – 120V~, 60Hz, 10A
Model #: AIR400G (1100 W) – 120V~, 60Hz, 10A
Product Specifications/Required Accessories
Handles (under sides)
Connecting Straps (4)
Storage Pockets (4)
Turning Straps (4)
(Can also be used as
Transfer Handles)
HoverCover Holding Patch

HMPROSAirManual, Rev. A www.HoverMatt.com | 5
PROS™ Air User Manual
Air Filter
Cover
Hose
Nozzle
Hose
Hose Release Button
Control Panel Label
Carrying Handle/
Attachment Hook
Power
Cord
Strap
Power Cord
(US/UK/Euro)
WARNING: The HT-Air is not compatible with DC power supplies.
The HT-Air is not for use with the HoverJack Battery Cart.
HT-Air® Keypad Functions
Transfer
Speed
High
Adjustable/
Pressure
Setting
Transfer
Speed
Low
Standby (Amber LED)
Power IndicationAdjustable Speed
Indication
(Green Flashing LED)
Green LEDs
ADJUSTABLE: For use with HoverTech air-assisted positioning
devices. There are four dierent settings. Each press of the
button increases the air pressure and rate of inflation. The Green
Flashing LED will indicate the inflation speed by the number of
flashes (i.e. two flashes equals the second inflation speed).
All of the settings in the ADJUSTABLE range are substantially
lower than the HoverMatt and HoverJack settings. The
ADJUSTABLE function is not to be used for transferring.
The ADJUSTABLE setting is a safety feature that can be used
to ensure the patient is centered on HoverTech air-assisted
devices and to gradually accustom a patient who is timid or in
pain to both the noise and functionality of the inflated devices.
STANDBY: Used to stop inflation/air flow (Amber LED indicates
STANDBY mode).
HOVERMATT 28/34: For use with 28" & 34" HoverMatts and
HoverSlings.
HOVERMATT 39/50 & HOVERJACK: For use with 39" & 50"
HoverMatts and HoverSlings and 32" & 39" HoverJacks.
Part Identification – HT-Air® Air Supply
Air200G/Air400G Air Supplies
If using HoverTech’s Air200G or Air400G Air Supplies, press the grey
button on the top of the canister to initiate air flow. Press the button
again to stop air flow.

PROS™ Air User Manual
6| HoverTech International HMPROSAirManual, Rev. A
Instructions for Use – PROS Air
PLACING PRODUCT UNDER PATIENT LOG ROLLING TECHNIQUE
1. Open the product and place length-wise next to the patient.
2. Unfold the PROS Air furthest from the patient to the side of the bed.
3. Tuck the other side under the patient as far as possible.
4. Roll the patient onto their side toward the unfolded matt. Unroll the
rest of the matt from under the patient to cover the bed.
5. Place the patient back in a supine position. Straighten matt to remove
any wrinkles.
ATTACHING TO BEDFRAME
1. Remove corner Velcro connecting straps from pockets and loosely
attach to solid points on the bedframe (or to the headboard) to
reduce matt migration.
2. Repeat the process on the other three corners of the matt.
3. Before boosting, turning, proning, and/or transfers, disconnect
connecting straps from bed frame.
4. When straps are not in-use, store in pockets.
1. If using one caregiver, raise the siderails prior to matt inflation.
2. Press the variable speed button to ensure the patient is centered.
3. When confirmed patient is centered, press the 39” HoverMatt setting
on the air supply.
NOTE: If using the Air200G or Air400G, press the gray button to fully
inflate the PROS Air.
4. When matt is fully inflated, use the handles under the edge of the
matt to boost patient into proper placement on the bed.
5. Press the STANDBY button to stop airflow. Remove hose. Smooth out
wrinkles of matt.
6. Attach Velcro connecting straps to bedframe to keep matt in place
and reduce migration
REPOSITIONING/WEDGE PLACEMENT
1. If using one caregiver, raise the siderails prior to matt inflation.
2. Press the variable speed button to ensure the patient is centered.
3. When confirmed patient is centered, press the 39” HoverMatt setting
on the air supply.
NOTE: If using the Air200G or Air400G, press the gray button to fully
inflate the PROS Air.
4. When matt is fully inflated, use the handles under the edge of the
matt to center the patient on the bed.
5. Press the STANDBY button to stop airflow. Remove hose. Smooth out
wrinkles of matt.
6. Attach Velcro connecting straps to keep matt in place and reduce
migration.
Instructions for Use as an Air-Assisted Device
1. Patient should preferably be in a supine position.
2. Place PROS Air underneath patient using a log rolling technique.
3. Plug the HoverTech Air Supply power cord into an electrical outlet.
4. Insert the hose nozzle into either of two hose entries at foot end of
PROS Air and snap into place.
1. Wedge Placement (If using one caregiver, side rails must be raised)
a. To insert wedges, inflate PROS Air and hold the edge of the matt.
Place wedges between the bed and device.
b. Insert the tail of the wedge just under the patient’s thighs. Ensure
the back part of the wedge is elevated until the position is set, then
lower the wedge down to secure in place with the HoldFast™ foam.
c. Place the standard wedge to support the patient’s back about 1
hand’s width away from the tailed wedge. Ensure the back part
of the wedge is elevated until the position is set, then lower the
wedge down to secure in place with the HoldFast foam.
d. Pull the tail through to the other side of the patient to anchor
the wedge.
e. After wedges are placed, make sure the sacrum is not touching
the bed (floating). If it is, reposition wedges to ensure sacral o-
loading.
f. Deflate the matt and reconfirm the placement of the wedges.
BOOSTING
(To ease boosting eorts, place bed in Trendelenburg prior to boosting.

