Hold the control unit and the water cartridge
in both hands with the alignment marks on
the side facing yourself.
Put the control unit on the water cartridge
with its four clasps embedded into the
corresponding clasps of the water cartridge
Forward sliding push the control unit with
the alignment marks aligned to let both parts
locked together.
3. Principle of operation
The displayed humidity value is the humidity value measured by the built-in humidity sensor
plus the calibration value. When the displayed humidity value is less than the humidity setting
value, the built-in fan runs to blow the moist air in the water cartridge into the humidor. The fan
stops when the displayed humidity value is equal to or greater than the humidity setting value.
4. Setting
There are three keys on the control unit as shown in the figure below. The keys are used to set
the humidity setting value and humidity calibration value. The parameters set by the user are
stored in the microprocessor of the control unit and will not be lost even power off.
Humidity Setting Value,The user can set the demanded humidity value. The factory
setting is 70%RH. The value is adjustable in the range of 60%RH to 80%RH. Press the key
‘▲’ or the key ‘▼’, the value will be displayed on LED and changed. The value will be
saved and the humidifier will exit the setting without any key operation for more than 3
seconds, .
Humidity calibration value, Key ‘C’ is for calibration. You may set calibration value to
improve the accuracy. The factory setting calibration value is zero. Click key ‘C’ and you
will see the calibration value displayed on LED, within 3 seconds, press Key ‘▲’ or ‘▼’ to
increase or decrease the calibration value within a range of -5.0 to +5.0.
For example, if the displayed humidity value is 2%RH higher than the actual environmental
humidity value, you may set calibration value as -2.0 , and then the displayed humidity value
will equal to the measured humidity value by sensor plus the calibration value -2.0.
5. Applicability
The difference between S1 & M1 is the height of the water cartridge and the length of the
ribbon cable. S1 is with size of 6” (153m) Length, 2” (50mm) Width , 2.3” (59mm) Height,
suitable for a desktop humidor.
M1 is with size of 6” (153m) length, 2” (50mm) Width , 3.3” (84mm) Height, suitable for a