manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Howard
  6. •
  7. Landscape Lighting
  8. •
  9. Howard DTDU-35LED-41-MV User manual

Howard DTDU-35LED-41-MV User manual

Popular Landscape Lighting manuals by other brands

LIGMAN ALDO 4 installation manual

LIGMAN

LIGMAN ALDO 4 installation manual

Intex SL1006 owner's manual

Intex

Intex SL1006 owner's manual

LED Group ROBUS R2IN13W quick start guide

LED Group

LED Group ROBUS R2IN13W quick start guide

Patriot Lighting 343-1484 installation manual

Patriot Lighting

Patriot Lighting 343-1484 installation manual

LIGMAN JET 44 installation manual

LIGMAN

LIGMAN JET 44 installation manual

Hess SERA G: SERA S Installation and operating instructions

Hess

Hess SERA G: SERA S Installation and operating instructions

LIGMAN MALTA 1 installation manual

LIGMAN

LIGMAN MALTA 1 installation manual

Saxby Lighting Islay 68784 Instruction leaflet

Saxby Lighting

Saxby Lighting Islay 68784 Instruction leaflet

LIGMAN EU-10016-3 installation manual

LIGMAN

LIGMAN EU-10016-3 installation manual

LIGMAN KI-60475 installation manual

LIGMAN

LIGMAN KI-60475 installation manual

Cooper Lighting McGraw-Edison ZD Credenza specification

Cooper Lighting

Cooper Lighting McGraw-Edison ZD Credenza specification

Cooper Lighting Generation CLB25MWW5C373 Specification sheet

Cooper Lighting

Cooper Lighting Generation CLB25MWW5C373 Specification sheet

Malibu Boats CM110P instructions

Malibu Boats

Malibu Boats CM110P instructions

AMP Lighting OrchardPro APL-3018-B-BZ Installation & maintenance guide

AMP Lighting

AMP Lighting OrchardPro APL-3018-B-BZ Installation & maintenance guide

Cooper Lighting Invue 42 - 175W Specification sheet

Cooper Lighting

Cooper Lighting Invue 42 - 175W Specification sheet

ABBA SPB12 installation guide

ABBA

ABBA SPB12 installation guide

Techmar Garden Lights GILVUS + manual

Techmar

Techmar Garden Lights GILVUS + manual

LIGMAN RADO 1 installation manual

LIGMAN

LIGMAN RADO 1 installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1
Rev. 5/6/2014
DTDU
LED Dusk-to-Dawn
Utility-grade
INSTALLATION INSTRUCTIONS
For models:
DTDU-35LED-41-MV
This model number does not include a mounting arm, photoelectric control.
Warning
Please read instructions carefully before
attempting to install fixture and retain instructions
for future reference.
Caution: To avoid electrical shock hazard.
• Turn off the electricity before installing or
servicing this fixture.
• Electrical connections need to comply with
National Electric Code and Local Electric Code.
• The fixture should be installed by a qualified
electrician.
General Safety Information
1. Disconnect power during installation and
before servicing.
2. Risk of Fire: Product is for outdoor installation
and use only.
3. To avoid the risk of fire or shock, this fixture
must be wired in accordance with the National
Electric Code and applicable local codes or
ordinances.
4. All work should be performed by a qualified
electrician.
5. To ensure personal safety, proper grounding is
required.
6. Do not touch the yellow portion of the LED
when removing the acrylic refractor. Damage
may occur.
WALL MOUNTING
Note: Assure that fixture is mounted to a structurally
sound surface that will support the fixture.
1. Select a location on a structurally secure wall or
pole, minimum 4 feet from the ground.
2. Place mounting section of fixture onto desired
mounting surface, mark and drill holes for
mounting.
3. This fixture can be mounted with three lag screws
which are provided. (Fig. 1, #14).
4. Install the two bottom lag screws first.
5. Place the fixture on the two bottom lag screws and
install the top lag screw.
6. Tighten the top lag screw first and then tighten the
remaining lag screws.
FIXTURE WIRING/INSTALLATION
Note: Connect fixture to supply wires, make sure power
is off.
1. Press stainless steel springs (Fig. 1, #22) outward to
release cover plate (Fig. 1, #24).
2. Feed supply wires through arm and make wiring
connections in the fixture.
3. Connect the incoming power lead wires to terminal
block (Fig. 1, #13) black to black and white to white.
Route lead wires through mounting arm, form a drip
loop, and connect lead wires to power source.
4. Ensure that the power supply voltage and luminaire
voltage ratings match.
5. The fixture must be grounded. Attach ground lead to
ground lug on terminal block (Fig. 1, #13).
6. For wall mount applications, secure the wall mount
cover plate (Fig. 1, #20) by removing the fitter clamp
(Fig. 1, #21), inserting wall mount cover plate (Fig.
1, #20), inverting the fitter clamp (Fig. 1, #21), and
securing with two washers (Fig. 1, #36) and two
screws (Fig. 1, #10).
7. Install shorting cap (Fig. 1, #1) or photoelectric
control by inserting plug into receptacle and twist
until locking in position. Ensure Photocontrol is rated
for the same voltage as the luminaire.
2
Rev. 5/6/2014
DTDU
LED Dusk-to-Dawn
Utility-grade