HMPROSAirManual, Rev. A www.HoverMatt.com | 7
PROS™ Air User Manual
REPOSITIONING/WEDGE PLACEMENT CONTINUED
2. Hygiene Turn, HoverCover™ Replacement, Wedge Placement (air turn)
a. With a caregiver on each side of the patient, fully inflate PROS Air.
Slide the patient in the opposite direction of the turn, slide them
as close to the edge of the bed as possible to ensure that when the
patient is repositioned, they will be centered on the bed.
b. To turn the patient on their side, the caregiver furthest from the
patient will gently push down on the PROS Air at the patient’s
shoulder and hip, while the turning caregiver gently pulls up on
the handles. Once the patient is turned on their side, the caregiver
receiving will stay with the patient while the turning caregiver
presses the STANDBY button to stop air flow.
c. If replacing the HoverCover or performing a hygiene turn, the
opposite caregiver will brace the patient on their side while the
turning caregiver will release the handles and hold onto the
patient’s hip and shoulder to stabilize the patient.
d. While the patient is turned, hygiene can be performed and
HoverCover removed and replaced.
e. Repeat on the other side before placing wedges.
f. Insert the tail of the wedge just under the patient’s thighs. Ensure
the back part of the wedge is elevated until the position is set, then
lower the wedge down to secure in place with the HoldFast™ foam.
g. Place the standard wedge to support the patient’s back about 1
hand width away from the tailed wedge. Ensure the back part
of the wedge is elevated until the position is set, then lower the
wedge down to secure in place with the HoldFast foam.
h. Return patient to supine position.
i. Pull the tail through to the other side of the patient to anchor the wedge.
j. After wedges are placed, make sure the sacrum is not touching
the bed (floating). If it is, reposition wedges to ensure sacral o-
loading
3. Wedge Placement with a Ceiling or Portable Lift (Single Caregiver)
a. Raise the side rails on the opposite side of the bed the patient
will be turned toward. Ensure the patient is centered and slide
the patient in the opposite direction of the turn using either the
sling to lift or a manual technique. This will allow the patient to be
centered on the bed when repositioned on the wedges.
b. Attach the shoulder and hip turning straps of the PROS Air to the
hanger bar which should be parallel to the bed. Raise the lift to
initiate the turn.
c. Insert the tail of the wedge just under the patient’s thighs. Ensure
the back part of the wedge is elevated until the position is set, then
lower the wedge down to secure in place with the HoldFast foam.
d. Place the standard wedge to support the patient’s back about 1
hand’s width away from the tailed wedge. Ensure the back part
of the wedge is elevated until the position is set, then lower the
wedge down to secure in place with the HoldFast foam.
e. After the wedges are placed, lower the patient onto the wedges,
ensure straps are not underneath the PROS Air.
f. Pull the tail through to the patient’s other side until taught. Check
wedge placement by placing your hand between the wedges,
confirming the sacrum is not touching the bed. If it is, reposition
wedges to ensure sacral o-loading.
LATERAL TRANSFER
1. Ensure that transfer surfaces are as close as possible and lock
all wheels.
2. If possible, transfer from a higher surface to a lower surface.
3. Press the variable speed button to ensure the patient is centered.
4. When confirmed patient is centered, press the 39” HoverMatt setting
on the air supply.
NOTE: If using the Air200G or Air400G, press the gray button to fully inflate
the PROS Air.
5. Push PROS Air at an angle, either headfirst or feetfirst. Once half-way
across, opposite caregiver should grasp closest handles and pull to
desired location.
6. Ensure patient is centered on receiving equipment prior to deflation.
7. Turn o air supply and employ the bed/stretcher rails.
8. Remove connecting straps from pockets and loosely attach to solid
points on bed frame if transferring back to bed.
NOTE: For use with patients of size, two air supplies may be used for
inflation.
PRONE
1. Ensure brakes are locked. Multiple caregivers will be needed for this
task.
2. Be sure patient is centered on the product prior to movement.
3. Inflate the PROS Air. Slide patient over to one side of the bed to
ensure room for the turn.
4. Place another HoverCover, positioning devices or pillows, and PROS
Air on top of the patient. Fold matt down to shoulder level keep face
exposed.
5. Roll the two PROS Air matts together toward the patient to tightly
cocoon the patient.
6. With a firm grasp on the rolled matts, turn the patient onto their side.
Caregivers on opposite sides should exchange hand positions (hands
on top should switch with hands on bottom).
7. Continue with turn after hand positions are switched. Unroll the matts
and remove the top PROS Air and HoverCover.
8. Position patient per facility protocol.

PROS™ Air User Manual
8| HoverTech International HMPROSAirManual, Rev. A
Cleaning and Preventive Maintenance
PROS AIR CLEANING
If soiled, the PROS Air may be wiped down with disinfectant wipes or a
cleaning solution used by your hospital for medical equipment disinfec-
tion. A 10:1 bleach solution (10 parts water: one part bleach) may also be
used.
NOTE: Cleaning with bleach solution may discolor fabric.
To help keep the PROS Air clean, HoverTech International recommends the
use of the HoverCover™ Disposable Absorbent Cover. Whatever the patient
is lying on to keep the hospital bed clean may also be placed on top of the
PROS Air.
The Single-Patient Use PROS Air is not intended to be laundered.
AIR SUPPLY CLEANING AND MAINTENANCE
See air supply manual for reference.
NOTE: CHECK YOUR LOCAL/STATE/FEDERAL/INTERNATIONAL GUIDELINES
BEFORE DISPOSAL.
PREVENTIVE MAINTENANCE
Prior to use, a visual inspection should be performed on the
PROS Air
to
ensure that there is no visible damage that would render the PROS Air un-
usable. The
PROS Air
should have all of its straps and handles (reference the
manual for all appropriate parts). If any damage is found that would cause
the system not to function as intended, the
PROS Air
should be removed
from use and discarded.
INFECTION CONTROL
The Single-Patient Use PROS Air eliminates the possibility of cross-contami-
nation and the need for laundering.
If the PROS Air is used for an isolation patient, the hospital should employ
the same protocols/procedures it utilizes for the bed mattress and/or for
linens in that patient room.

HMPROSAirManual, Rev. A www.HoverMatt.com | 9
PROS™ Air User Manual
In case an adverse event in relation to the device,
incidents should be reported to our authorized
representative. Our authorized representative will
forward information to the manufacturer.
Etac Ltd.
Unit 60, Hartlebury Trading Estate,
Hartlebury, Kidderminster,
Worcestershire, DY10 4JB
+44 121 561 2222
Promefa AG
Kasernenstrasse 3A
Hartlebury, Kidderminster,
8184 Bachenbülach, CH
+41 44 872 97 79
HoverTech International
4482 Innovation Way
Allentown, PA 18109
www.HoverMatt.com
Info@HoverMatt.com
These products comply with the standards applicable
for Class 1 products in the Medical Device Regulation
(EU) 2017/745 on medical devices.
Returns and Repairs
All products being returned to HoverTech International (HTI) must have
a Returned Goods Authorization (RGA) number issued by the company.
Please call (800) 471-2776 and ask for a member of the RGA Team who will
issue you an RGA number. Any product returned without an RGA number
will cause a delay in the repair time.
Returned products should be sent to:
HoverTech International
Attn: RGA # ___________
4482 Innovation Way
Allentown, PA 18109
For product warranties, visit our website:
https://hovermatt.com/standard-product-warranty/
For European companies, send returned products to:
Attn: RGA #____________
Kista Science Tower
SE-164 51 Kista, Sweden
CEpartner4U, ESDOORNLAAN 13,
3951DB MAARN, THE NETHERLANDS.
www.cepartner4u.com

4482 Innovation Way
Allentown, PA 18109
800.471.2776
Fax 610.694.9601
www.HoverMatt.com
Info@HoverMatt.com
This manual suits for next models
2
Table of contents
Other Hovertech Indoor Furnishing manuals
Popular Indoor Furnishing manuals by other brands

Vivo
Vivo DESK-AC08PG instruction manual

Mansion schools
Mansion schools PT-72 Series Assembly instructions

U-Line
U-Line H-1209 Assembly

Cheyenne Products
Cheyenne Products BH17-084-097-37 Assembly instructions

FX Cabinets Warehouse
FX Cabinets Warehouse Lazy Susan Series Assembly instructions

TUHOME Furniture
TUHOME Furniture MONTENEGRO MLA4439 Assembly instructions