INSTALLATION INSTRUCTIONS
For models:
DTDU-35LED-41-MV
This model number does not include a mounting arm, photoelectric control.
Input voltage: 120-277v 50/60Hz
Color Temperature: 4100K
Shorting Cap Included
Consult Factory for Photoelectric Control ordering and specified voltage.
Technical Specifications
Figure 1
1
2
3
4
5
6
7
8
9
NO. DESCRIPTION QTY
Shorting cap 1
Ball screws 1
Photocell socket (Top) 1
Screws 9
Top Cover 1
Photocell socket (Bottom) 1
Gasket 1
Screws 5
Driver 1
10 Screws 2
11 Housing 1
12 Water gasket 1
13 Terminal block 1
14 Lag screw 3
15 Heat shrink sleeve 1
16 MOV 3
17 Thermal fuse 1
18 Cable 3
19 PCB 1
20 Wall mount cover plate 1
21 Fitter clamp 1
22 Stainless spring 2
23 Screw with washer 3
24 Cover plate 1
25 Tether cord 1
26 Acrylic refractor 1
27 Gasket 1
28 Refractor 1
29 Ball screws 3
30 LED cover 1
31 LED 1
32 Screw 1
33 Screw 4
34 C4 terminal 4
35 C5 terminal 1
36 Washer 2
1
2
3
4
5
6
7
8
9
10
11
12
13
29
14
15
16
17
18
19
21
20
22
23
24
25 23
35
34
33
32
31
30
29
28
8
27
26
436
1
Rev. 5/8/2014
DTDU
LED Dusk-to-Dawn
Utility-grade
INSTALLATION INSTRUCTIONS
For models:
DTDU-48-LED-41-MV
This model number does not include a mounting arm, photoelectric control.
Warning
Please read instructions carefully before
attempting to install fixture and retain instructions
for future reference.
Caution: To avoid electrical shock hazard.
• Turn off the electricity before installing or
servicing this fixture.
• Electrical connections need to comply with
National Electric Code and Local Electric Code.
• The fixture should be installed by a qualified
electrician.
General Safety Information
1. Disconnect power during installation and
before servicing.
2. Risk of Fire: Product is for outdoor installation
and use only.
3. To avoid the risk of fire or shock, this fixture
must be wired in accordance with the National
Electric Code and applicable local codes or
ordinances.
4. All work should be performed by a qualified
electrician.
5. To ensure personal safety, proper grounding is
required.
6. Do not touch the yellow portion of the LED
when removing the acrylic refractor. Damage
may occur.
WALL MOUNTING
Note: Assure that fixture is mounted to a structurally
sound surface that will support the fixture.
1. Select a location on a structurally secure wall or
pole, minimum 4 feet from the ground.
2. Place mounting section of fixture onto desired
mounting surface, mark and drill holes for
mounting.
3. This fixture can be mounted with three lag screws
which are provided. (Fig. 1, #14).
4. Install the two bottom lag screws first.
5. Place the fixture on the two bottom lag screws and
install the top lag screw.
6. Tighten the top lag screw first and then tighten the
remaining lag screws.
FIXTURE WIRING/INSTALLATION
Note: Connect fixture to supply wires, make sure power
is off.
1. Press stainless steel springs (Fig. 1, #22) outward to
release cover plate (Fig. 1, #24).
2. Feed supply wires through arm and make wiring
connections in the fixture.
3. Connect the incoming power lead wires to terminal
block (Fig. 1, #13) black to black and white to white.
Route lead wires through mounting arm, form a drip
loop, and connect lead wires to power source.
4. Ensure that the power supply voltage and luminaire
voltage ratings match.
5. The fixture must be grounded. Attach ground lead to
ground lug on terminal block (Fig. 1, #13).
6. For wall mount applications, secure the wall mount
cover plate (Fig. 1, #20) by removing the fitter clamp
(Fig. 1, #21), inserting wall mount cover plate (Fig.
1, #20), inverting the fitter clamp (Fig. 1, #21), and
securing with two lock washers (Fig. 1, #36) and two
screws (Fig. 1, #10).
7. Install shorting cap (Fig. 1, #1) or photoelectric
control by inserting plug into receptacle and twist
until locking in position. Ensure Photocontrol is rated
for the same voltage as the luminaire.
2
Rev. 5/8/2014
DTDU
LED Dusk-to-Dawn
Utility-grade
INSTALLATION INSTRUCTIONS
For models:
DTDU-48-LED-41-MV
This model number does not include a mounting arm, photoelectric control.
Input voltage: 120-277v 50/60Hz
Color Temperature: 4100K
Shorting Cap Included
Consult Factory for Photoelectric Control ordering and specified voltage.
Technical Specifications
Figure 1
NO. DESCRIPTION QTY
1 Shorting cap 1
2 Ball screws 1
3 Photocell socket (Top) 1
4 Screws 9
5 Top Cover 1
6 Photocell socket (Bottom) 1
7 Gasket 1
8 Screws 6
9 Driver 1
10 Screws 2
11 Housing 1
12 Water gasket 1
13 Terminal block 1
14 Lag screw 3
15 Heat shrink sleeve 1
16 MOV 3
17 Thermal fuse 1
18 Cable 3
19 PCB 1
20 Wall mount cover plate 1
21 Fitter Clamp 1
22 Stainless spring 2
23 Screw with washer 3
24 Cover plate 1
25 Tether cord 1
26 Acrylic refractor 1
27 Gasket 1
28 Refractor 1
29 Ball screws 3
30 LED cover 1
31 LED 1
32 Screw 1
33 Screw 2
34 C4 terminal 4
35 C5 terminal 1
36 Lock washer 2
1
2
3
4
5
6
7
8
9
10
11
12
13
29
14
15
16
17
18
19
21
20
22
23
24
25 23
35
34
33
32
31
30
29
28
8
27
26
436
8